Description
1. Commercial Introduction
The Rapid Triplex Norovirus / Rotavirus / Adenovirus Test (ref. INRA-635) is the comprehensive solution for screening the three most frequent viral causes of acute gastroenteritis at the point of care. With a single cassette and a single faecal sample, it provides, within minutes and by visual reading, a qualitative result for each of the three pathogens, speeding up clinical decision-making, optimising healthcare staff time and reducing the cost per determination compared with performing three individual tests.
Designed for professional use in hospital emergency departments, paediatric services, clinical laboratories, primary care, nursing homes and health centres, this test requires no additional instrumentation and offers clinical performance of up to 99.9% sensitivity for Norovirus (according to manufacturer’s data). The logistical presentation of 10 kits per box is designed to cover the average demand of a service with efficient storage.
2. Technical explanation of the procedure
The test is a single-step lateral flow chromatographic immunoassay (LFIA). Specific antibodies against Norovirus (genogroups I and II), Rotavirus and enteric Adenovirus antigens are immobilised on the cassette membrane. When the previously diluted faecal sample in the supplied buffer is deposited onto the sample well (S), the antigens present migrate by capillary action and react with the conjugates, generating independent coloured lines in the reading window for each analyte.
- Norovirus positive: coloured line in the Norovirus test zone next to the control line (C).
- Rotavirus positive: coloured line in the Rotavirus test zone next to the control line (C).
- Adenovirus positive: coloured line in the Adenovirus test zone next to the control line (C).
- Negative: only the control line (C) appears.
- Invalid: absence of control line; repeat with a new cassette.
The control line (C) validates in each assay the correct migration and the applied sample volume. Positive or equivocal results must be confirmed with reference laboratory methods (ELISA or RT-PCR) before making clinical decisions. It is a single-use device, exclusively for in vitro diagnostic use by qualified healthcare personnel; treat all samples as potentially infectious.
3. Technical Specifications
| Parameter | Specification |
| Test type | Rapid lateral flow immunochromatographic test, qualitative (triplex) |
| Analytes detected | Norovirus antigens (genogroups I and II), Rotavirus and Adenovirus |
| Sample type | Human faeces |
| Result type | Qualitative, visual reading (test T and control C lines) |
| Format | Single-use cassette for visual reading |
| Use | In vitro diagnostic (IVD), professional use, single-use |
| Reference Cahnos | INRA-635 |
| Manufacturer reference | Not verifiable in public sources; confirm with the manufacturer before use in tendering |
Packaging
| Item | Value |
| Kits per box | 10 kits per box |
| Boxes per carton | 40 boxes per carton (according to original data sheet, 900 kits per carton; confirm cubic capacity with technical department) |
| Carton dimensions | 51 × 43 × 41.5 cm |
| Weight per carton | 18.44 kg/carton |
Box contents
| Component | Quantity |
| Test cassettes (result reader) | 10 |
| Buffer | 1 |
| Droppers | 10 |
| Instruction manual | 1 |
Clinical data
| Analyte | Clinical sensitivity | Clinical specificity | Accuracy |
| Norovirus | 99.9 % | 98.1 % | 98.5 % |
| Rotavirus | 97.3 % | 97.1 % | 97.2 % |
| Adenovirus | 95.2 % | 97.7 % | 96.8 % |
Note: packaging, content and clinical performance data are reproduced verbatim from the product’s original technical data sheet.
4. Equivalences and Cross-References
Reference INRA-635 belongs to the category of rapid triplex tests for the detection of Norovirus, Rotavirus and Adenovirus antigens in human faeces by lateral flow immunochromatography. There is no official equivalence table validated by the manufacturer for this reference; the reference from another manufacturer indicated below is a functional category comparison verified against its manufacturer’s official catalogue, not interchangeable 1:1, and must be validated property by property (presentation, sample volume, reading time, genogroups covered and certification) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| R-Biopharm AG | RIDA®QUICK Rota/Adeno/Noro Combi | N1903 | Comparable by category (not interchangeable 1:1) | Same principle (lateral flow immunochromatography), same analytes (Norovirus genogroups I and II, Rotavirus and Adenovirus) and same matrix (human faeces). It differs in presentation: 25 tests per kit in individual cassettes versus the 10 kits per box of ref. INRA-635, and in the clinical performance data, which should be consulted in its IFU. Code confirmed in the official R-Biopharm catalogue. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. As homologous families in the category without a verified code in this review, the CerTest Biotec combo cards (ROTA+ADENO+NORO one step combo card) and the triplex panels from other manufacturers of gastrointestinal RDTs (e.g., combined Rota/Adeno/Noro panels from various Asian and European suppliers) are cited, whose commercial references must be checked against an official source before approval. Within the Cahnos catalogue, this test is complemented by the range of rapid tests for infectious diseases and multiplex respiratory panels to cover point-of-care differential diagnosis with a single supplier.
5. Selection tips and variants of interest
- Clinical indication: the triplex format is especially indicated in outbreaks of acute gastroenteritis, paediatrics and public health, where Norovirus, Rotavirus and Adenovirus are the predominant viral agents; a single sample allows all three to be ruled out or confirmed in a single assay.
- Sample type: use fresh faecal samples according to the package insert instructions and respect the reading times; do not interpret results outside the indicated window.
- Professional use: device for in vitro diagnostic professional use; positive results must be confirmed with reference techniques (ELISA, RT-PCR) according to clinical protocol.
- Care volume: the box of 10 kits is suitable for services with moderate demand; for campaigns or outbreaks, order the full carton (40 boxes) and consult our commercial team for special conditions.
- Storage: keep the cassettes in their sealed packaging, protected from humidity and direct sunlight, and respect the expiry date; do not freeze.
- Catalogue variants: for other enteric pathogens or expanded panels, consult the range of rapid tests for infectious diseases from Cahnos and request technical advice for approval at your centre.