We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Procalcitonin (PCT) Test in Cassette for Immunofluorescence Analyser Ref. 24600 (Ref. 24606) – Box of 10 units

50,35 €

Procalcitonin (PCT) test in cassette ready to use, specifically designed for the fluorescence immunoassay analyser Ref. 24600. Reference biomarker in the diagnostic orientation of sepsis and bacterial infections, with immediate results and objective reading at the point of care. Presentation in a box of 10 determinations; the kit includes ID card, cassette, buffer solution and 1 precision dropper of 75 µl. In vitro diagnostic (IVD) for professional use. Ideal for completing your clinical panel of up to 12 parameters on a single platform.

Sales unit: caja de 10
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM24606

Description

1. Introduction

The Procalcitonin (PCT) Test in cassette is the reference diagnostic solution for the rapid detection and monitoring of infectious and septic processes at the point of care. Specifically designed for the fluorescence immunoassay analyser Ref. 24600, it offers immediate, reliable and reproducible results without the need for large equipment or laboratory infrastructure. Perfect for emergency departments, intensive care units, clinical laboratories and primary care centres that need a rapid response to suspected sepsis, bacterial infection or to guide antibiotic therapy.

2. Technical explanation of the test

Procalcitonin (PCT) is a biomarker that rises early and significantly in response to severe bacterial infections and sepsis, making it a key clinical tool for the differential diagnosis between bacterial and viral aetiology, as well as for monitoring patient progress and treatment efficacy. This cassette is ready to use: the sample is placed on the cassette with the included 75 µl precision dropper and inserted into the analyser Ref. 24600, which performs the reading by fluorescence immunoassay and displays the result immediately and objectively, eliminating the subjectivity of visual interpretation. The kit includes all the elements necessary for the determination: identification card (batch identification and calibration), reaction cassette and buffer solution. This reference is part of a family of up to 12 cassette tests in the catalogue compatible with the same analyser, allowing the diagnostic panel to be centralised in a single device.

3. Technical specifications and product data

Parameter Value
Manufacturer GIMA
Manufacturer reference 24606 (SKU Cahnos: GM24606)
Parameter detected Procalcitonin (PCT) – inflammatory marker
Technology Fluorescence immunoassay (cassette test)
Compatibility Immunofluorescence analyser Ref. 24600
Results Immediate, with objective reading on the analyser
Sales unit Box of 10 units (box of 10 pcs)
Device type IVD – Professional use (IVD – Professional Use)
CND W0102069013
EAN 6936983165051

Kit contents

Item Description
Identification card ID Card (batch identification and calibration)
Test cassette Ready to use
Buffer solution Buffer
Precision dropper 1 dropper of 75 µl

Range of cassette tests for the analyser Ref. 24600

Parameter Reference Category
CRP 24605 Inflammatory markers
Procalcitonin (PCT) 24606 Inflammatory markers
D-dimer 24608 Coagulation
Troponin I (cTnI) 24610 Cardiac
Renal insufficiency (N-GAL) 24612 Nephrology
Glycated haemoglobin (HbA1c) 24614 Diabetes
Influenza A/B 24618 Infectious diseases
Strep A 24619 Infectious diseases
VRS/RSV 24620 Infectious diseases
COVID-19 (antigen) 24622 Infectious diseases
COVID-19 (antibodies) 24623 Infectious diseases
Vitamin D 24625 Vitamins

4. Equivalences and Cross-References

The cassette system for the 24600 analyser is a closed system: no direct equivalences with procalcitonin cassettes from other manufacturers have been verified in reliable sources. To guarantee the reliability of the results, this test (reference 24606, SKU Cahnos GM24606) must be used exclusively with the analyser Ref. 24600 and is not interchangeable with rapid lateral flow tests with visual reading or with reagents from other platforms without previously validating compatibility. The same family of cassettes for this analyser, available in the Cahnos catalogue, includes: CRP test (GM24605), procalcitonin test (GM24606), D-Dimer test (GM24608), Troponin I cTnI test (GM24610), renal failure test (GM24612), glycosylated haemoglobin test (GM24614), Influenza A/B test (GM24618), Strep A test (GM24619), VRS/RSV test (GM24620), COVID-19 test in its antigen (GM24622) and antibody (GM24623) variants, and vitamin D test (GM24625). Consult our technical-commercial team to confirm availability and replenishment references.

5. Selection tips and variants of interest

Verify that you have the analyser Ref. 24600 for the use of this cassette, as it is specifically designed for this immunofluorescence platform. The presentation in a box of 10 units is the manufacturer’s standard sales unit and allows continuous replenishment planning of all parameters of your diagnostic panel from a single platform. This test is especially recommended in emergency and intensive care settings, and can be combined with other markers in the range such as the CRP test (GM24605) to complete the assessment of the patient with suspected infection or the D-Dimer test (GM24608) in processes involving coagulation disorders. Request a quote from our technical-commercial team to plan your consumables orders and ensure the supply of the different tests in the range. For any questions about compatibility or selection of variants, our team is at your disposal.

Additional information

Manufacturer reference

24606

Sales unit

Box of 10 units (box of 10 pcs)

Device type

IVD – Professional Use

CND code

W0102069013

EAN

6936983165051

Analyte detected

Procalcitonin (PCT)

Technology

Fluorescence immunoassay (cassette test)

Compatibility

Immunofluorescence analyser ref. 24600

Results

Immediate, with objective reading on the analyser

Sample

Application with precision dropper of 75 µl

Contents

ID card, cassette, buffer solution and 1 dropper of 75 µl

Presentation

Box of 10 ready-to-use determinations

Presentacion

Box of 10

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Procalcitonin (PCT) Test in Cassette for Immunofluorescence Analyser Ref. 24600 (Ref. 24606) – Box of 10 units”

Your email address will not be published. Required fields are marked *