Description
1. Rapid cardiac troponin T (cTnT) test for the diagnosis of myocardial infarction
The rapid cardiac troponin T (cTnT) test is the reference diagnostic solution for the early detection of damage to the cardiac muscle. When myocardial cells are injured, troponin T is released into the bloodstream and its concentration rises rapidly and significantly, making it an essential biomarker in the assessment of acute myocardial infarction (AMI) and acute coronary syndrome. This cassette-format test provides a reliable qualitative result in just 10 minutes, without the need for specialised equipment, making it especially valuable in hospital emergency departments, critical care units, medicalised ambulances, primary care consultations and clinical laboratories with a demand for immediate response. A professional-use product, easy to store and simple to handle, designed to expedite clinical decision-making in critical situations.
2. Principle of the test and procedure
The test is based on a chromatographic lateral flow immunoassay. Specific antibodies against human cardiac troponin T (cTnT) are immobilised on the reactive membrane of the cassette. When the sample (whole blood, serum or plasma) and the buffer are placed in the indicated well, the sample migrates by capillary action and, if it contains cTnT, reacts with the conjugates, generating a coloured line in the test region (T). The control line (C) always appears and indicates that the assay has been performed correctly, with the appropriate sample volume and correct membrane absorption. The reading is qualitative and visual: it is sufficient to observe the appearance of the coloured lines after 10 minutes, without the need for readers, advanced training or additional equipment. The analytical cut-off point of the assay is 0.5 ng/mL, allowing the detection of relevant elevations of troponin T at the point of care.
3. Technical specifications and data tables
| General characteristics |
| Format |
Lateral flow immunochromatography cassette |
| Analyte detected |
Human cardiac troponin T (cTnT), qualitative detection |
| Sample type |
Whole blood, serum or plasma |
| Reading time |
10 minutes |
| Cut-off point |
0.5 ng/mL |
| Result reading |
Qualitative and visual (control line C and test line T) |
| Storage |
2–30 °C, in a cool, dry place |
| Shelf life |
2 years |
| Certification |
CE marking – in vitro diagnostics (IVD) |
| Product name |
| Rapid test for cardiac troponin T |
| Box contents |
- 10 × Test cassettes
- 1 × Buffer
- 10 × Droppers
- 1 × Instruction manual
|
| Clinical data |
| Relative sensitivity |
98.6 % |
| Relative specificity |
99.5 % |
| Accuracy |
99.4 % |
| Packaging |
| Units |
10 kits per box |
| Quantity per carton |
100 boxes // 1000 kits |
| Dimensions |
63 × 37 × 30 cm |
| Weight |
9.65 kg |
| Detection |
| Time of appearance |
3–4 hours |
| Peak period |
24–28 hours |
| Return to normal |
10–14 days |
4. Equivalences and Cross-References
This kit corresponds to reference CTNT-402, a code used by the original manufacturer of the JusChek/Alltest range with CE marking, also available under manufacturer code 14602950300 (troponin T cassette, cut-off point 0.5 ng/mL) and under the equivalent reference 4001306 from the BIO-Troponin T line (cassette format for whole blood, serum or plasma). Within the Cahnos catalogue, this test is naturally complemented by reference CTI-402 (rapid test for cardiac troponin I), which shares the immunochromatographic methodology, cassette, presentation of 10 tests and reading times of 10 minutes. For a more complete cardiac assessment at the point of care, it is common to combine troponin determination with other markers such as myoglobin, CK-MB or NT-proBNP, available on request and with a formalised quotation. This family of cardiac markers allows the screening of myocardial damage to be completed with a single supplier, simplifying purchasing management and the approval of materials in healthcare centres.
5. Selection tips and variants of interest
For emergency departments, critical care units and prehospital medicine, this kit of 10 cassettes in box format is the most operational option: it allows maintaining an accessible stock of determinations for immediate response when a heart attack is suspected. If your centre also routinely assesses troponin I, we recommend completing the supply with reference CTI-402 from the same family. Remember that troponin T rises 3 to 4 hours after myocardial damage, reaches its peak between 24 and 28 hours and returns to normal in 10–14 days, so interpretation must consider the time elapsed since the episode. For high volumes, the carton format (100 boxes // 1000 kits) offers the best cost per determination and facilitates the centre’s logistical supply. Always store the product in a cool, dry place (2–30 °C), respect the 10-minute reading time and do not interpret the result beyond the interval indicated in the manual. For volume quotations, requests for technical documentation, safety data sheets or presentation variants on demand, contact our commercial department.
Reviews
There are no reviews yet.