Description
1. Introduction
The Procalcitonin (PCT) Test in cassette is the reference diagnostic solution for the rapid detection and monitoring of infectious and septic processes at the point of care. Specifically designed for the fluorescence immunoassay analyser Ref. 24600, it offers immediate, reliable and reproducible results without the need for large equipment or laboratory infrastructure. Perfect for emergency departments, intensive care units, clinical laboratories and primary care centres that need a rapid response to suspected sepsis, bacterial infection or to guide antibiotic therapy.
2. Technical explanation of the test
Procalcitonin (PCT) is a biomarker that rises early and significantly in response to severe bacterial infections and sepsis, making it a key clinical tool for the differential diagnosis between bacterial and viral aetiology, as well as for monitoring patient progress and treatment efficacy. This cassette is ready to use: the sample is placed on the cassette with the included 75 µl precision dropper and inserted into the analyser Ref. 24600, which performs the reading by fluorescence immunoassay and displays the result immediately and objectively, eliminating the subjectivity of visual interpretation. The kit includes all the elements necessary for the determination: identification card (batch identification and calibration), reaction cassette and buffer solution. This reference is part of a family of up to 12 cassette tests in the catalogue compatible with the same analyser, allowing the diagnostic panel to be centralised in a single device.
3. Technical specifications and product data
| Parameter | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 24606 (SKU Cahnos: GM24606) |
| Parameter detected | Procalcitonin (PCT) – inflammatory marker |
| Technology | Fluorescence immunoassay (cassette test) |
| Compatibility | Immunofluorescence analyser Ref. 24600 |
| Results | Immediate, with objective reading on the analyser |
| Sales unit | Box of 10 units (box of 10 pcs) |
| Device type | IVD – Professional use (IVD – Professional Use) |
| CND | W0102069013 |
| EAN | 6936983165051 |
Kit contents
| Item | Description |
|---|---|
| Identification card | ID Card (batch identification and calibration) |
| Test cassette | Ready to use |
| Buffer solution | Buffer |
| Precision dropper | 1 dropper of 75 µl |
Range of cassette tests for the analyser Ref. 24600
| Parameter | Reference | Category |
|---|---|---|
| CRP | 24605 | Inflammatory markers |
| Procalcitonin (PCT) | 24606 | Inflammatory markers |
| D-dimer | 24608 | Coagulation |
| Troponin I (cTnI) | 24610 | Cardiac |
| Renal insufficiency (N-GAL) | 24612 | Nephrology |
| Glycated haemoglobin (HbA1c) | 24614 | Diabetes |
| Influenza A/B | 24618 | Infectious diseases |
| Strep A | 24619 | Infectious diseases |
| VRS/RSV | 24620 | Infectious diseases |
| COVID-19 (antigen) | 24622 | Infectious diseases |
| COVID-19 (antibodies) | 24623 | Infectious diseases |
| Vitamin D | 24625 | Vitamins |
4. Equivalences and Cross-References
The cassette system for the 24600 analyser is a closed system: no direct equivalences with procalcitonin cassettes from other manufacturers have been verified in reliable sources. To guarantee the reliability of the results, this test (reference 24606, SKU Cahnos GM24606) must be used exclusively with the analyser Ref. 24600 and is not interchangeable with rapid lateral flow tests with visual reading or with reagents from other platforms without previously validating compatibility. The same family of cassettes for this analyser, available in the Cahnos catalogue, includes: CRP test (GM24605), procalcitonin test (GM24606), D-Dimer test (GM24608), Troponin I cTnI test (GM24610), renal failure test (GM24612), glycosylated haemoglobin test (GM24614), Influenza A/B test (GM24618), Strep A test (GM24619), VRS/RSV test (GM24620), COVID-19 test in its antigen (GM24622) and antibody (GM24623) variants, and vitamin D test (GM24625). Consult our technical-commercial team to confirm availability and replenishment references.
5. Selection tips and variants of interest
Verify that you have the analyser Ref. 24600 for the use of this cassette, as it is specifically designed for this immunofluorescence platform. The presentation in a box of 10 units is the manufacturer’s standard sales unit and allows continuous replenishment planning of all parameters of your diagnostic panel from a single platform. This test is especially recommended in emergency and intensive care settings, and can be combined with other markers in the range such as the CRP test (GM24605) to complete the assessment of the patient with suspected infection or the D-Dimer test (GM24608) in processes involving coagulation disorders. Request a quote from our technical-commercial team to plan your consumables orders and ensure the supply of the different tests in the range. For any questions about compatibility or selection of variants, our team is at your disposal.