Pre-connected adult and paediatric AED defibrillator electrode (lead-out) for Nihon Kohden Cardiolife AED 2100, 2150K and 2151K – Pair of compatible multifunction pads

Pair of pre-connected multifunction adult/paediatric electrodes (lead-out) compatible with the automatic defibrillators Nihon Kohden of the family Cardiolife AED 2100, 2150K and 2151K (according to the accessory manufacturer’s catalogue, also listed for the 2152K). Designed for external defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h), with an anti-shock safety connector accessible from the outside of the pouch for immediate connection without opening the package. A single pair covers adults and the paediatric population above 10 kg: the energy reduction is activated with the adult/paediatric switch on the AED itself. Low-impedance conductive adhesive gel and medical foam backing, free from latex and phthalates, single-use medical device, class IIb.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7989UW

Description

1. Commercial Introduction

Ensure the operability of your defibrillation point with this pair of preconnected adult/paediatric multifunction electrodes, designed for the automated external defibrillators (AED) of the brand Nihon Kohden from the Cardiolife AED 2100, 2150K and 2151K family (the accessory manufacturer also lists them for the 2152K). Their lead-out or preconnected configuration keeps the cable and connector accessible from the outside of the sealed pouch, so the device is ready for analysis and shock delivery without opening the packaging until the moment of use: a decisive advantage in the management of cardiorespiratory arrest in emergency services, workplaces, industrial estates, schools and public spaces with AEDs.

2. Technical explanation of the equipment and procedure

The disposable multifunction electrodes allow, with a single pair of adhesive pads: external transthoracic defibrillation, synchronised cardioversion, transcutaneous cardiac pacing and ECG monitoring. Their low-impedance adhesive conductive gel ensures stable adhesion and a reliable signal, while the 1 mm medical foam backing and the internal metal foil guarantee a uniform distribution of current with minimal risk of burns.

As it is an adult/paediatric model, the same pair of electrodes serves patients over 10 kg: in Nihon Kohden Cardiolife devices, energy switching is performed using the physical ‘adult/paediatric’ switch on the defibrillator itself, which automatically reduces the shock in paediatric mode. The connector, with anti-shock safety, is inserted into the device socket following the anatomical diagrams on the packaging. It is a single-use product: it must be replaced after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Product type Disposable adult/paediatric multifunction electrodes, pre-connected (lead-out)
Compatibility Nihon Kohden Cardiolife AED 2100, AED 2150K and AED 2151K (also listed for AED 2152K according to the accessory manufacturer’s catalogue)
Population Adults and paediatric \u003E 10 kg (\u003E 12 months); contraindicated in children under 12 months / \u003C 10 kg
Functions Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h)
Conductive gel Low-impedance conductive adhesive gel
Backing material Medical foam (FOAM) 1 mm thick; conductive metal foil
Connector Anti-shock safety, accessible from outside the pouch (preconnected / lead-out)
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch (10 pairs per box)
Classification Medical device class IIb (EU Regulation 2017/745 – MDR)
Materials Latex and phthalate free; non-sterile
Shelf life Approx. 30 months from the date of manufacture; expiry date indicated on the packaging
Storage Dry place, +5 °C to +35 °C; operation 0 °C to +50 °C

Note: the active surface area and number of shocks fields for the adult/paediatric series (≈ 95 cm² active in adult and 50 shocks) correspond to typical values for the EuroDefiPads family; confirm with the technical department for this reference before tendering.

4. Equivalences and Cross-References

This product is a consumable compatible with Nihon Kohden defibrillators, not an original spare part from the equipment manufacturer: the connector and the monitoring system are proprietary to Nihon Kohden, so replacing the original pad with a compatible accessory must always be validated against the equipment’s technical data sheet and IFU. The original equipment manufacturer references that this electrode functionally covers are:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable adult/paediatric pad for Cardiolife AED (original equipment) P-740K Comparable by category (not interchangeable 1:1) Covers AED-2100K, 2150K, 2151K, 2152K, AED-3100 and TEC-5500/5600/7600/7700/8300 series (official IFU P-740K); 1.5 m cable. Factory original: connector, gel and labelling proprietary to Nihon Kohden
Nihon Kohden Preconnected disposable adult/paediatric electrode (original equipment) P-530K Comparable by category (not interchangeable 1:1) Original preconnected variant listed as an option for the AED-2100K and for the AED-3100; the electrodes remain connected to the AED in standby

There is no equivalence table validated by Nihon Kohden that authorises replacing the P-740K/P-530K references with third-party consumables: any comparison must be understood as comparable at category level, not interchangeable 1:1, and must be confirmed with the technical department before its use in tendering. The correspondence of this SKU (F7989UW) with the official Nihon Kohden construction is not published by the equipment manufacturer.

5. Selection tips and variants of interest

If your AED is a Nihon Kohden Cardiolife AED 2100, 2150K or 2151K and you serve the general population (adults and children), this pair of preconnected adult/paediatric electrodes is the most versatile option: a single pair of pads covers both populations and the paediatric energy is selected with the device switch, without the need for an additional set. For AED fleets or centres with high usage volume, manage stock rotation by expiry (≈ 30 months) and always replace the electrode after use or expiry.

As interesting variants in the catalogue, consider the electrode compatible with the same devices that also covers the 2152K model (SKU F7948UW), the version for the Mediana and Tecno-Gaz brands (F7986UW) if you have other AEDs, or the radiotransparent variant for imaging procedures if your centre performs interventional procedures. Consult the Cahnos technical department to confirm exact compatibility with your defibrillator model before placing large-volume orders or tenders.

Additional information

Compatibility

Nihon Kohden Cardiolife AED 2100, AED 2150K and AED 2151K (also listed for AED 2152K)

Population

Adults and paediatric patients > 10 kg (> 12 months); contraindicated in < 10 kg

Functions

Defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring (max. 24 h)

Backing material

1 mm medical foam (FOAM); conductive metal foil

Gel material

Low-impedance conductive adhesive gel

Connector

Anti-shock safety, accessible from outside the pouch (preconnected / lead-out)

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch (10 pairs per box)

Classification

Medical device class IIb (EU 2017/745 – MDR)

Use

Single-use, disposable

Shelf life

Approx. 30 months from manufacture; expiry date on packaging

Storage

Dry place, +5 °C to +35 °C; operation 0 °C to +50 °C

Exempt materials

Latex-free and phthalate-free

Manufacturer reference

Nihon Kohden P-740K / P-530K (original equipment parts, not 1:1 interchangeable)

Product type

Disposable adult/paediatric multifunction electrodes, pre-connected (lead-out)

Materials

Latex and phthalate free; non-sterile