We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Flowflex™ SARS-CoV-2 (COVID-19) Rapid Antigen Test | Professional TROD in Cassette with Nasal and Nasopharyngeal Swab | Box of 25 Kits (L031-11815)

Price on request

The Flowflex™ SARS-CoV-2 rapid antigen test from ACON Biotech is a rapid diagnostic test (TROD) for professional use only, detecting active COVID-19 infection in about 15 minutes via lateral flow immunochromatography from a nasal or nasopharyngeal swab sample. With a clinical sensitivity of 96.18% and a specificity of 99.72% compared to PCR, it is the ideal screening solution for hospitals, primary care centres, pharmacies, private clinics and healthcare residences. It is supplied in a box of 25 individual kits with a double test cassette, sterile nasal swabs, extraction tubes and droppers, with no need for additional equipment. Storage at room temperature (2–30 °C).

International shipping. Import duties and taxes are payable by the recipient.

Reference
L031-11815

Description

1. Introduction

The Flowflex™ SARS-CoV-2 rapid antigen test is an in vitro diagnostic device (TROD) for professional use only that enables qualitative detection of COVID-19 infection in patients, both symptomatic within the first 7 days of symptom onset and asymptomatic. Manufactured by ACON Biotech (Hangzhou) Co., Ltd. and distributed by Cahnos in a professional format of 25 kits per box, it is the benchmark screening tool in hospitals, emergency departments, primary care, pharmacies, private practices and healthcare residences, thanks to its speed, reliability and ease of use at the point of care.

2. Technical explanation of the procedure

The device uses a lateral flow chromatographic immunoassay for the qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in nasal or nasopharyngeal swab samples. Specific antibodies immobilised on the cassette membrane capture viral antigens present in the sample; when the extracted sample is added to the well, the mixture migrates by capillary action and the appearance of a coloured line in the test zone (T) indicates the presence of the virus, while the control line (C) validates correct assay function.

Summary procedure:

  1. Allow the kit to reach room temperature and wash your hands.
  2. Collect the sample with the sterile nasal swab (or nasopharyngeal per protocol).
  3. Insert the swab into the blood collection tube with the buffer and mix.
  4. Add the extracted sample to the indicated well of the cassette (S).
  5. Wait 15 minutes and read the result; the control line must always appear to validate the test.

3. Technical Specifications

General characteristics
Detection method Lateral flow chromatographic immunoassay (qualitative detection of antigens)
Pathogen detected SARS-CoV-2 (COVID-19) – nucleocapsid protein antigen
Sample type Nasal and nasopharyngeal swab
Reading time 15 minutes
Reference method PCR
Format Test cassette / individual kit
Use Professional only (TROD – rapid test for healthcare use)
Manufacturer ACON Biotech (Hangzhou) Co., Ltd. – Flowflex™ brand
Storage 2 °C – 30 °C (room temperature)
Shelf life 24 months

Packaging

Packaging
Units 25 kits per box
Quantity per carton 32 boxes per carton // 800 kits per carton
Dimensions 530 × 445 × 410 mm
Weight 13 kg/carton

Box contents

Box contents
  • 25 × Double test cassettes
  • 25 × Sterile nasal swabs
  • 25 × Blood collection tubes
  • 25 × Droppers
  • 1 × Instruction manual

Clinical data

Clinical data
Clinical sensitivity 96.18 %
Clinical specificity 99.72 %

Clinical data published by the manufacturer (vs. PCR)

Parameter Value
Sensitivity (nasal swab) 97.1% (95% CI: 93.1% – 98.9%)
Sensitivity (nasopharyngeal swab) 97.6% (95% CI: 92.8% – 99.5%)
Specificity (nasal swab) 99.5% (95% CI: 98.2% – 99.9%)
Specificity (nasopharyngeal swab) 99.4% (95% CI: 96.5% – 99.9%)
Overall accuracy 98.8 %

4. Equivalences and Cross-References

Reference L031-11815 belongs to the Flowflex™ family from manufacturer ACON Biotech and is directly equivalent to other presentations of the same product with different packaging:

  • L031-11825 – Flowflex™ SARS-CoV-2 (cassette, nasal/nasopharyngeal swab, 25 tests per kit).
  • L031-11845 – Flowflex™ SARS-CoV-2 (cassette, nasal swab, 1 test per kit, 20 kits per box).
  • L031-118C5 – Flowflex™ SARS-CoV-2 (cassette, nasal swab, 5 tests per kit).

Within the Cahnos respiratory rapid test catalogue, equivalent or complementary references from other manufacturers include: 181001 (Operon COVID-19 antigen test, colloidal method, box of 20 units), IRT-545 / IRT-545-1 (multiplex panels adding flu A/B, RSV and adenovirus), COIF-522 (SEJOY Covid | flu A & B multiplex antigen test, box of 25 units), IU-COVTESG-8 (Safecare combined Covid-19 and flu A/B test), ICIC-525 (Covid-19 and Influenza A+B rapid antigen test) and MF-71-1 (multiplex self-test reading in 12 minutes).

5. Selection tips and variants of interest

  • Professional COVID-19 screening: this monovalent test is the most cost-effective and simple option when only SARS-CoV-2 coverage is needed at the point of care.
  • Detection window: its use is recommended in symptomatic patients within the first 7 days of symptom onset, as well as in asymptomatic individuals and close contacts.
  • High‑volume centres: with 800 kits per carton, the 25‑unit presentation optimises cost per test, storage and logistics in screening campaigns and peak season.
  • Seasonal differential diagnosis: if your facility also needs to distinguish flu A/B, RSV or adenovirus in a single sample, consider the multiplex panels IRT-545/IRT-545-1, COIF-522 or ICIC-525.
  • Storage and shelf life: store at 2–30 °C in the sealed pouch; shelf life of 24 months. Always check the kit condition before use.
  • Clinical recommendation: confirm positive results by PCR before making therapeutic decisions, especially in at‑risk patients.

Additional information

Detection method

Lateral flow chromatographic immunoassay (immunochromatography)

Pathogen detected

SARS-CoV-2 (COVID-19)

Diagnostic target

SARS-CoV-2 nucleocapsid protein antigen

Sample type

Nasal and nasopharyngeal swab

Reading time

15 minutes

Reference method

PCR

Clinical sensitivity

96.18% (97.1% according to manufacturer published data)

Clinical specificity

99.72% (99.5% according to manufacturer published data)

Presentation

25 kits per box

Box contents

25 double cassettes, 25 sterile nasal swabs, 25 blood collection tubes, 25 droppers and 1 instructions for use manual

Carton packaging

32 boxes per carton // 800 kits per carton

Carton dimensions

530 × 445 × 410 mm

Carton weight

13 kg

Storage

2 °C – 30 °C

Shelf life

24 months

Certifications

CE-IVD · TROD for professional use

Format

Test cassette (individual kit)

Use

Professional in vitro diagnostics (rapid test for healthcare use)

Reviews

There are no reviews yet.

Be the first to review “Flowflex™ SARS-CoV-2 (COVID-19) Rapid Antigen Test | Professional TROD in Cassette with Nasal and Nasopharyngeal Swab | Box of 25 Kits (L031-11815)”

Your email address will not be published. Required fields are marked *