Rapid Cardiac Troponin I (cTnI) Cassette Test – Lateral Flow Immunochromatographic Test for Whole Blood, Serum or Plasma | Ref. CTI-402

Price on request

Lateral flow immunochromatographic cassette test for the qualitative detection of cardiac troponin I (cTnI) in whole blood, serum or plasma, the reference biomarker in the diagnostics of acute myocardial infarction. Results in just 10 minutes with visual reading, cut-off of 0.5 ng/mL and relative sensitivity of 99.4%. The box includes 10 test cassettes, buffer, droppers and instruction manual. With CE marking for in vitro diagnostics, it is the ideal choice for emergency departments, critical care units, equipped ambulances and clinical laboratories that need an immediate and reliable response when myocardial damage is suspected. Reference CTI-402.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CTI-402

You will also find it in

Description

1. Commercial Introduction

The rapid cardiac troponin I (cTnI) test is the reference diagnostic solution for the early detection of damage to the cardiac muscle and acute myocardial infarction (AMI). When myocardial cells are injured, troponin I is released into the bloodstream and its concentration rises rapidly and significantly, making it the most specific and sensitive biomarker in the assessment of acute coronary syndrome. This cassette-format test provides a reliable qualitative result in just 10 minutes, without the need for specialised equipment, which makes it especially valuable in hospital emergency departments, critical care units, medicalised ambulances, primary care practices and clinical laboratories with a demand for immediate response. A professional-use product, easy to store and simple to handle, designed to expedite clinical decision-making in critical situations. Reference CTI-402.

2. Principle of the test and procedure

The test is based on a lateral flow chromatographic immunoassay. Specific antibodies against human cardiac troponin I (cTnI) are immobilised on the reactive membrane of the cassette. When the sample (whole blood, serum or plasma) and, if applicable, the buffer are placed in the indicated well, the sample migrates by capillary action and, if it contains cTnI, reacts with the conjugates, generating a coloured line in the test region (T). The control line (C) always appears and indicates that the assay has been performed correctly, with the appropriate sample volume and correct membrane absorption. The reading is qualitative and visual: it is sufficient to observe the appearance of the coloured lines after 10 minutes, without the need for readers, advanced training or additional equipment. The analytical cut-off point of the assay is 0.5 ng/mL, which allows detection of relevant elevations of troponin I at the point of care. The procedure is simple: a rapid chromatographic method that requires only a few steps, without complex pipetting or prior preparation of reagents.

3. Technical Specifications

The general characteristics of the device, the contents of the box, clinical data, packaging and the detection kinetics of the marker are detailed below.

General characteristics
Reference CTI-402
Format Lateral flow immunochromatography cassette
Analyte detected Human cardiac troponin I (cTnI), qualitative detection
Sample type Whole blood (venous or capillary), serum or plasma
Reading time 10 minutes (do not interpret after 20 minutes)
Cut-off point 0.5 ng/mL
Result reading Qualitative and visual (control line C and test line T)
Storage 2–30 °C, in a cool, dry place
Shelf life 2 years
Certification CE marking – in vitro diagnostics (IVD)
Product name
Rapid test for cardiac Troponin I
Box contents
  • 10 × Test cassettes
  • 1 × Buffer
  • 10 × Droppers
  • 1 × Instruction manual
Clinical data
Relative sensitivity 99.4 %
Relative specificity 99.0 %
Accuracy 99.1 %
Packaging
Units 10 kits per box
Quantity per carton 90 boxes // 900 kits
Dimensions 51 × 43 × 41.5 cm
Weight 10.1 kg
Detection
Time of appearance 3–4 hours
Peak period 11–24 hours
Return to normal 7–10 days

4. Equivalences and Cross-References

This kit corresponds to reference CTI-402, a code used by the original manufacturer of the JusChek/Alltest range (Hangzhou Alltest Biotech) with CE marking, also available under reference CTI-402F from Spinreact’s rapid test line (same cardiac troponin I cassette for whole blood, serum or plasma) and also manufactured by Citest Diagnostics Inc. under the same catalogue code CTI-402. Within the Cahnos catalogue, this test is naturally complemented by reference CTNT-402 (rapid test for cardiac Troponin T), which shares the immunochromatographic methodology, cassette, presentation of 10 tests and reading times of 10 minutes. For a more complete cardiac assessment at the point of care, it is common to combine troponin determination with other markers such as myoglobin, CK-MB or NT-proBNP, available on request and with a formalised quotation. This family of cardiac markers allows the screening of myocardial damage to be completed with a single supplier, simplifying purchasing management and the approval of materials in healthcare centres.

5. Selection tips and variants of interest

For emergency departments, critical care units and prehospital medicine, this kit of 10 cassettes in box format is the most practical option: it allows you to maintain an accessible stock of tests for immediate response when a heart attack is suspected. If your centre routinely assesses troponin T, we recommend completing the supply with reference CTNT-402 from the same family. Remember that troponin I rises 3 to 4 hours after myocardial damage, peaks between 11 and 24 hours and returns to normal in 7–10 days (a longer detection window than CK-MB), so interpretation must consider the time elapsed since the episode. For high volumes, the carton format (90 boxes // 900 kits) offers the best cost per test and facilitates the centre’s logistical supply. Always store the product in a cool, dry place (2–30 °C), respect the 10-minute reading time and do not interpret the result beyond the 20 minutes indicated in the manual. For volume quotations, requests for technical documentation, safety data sheets or custom presentation variants, please contact our sales department.

Additional information

Reference

CTI-402

Product type

Rapid immunochromatographic test in cassette

Technology

Lateral flow chromatographic immunoassay (immunochromatography)

Manufacturer

Hangzhou Alltest Biotech (JusChek/Alltest range)

Analyte detected

Human cardiac troponin I (cTnI), qualitative detection

Sample type

Whole blood (venous or capillary), serum or plasma

Cut-off point

0.5 ng/mL

Reading time

10 minutes (do not interpret after 20 minutes)

Relative sensitivity

99.4 %

Relative specificity

99.0 %

Precision

99.1 %

Presentation

Box with 10 cassettes, buffer, droppers and instruction manual

Packaging

10 kits per box; 90 boxes per carton (900 kits)

Carton dimensions

51 × 43 × 41.5 cm

Weight

10.1 kg

Storage

2–30 °C, in a cool, dry place

Shelf life

2 years

Certifications

CE marking – in vitro diagnostics (IVD)

Time of appearance

3–4 hours

Peak period

11–24 hours

Return to normal

7–10 days