Preconnected adult and paediatric AED defibrillator electrode for Nihon Kohden Cardiolife 2100, 2150K, 2151K and 2152K – Pair of compatible pads

Pair of preconnected adult/paediatric electrodes (lead-out) compatible with the Nihon Kohden automatic defibrillators of the Cardiolife AED 2100, AED 2150K, AED 2151K and AED 2152K family. The anti-shock safety connector is accessible from the outside of the pouch, so the AED remains ready for analysis and discharge in seconds. Disposable multifunction electrodes of 1 mm medical foam (FOAM) with low-impedance conductive adhesive gel, supporting up to 50 discharges at 360 J and ECG monitoring for up to 24 h. A single pair covers adults and the paediatric population above 10 kg: the energy reduction in paediatric mode is activated with the AED’s own switch. Medical device class IIb, latex-free and phthalate-free, approximate service life of 30 months.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7948UW

Description

1. Commercial Introduction

Ensure your defibrillation point remains operational with this pair of pre-connected adult/paediatric multifunction electrodes, designed as a compatible consumable for the automatic defibrillators (AED) Nihon Kohden from the Cardiolife AED 2100, AED 2150K, AED 2151K and AED 2152K family. The pre-connected configuration (external cable or lead-out) keeps the cable and connector accessible from outside the sealed pouch, so the device is ready for analysis and shock delivery in seconds, without needing to open the packaging until the moment of use: a decisive advantage in the management of cardiac arrest. It is the ideal solution for emergency services, companies with an AED, sports centres, schools, industrial estates and any public access space that requires fast, reliable and cost-optimised replacement.

2. Technical explanation of the equipment and procedure

The disposable multifunction electrodes allow, with a single pair of adhesive pads: external transthoracic defibrillation, synchronized cardioversion, transcutaneous cardiac pacing and ECG monitoring. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the 1 mm medical foam (FOAM) backing and the internal metal foil guarantee uniform current distribution with minimal risk of burns.

As it is an adult/paediatric model, the same pair of electrodes works for patients over 10 kg (over 12 months): on Nihon Kohden Cardiolife devices, the energy switching is performed using the physical ‘adult/paediatric’ switch on the defibrillator itself, which automatically reduces the shock in paediatric mode. The shock-proof connector is inserted into the device socket following the anatomical diagrams on the packaging. It is a single-use product: it must be replaced after each use or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Product type Disposable adult/paediatric multifunction electrodes, pre-connected (lead-out)
Compatibility Nihon Kohden Cardiolife AED 2100, AED 2150K, AED 2151K and AED 2152K
Population Adults and paediatric \u003E 10 kg (\u003E 12 months); contraindicated in children under 12 months / \u003C 10 kg
Functions Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h)
Backing material Medical foam (FOAM) 1 mm thick; conductive metal foil
Conductive gel Low-impedance conductive adhesive gel
Connection type Shock-proof safety connector, accessible from outside the pouch (pre-connected / lead-out)
Number of shocks supported 50 shocks at maximum power (360 J) — typical value for the adult/paediatric series
Total / active area Total area ≈ 148 cm² and active area ≈ 95 cm² per electrode in adult configuration (typical value for the family)
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch (10 pairs per box)
Classification Medical device class IIb (EU Regulation 2017/745 – MDR; Directive 93/42/EEC)
Use Single-use, disposable, non-sterile
Exempt materials Latex-free and phthalate-free
Shelf life Approx. 30 months from the date of manufacture; expiry date indicated on the packaging
Storage Dry place, +5 °C to +35 °C; operation from 0 °C to +50 °C
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1 and 60601-2-4; ISO 10993-10

Note: the active area and number of shocks fields for the adult/paediatric series (≈ 95 cm² active area per electrode in adult mode and 50 shocks up to 360 J) correspond to typical values for the EuroDefiPads family; confirm with the Cahnos technical department for this reference before tendering.

