MPOX virus (monkeypox) rapid antigen test in immunochromatographic cassette format, designed for the qualitative detection of the A29L antigen in human serum, plasma, whole blood, skin lesion swab and oropharyngeal samples. Detects the Clade Ib strain with a result in a maximum of 15 minutes and direct visual reading, without the need for additional instrumentation. Clinical data: relative sensitivity 93.75%, relative specificity 99.50% and accuracy 99.07%. Professional presentation of 25 units per box (40 boxes per carton, 1000 tests/carton), with sterile swabs, extraction tubes with buffer solution, workstation and instruction manual. For in vitro diagnostic use only.

International shipping. Import duties and taxes are payable by the recipient.

Reference
IMXG-402

You will also find it in

Description

1. Commercial Introduction

The MPOX Virus Rapid Antigen Test (SKU: IMXG-402) is the screening solution your centre needs to respond swiftly to monkeypox (MPOX) in primary care consultations, emergency departments, infectious disease units, travel medicine, and epidemiological surveillance campaigns. Thanks to its immunochromatographic cassette format, it delivers a reliable, easy-to-interpret result in a maximum of 15 minutes, without the need for laboratory equipment.

Designed for professional use in in vitro diagnostics, this test facilitates clinical decision-making at the point of care, optimises workflows and reduces reliance on molecular techniques for initial screening, making it a strategic ally for hospitals, private clinics and laboratories.

2. Technical explanation of the procedure

The test is a chromatographic lateral flow immunoassay intended for the qualitative detection of the A29L antigen of the monkeypox virus (MPXV) in human samples. On the cassette membrane, specific antibodies are immobilised that capture the viral antigen present in the sample; upon adding the buffer solution, the mixture migrates by capillary action and generates a coloured line in the test zone (T) when the result is positive. The control line (C) validates the correct functioning of the assay and the amount of sample applied.

The kit accepts multiple sample matrices: human serum, plasma, whole blood, skin lesion swab and oropharyngeal swab, and is validated for the detection of the Clade Ib strain, the most relevant variant in recent outbreaks. Positive or equivocal results must be confirmed by reference molecular techniques (RT-PCR), as recommended by the WHO laboratory guidelines for the diagnosis of MPOX.

3. Technical Specifications

Parameter Specification
Test type Qualitative chromatographic immunoassay (lateral flow), cassette format
Marker detected A29L antigen of the monkeypox virus (MPXV)
Strain detected Clade Ib
Sample type Human serum, plasma, whole blood, skin lesion exudate and oropharyngeal exudate
Reading time Maximum 15 minutes
Format Direct visual reading cassette
Use Professional, in vitro diagnostics
Storage 2 °C to 30 °C
Shelf life 24 months
Certification CE (marked for in vitro diagnostics)

Packaging:

Specification Value
Tests per box 25 units
Boxes per carton 40 boxes
Tests per carton 1,000 units
Carton dimensions 55 × 39.5 × 46 cm
Weight per carton 15.5 kg

Box contents:

Material Quantity
Test cassettes 25 units
Sterile swabs for oropharyngeal collection 25 units
Extraction tubes with buffer solution and dropper tip 25 units
Workstation 1 unit
Instruction manual 1 unit

Clinical data (validated against reference method):

Parameter Value
Relative sensitivity 93.75 %
Relative specificity 99.50 %
Accuracy 99.07 %

The CE declaration of conformity and the complete technical documentation are available on request through our commercial department.

4. Equivalences and Cross-References

The SKU IMXG-402 corresponds to the international reference IMXG-402 from Hangzhou Alltest Biotech (also distributed under the Spinreact brand), a manufacturer with CE certification for in vitro diagnostics and production compliant with ISO 13485. This reference shares technology and panel with other A29L antigen detection cassettes available on the European market, such as the Rapid Response™ Mpox Antigen Test by BTNX, the Biopanda cassette for MPOX, the test from Citest Diagnostics and Testsealabs-type cassettes, all based on lateral flow immunochromatography on serum, plasma, whole blood, skin swab or swab.

Within the Cahnos catalogue, this monovalent MPOX test is complemented by other rapid test references for infectious and tropical diseases from the same manufacturer and professional presentation in a box of 25 kits: IDZC-445 (arbovirus Dengue | Zika | Chikungunya IgG/IgM combo), IDEC-425 (dengue NS1 + IgG/IgM combo), IHBSG-402 (hepatitis B HBsAg) and ICHI-402 (chikungunya IgG/IgM). This family allows centralising the supply of serological and antigenic screening from a single supplier.

5. Selection tips and variants of interest

  • MPOX screening: choose reference IMXG-402 if your centre requires rapid detection of viral antigen in the active phase of infection, with special attention to the Clade Ib strain and sample collection by skin lesion or oropharyngeal swab.
  • Molecular confirmation: positive or equivocal results must be confirmed by MPXV-specific RT-PCR, especially in at-risk populations or outbreak settings, following the WHO and national surveillance network guidelines.
  • Scope of use: indicated for hospitals, emergency departments, infectious disease clinics, travel medicine units, primary care centres and epidemiological surveillance campaigns.
  • Throughput volume: the presentation of 25 tests per box (40 boxes per carton) is designed for centres with medium to high demand, optimising the cost per determination and storage.
  • Storage: keep the cassettes in their original packaging between 2 °C and 30 °C, protected from moisture and direct sunlight, and observe the indicated expiry date.

Additional information

Method

Rapid lateral flow chromatographic immunoassay in cassette format

Antigen detected

A29L antigen of the monkeypox virus (MPXV)

Strain detected

Clade Ib

Sample type

Human serum, plasma, whole blood, skin lesion exudate and oropharyngeal exudate

Reading time

Maximum 15 minutes

Reading

Direct visual (control line C and test line T)

Presentation

25 tests per box; 40 boxes per carton (1,000 tests/carton)

Box contents

25 cassettes, 25 sterile oropharyngeal swabs, 25 extraction tubes with buffer solution and dropper tip, 1 workstation, 1 instruction manual

Carton dimensions

55 × 39.5 × 46 cm

Carton weight

15.5 kg

Relative sensitivity

93.75 %

Relative specificity

99.50 %

Precision

99.07 %

Reference method

RT-PCR (confirmation according to WHO guidelines)

Storage

2 °C to 30 °C

Shelf life

24 months

Use

Professional, in vitro diagnostics

Certifications

CE / manufactured under ISO 13485

Manufacturer

Hangzhou Alltest Biotech / Spinreact

Reviews

There are no reviews yet.

Be the first to review “MPOX Virus Rapid Antigen Test (A29L, Clade Ib) – Immunochromatographic Cassette for Serum, Plasma, Whole Blood and Skin Swab | Professional Use (IMXG-402)”

Your email address will not be published. Required fields are marked *