Description
1. Commercial Introduction
The haemoglobin microcuvettes for Hemo Control are the official consumable for the Hemo Control analyzer (reference 23994), designed for the rapid, simple and accurate determination of haemoglobin (Hb) and haematocrit (Hct) in whole blood. Supplied in a convenient box of 50 single-use units, they ensure traceability and reliability of readings in medical practices, health centres, laboratories and care services that need a point-of-care result, without relying on large laboratory infrastructures.
2. Technical explanation of the procedure
The Hemo Control analyzer uses a photometric method with azide methaemoglobin reaction to quantify haemoglobin and haematocrit from venous, arterial or capillary whole blood. The procedure is simple and is carried out in three steps: a microsample of 8 µl is collected, the microcuvette is inserted into the analyzer and the reading is obtained on the touchscreen in 25-60 seconds. The device includes automatic self-test and does not require manual calibration, yields results in the range of 0 to 25.6 g/dL (0-15.9 mmol/L) with an accuracy of less than 2% and is calibrated according to the NCCLS standard.
3. Technical specifications and product data
The product technical data sheet details are given below, preserving the manufacturer’s original information:
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 23995 (SKU Cahnos: GM23995) |
| Compatible product | Haemoglobin microcuvettes for Hemo Control, code 23994 |
| Sales unit | Box of 50 units (box of 50 pcs) |
| Device type | IVD – Professional use (IVD – Professional Use) |
| CND | W0103010201 |
| EAN | 8023279239959 |
Features of the compatible system (Hemo Control, ref. 23994)
| Parameter | Haemoglobin (Hb) and haematocrit (Hct) in whole blood |
|---|---|
| Measurement method | Photometric, azide methaemoglobin |
| Measurement range | 0 – 25.6 g/dL; 0 – 15.9 mmol/L |
| Sample volume | 8 µl |
| Sample type | Venous, arterial or capillary blood |
| Accuracy | <2% |
| Linearity | 0 – 20 g/dL ±0.3 g/dL; >20 g/dL ±0.7 g/dL |
| Time to result | 25 – 60 seconds |
| Calibration | NCCLS standard |
4. Equivalences and Cross-References
This consumable is part of the closed Hemo Control system: the microcuvettes (ref. 23995) must be used exclusively with the Hemo Control analyzer (ref. 23994, SKU Cahnos GM23994) to ensure the reliability of results. No 1:1 equivalents with microcuvettes from other manufacturers have been documented in reliable sources, as the physical and optical compatibility is specific to this platform. Nor are they interchangeable with other haemoglobin systems in the catalogue, such as the GIMACARE monitor strips (ref. 24137) or the MISSION® Hb system (ref. 24022), which use different technologies and sample formats (reflectance strips).
5. Selection tips and variants of interest
If you already have the Hemo Control analyzer (ref. 23994), this box of 50 haemoglobin microcuvettes is the recommended replacement to maintain your routine of Hb/Hct determinations. The box of 50 units is suitable for practices and centres with medium demand; for sustained volumes or institutional contracts, we recommend planning supply with our technical-commercial team. Always check that the batch corresponds to reference 23995 and keep the microcuvettes in their original packaging, protected from moisture and light, following the manufacturer’s instructions for use and expiry date.





Reviews