4. Equivalences and Cross-References

This product is a compatible consumable for Nihon Kohden defibrillators, not an original spare part from the device manufacturer: the connector and monitoring system are proprietary to Nihon Kohden, so replacing the original pad with a compatible accessory must always be validated against the device’s technical data sheet and IFU. The original device manufacturer references that this electrode functionally covers are:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable adult/paediatric pad for Cardiolife AED (original equipment) P-740K Comparable by category (not interchangeable 1:1) Covers AED-2100K, 2150K, 2151K, 2152K, AED-3100 and TEC-5500/5600/7600/7700/8300 series (official IFU P-740K); 1.5 m cable. Factory original: connector, gel and labelling specific to Nihon Kohden. Reference confirmed at authorised manufacturer distributors.
Nihon Kohden Preconnected disposable adult/paediatric electrode (original equipment) P-530K Comparable by category (not interchangeable 1:1) Original preconnected variant listed as an option for the AED-2100K and for the AED-3100; the electrodes remain connected to the AED in standby. Reference confirmed at authorised manufacturer distributors.

There is no equivalence table validated by Nihon Kohden that authorises replacing the P-740K/P-530K references with third-party consumables: any comparison must be understood as comparable at category level, not interchangeable 1:1, and must be confirmed with the technical department before use in tendering. The correspondence of this SKU (F7948UW) with the official Nihon Kohden construction is not published by the equipment manufacturer.

5. Selection tips and variants of interest

If your AED is a Nihon Kohden Cardiolife AED 2100, AED 2150K, AED 2151K or AED 2152K and you serve the general population (adults and children), this pair of preconnected adult/paediatric electrodes is the most versatile option: a single pair of pads covers both populations and the paediatric energy is selected with the device switch, without the need for an additional set. For AED fleets or high-volume centres, manage stock rotation by expiry (approx. 30 months) and always replace the electrode after use or expiry. As variants of interest in the Cahnos catalogue, consider the preconnected lead-out variant for the same Nihon Kohden platform in models 2100, 2150K and 2151K (SKU F7989UW), the radiotransparent version for Nihon Kohden equipment (F7761U) if your centre performs imaging procedures, or the preconnected version for the Mediana and Tecno-Gaz brands (F7986UW) if you have other AEDs. Consult the Cahnos technical department to confirm exact compatibility with your defibrillator model before formalising large-volume orders or tenders.

Additional information

Product type

Disposable multifunction adult/paediatric pre-connected electrode (lead-out)

Compatibility

Nihon Kohden Cardiolife AED 2100, AED 2150K, AED 2151K and AED 2152K

Population

Adults and paediatric u003E 10 kg (u003E 12 months); contraindicated in children under 12 months / u003C 10 kg

Functions

Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h)

Backing material

Medical foam (FOAM) 1 mm thick; conductive metal foil

Gel material

Low-impedance conductive adhesive gel

Connector

Shock-proof safety, pre-connected (lead-out), accessible without opening the pouch

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch (10 pairs per box)

Classification

Medical device class IIb (EU MDR 2017/745; Directive 93/42/EEC)

Use

Single-use, disposable, non-sterile

Shelf life

Approx. 30 months from the date of manufacture; expiry date indicated on the packaging

Storage

Dry place, +5 °C to +35 °C; operation from 0 °C to +50 °C

Exempt materials

Latex-free and phthalate-free

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1 and 60601-2-4; ISO 10993-10

Manufacturer reference

Nihon Kohden P-740K / P-530K (original equipment parts, not 1:1 interchangeable)

Conductive gel

Low-impedance conductive adhesive gel

Connection type

Shock-proof safety connector, pre-connected (accessible without opening the pouch)

Number of shocks

50 shocks at maximum power (360 J) — typical value for the adult/paediatric series

Reviews

There are no reviews yet.

Be the first to review “Preconnected adult and paediatric AED defibrillator electrode for Nihon Kohden Cardiolife 2100, 2150K, 2151K and 2152K – Pair of compatible pads”

Your email address will not be published. Required fields are marked *