Description
1. Commercial Introduction
The SARS-CoV-2 Rapid Antigen Test (self test) is the practical, simple and reliable self-screening solution for the qualitative detection of active COVID-19 infection. Designed for self-diagnosis, it provides a clear result in just 15 minutes from a nasal swab sample, without the need for laboratory equipment or specialised personnel. Its high performance (diagnostic sensitivity of 100% and diagnostic specificity of 99.5%) makes it the ideal tool for community pharmacies, pharmacy offices, homes, offices and work environments that need an immediate and reliable response at the point of care or at home.
2. Technical explanation of the procedure
The device is a rapid membrane chromatographic immunoassay (lateral flow immunochromatography) for the qualitative detection of SARS-CoV-2 nucleocapsid protein antigens in nasal swab samples. Specific antibodies against the viral antigen are immobilised on the reactive membrane of the cassette: when the extracted sample is added, the mixture migrates by capillary action and the appearance of a coloured line in the test region (T) indicates the presence of the virus, while the control line (C) always validates the correct performance of the assay.
Summary procedure: (1) wash your hands and open the sealed sachet; (2) take the sample with the included sterile nasal swab; (3) insert the swab into the extraction buffer and mix properly; (4) add the extracted sample to the well (S) of the cassette; (5) read the result after 15 minutes and interpret it visually; the control line must always appear to validate the test.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 24584 |
| SKU Cahnos | GM24584 |
| Sales unit | 1 pc (box of 1 test) |
| Device type | IVD – Self Test |
| CND | W0105099099 |
| EAN | 6970277517539 |
Test characteristics
| Parameter | Specification |
|---|---|
| Detection method | Rapid membrane chromatographic immunoassay (lateral flow immunochromatography) |
| Analyte detected | SARS-CoV-2 nucleocapsid protein antigens (COVID-19) |
| Sample type | Nasal swab |
| Format | Individual test cassette (single-use) |
| Time to result | 15 minutes |
| Intended use | Self-diagnosis (self test) |
| Storage | 2-30 °C |
| Shelf life | 24 months from the date of manufacture (average stock shelf life Gima: 4 to 16 months) |
| Diagnostic sensitivity | 100% (95% CI: 98.9% – 100%) |
| Diagnostic specificity | 99.5% (95% CI: 98.6% – 99.9%) |
Kit contents (box of 1 test)
| Materials included | Quantity |
|---|---|
| Test cassette | 1 |
| Sterile nasal swab | 1 |
| Extraction buffer | 1 |
| Package insert / instructions for use | 1 |
| Biosecurity bag | 1 |
| Box and multilingual manual (GB, FR, IT, ES, PT, DE, NL, DK, SE, FI, NO, GR) | 1 |
4. Equivalences and Cross-References
| Manufacturer | Reference | Presentation | Scope of use |
|---|---|---|---|
| Catalogue Cahnos | 24584 | Box of 1 test, nasal swab | Self test (self-diagnosis) |
| Catalogue Cahnos | 24586 | Box of 20 tests, nasopharyngeal swab | Professional use |
| Catalogue Cahnos | 24588 | Box of 1 test, oral fluid (saliva) | Self test (self-diagnosis) |
| Catalogue Cahnos | 24590 | Box of 20 tests, oral fluid (saliva) | Professional use |
Reference 24584 belongs to the SARS-CoV-2 antigen test family and shares technology, analytical basis (nucleocapsid protein) and CND code with the professional version 24586 (same brand, nasopharyngeal sample, box of 20 tests). Within the Cahnos catalogue, this test is comparable by category (not interchangeable 1:1) with other antigenic RDTs for COVID-19 detection, such as L031-11815 (Flowflex™, professional-use cassette with nasal and nasopharyngeal swab) and 181001 (Operon SIMPLE/STICK, professional use in healthcare settings). There is no manufacturer-validated equivalence table for this reference; before any substitution, the device format, authorised sample type, intended use (self-diagnosis vs professional) and performance data of each technical data sheet must be verified.
5. Selection tips and variants of interest
Home self-diagnosis: this self-test presentation with nasal swab and 15-minute reading is indicated for home screening, offices, pharmacies and work environments; it is a single-use device that is very easy to handle. For healthcare centres or high-throughput screening, consider the professional variant GM24586 (box of 20 tests, nasopharyngeal swab) or, if a non-invasive sample without swabbing is preferred, the saliva family GM24588 (self test) and GM24590 (professional use).
Confirmation of results: as with any rapid antigen test, positive, negative or doubtful results must be confirmed by molecular techniques (PCR) according to current health recommendations, especially in at-risk patients or when the viral load may be below the detection threshold.
Storage: keep the cassette in its sealed packaging between 2 °C and 30 °C, protected from humidity and direct sunlight, and always respect the indicated expiry date. For large orders you can request a quote: contact our Cahnos sales team for B2B conditions and volume orders.





Reviews
There are no reviews yet.