Ensure your external defibrillator remains operational with this pair of original adult/paediatric electrodes for the CU Medical Systems CU-SPR device (device reference 35400-2) under reference 35405. These are the platform’s original pads (ORIGINAL PADS), supplied as 1 pair (2 units), disposable and single-use, suitable for resuscitating adult and paediatric patients in heart-safe locations, ambulances, health centres, companies and emergency care teams.
As a critical consumable, having the original replacement for the device ensures connector compatibility and correct energy management by the defibrillator, an essential aspect when treating both adults and children with the same unit.
2. Technical explanation of the equipment and procedure
Multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables ECG monitoring during care. This combined adult/paediatric pair allows the rescuer to cover patients of different ages with the same type of electrode, following in each case the energy configuration indicated in the CU-SPR operator’s manual.
The pads incorporate a low-impedance conductive adhesive gel that ensures homogeneous contact with the skin and efficient current transmission, minimising the risk of burns. Placement is carried out following the anatomical diagrams on the packaging and, after use or upon reaching the printed expiry date, they must be replaced with a new pair: they are single-use and must not be reused under any circumstances.
3. Technical specifications and product data
The verified product and registration details are set out below.
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35405 |
| Compatible equipment | CU Medical Systems – CU-SPR (device 35400-2) |
| Electrode type | Adult/paediatric, original, disposable – 1 pair (2 units) |
| Sales unit | Kit of 2 units (1 pair) |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C020501 |
| EAN | 8809435481215 |
Note: the electrodes correspond to the CU Medical Systems i-PAD CU-SPR platform and use the brand’s proprietary connector; always verify the exact device model and the packaging expiry date before clinical use.
4. Equivalences and Cross-References
This reference corresponds to the original replacement for the CU Medical Systems CU-SPR platform: the connector, the analysis algorithm and the device’s energy management are proprietary, so there is no validated equivalence table authorising replacement with third-party pads. Any comparison with electrodes from other manufacturers should be understood as comparable only by category (disposable adult/paediatric defibrillation electrode), not interchangeable 1:1. Within the Cahnos catalogue there are compatible electrodes of the same brand for other CU Medical platforms – such as F7958P/F7958PW (Paramedic CU-ER series) or F7959PL/F7959WPL (i-PAD NF1200/NF1201) – which use their own connectors and are not interchangeable with the CU-SPR. For use in tenders, consult the Cahnos technical department for compatibility verification by model and connector.
5. Selection tips and variants of interest
Confirm the device model: this pair of electrodes is the original replacement for the CU Medical Systems CU-SPR defibrillator (35400-2). Verify the model on the device plate before placing the order; AEDs from other CU Medical series (SP1, SP2, NFK200, NF1200/NF1201) use their own consumables.
Manage expiry and stock: always check the date printed on the packaging and do not use expired electrodes or those with an open or damaged sachet, as the gel may lose conductivity. As a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry (FIFO method).
Spare provision: replace the pair immediately after any real use so that the device remains always operational, and periodically check the battery status and the defibrillator’s self-test. For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model and serial number of the device.