We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Operon SIMPLE/STICK Ag SARS-CoV-2 COVID-19 Rapid Antigen Test – Qualitative Detection of Nucleocapsid Antigen in Nasal Swab, Lateral Flow Immunochromatography (CE-IVD), Professional Use in Healthcare Settings, Box of 20 Units

Original price was: 94,00 €.Current price is: 90,00 €.

Operon SIMPLE/STICK Ag SARS-CoV-2 COVID-19 rapid antigen test, manufactured in Spain by OPERON S.A., for the qualitative in vitro detection of the SARS-CoV-2 nucleocapsid antigen in nasal swab (NS) samples. Lateral flow immunochromatographic method with colloidal gold, result in approximately 10 minutes, visual or automatic reading with OPERON LF Reader and agreement with RT-PCR of 96.4% sensitivity and 100% specificity. By detecting the N protein (and not the mutation points of the S protein), it maintains the ability to detect circulating variants of concern. Professional use by clinical laboratories and healthcare personnel in healthcare settings, indicated within the first 5 days from symptom onset; not suitable for self-testing. Presentation in a box of 20 units, nasal swabs included and CE-IVD marking (Directive 98/79/EC).

International shipping. Import duties and taxes are payable by the recipient.

Reference
181001

Description

1. Commercial Introduction

The Rapid COVID-19 Antigen Test Operon SIMPLE/STICK Ag SARS-CoV-2 is a single-step in vitro diagnostic device (TROD) designed for the qualitative detection of the SARS-CoV-2 nucleocapsid antigen in nasal swab samples. Manufactured in Spain by OPERON S.A., it provides a fast and reliable screening response at the point of care: clinical laboratories, hospitals, emergency departments, primary care, private practices and healthcare residences. Its simple/stick format, ready to use and requiring no additional equipment, makes it the ideal tool for screening patients with suspected COVID-19 during the first days of symptoms, with results in approximately 10 minutes and with the guarantee of the CE-IVD marking.

2. Technical explanation of the procedure

The device uses a lateral flow chromatographic immunoassay (colloidal method with gold nanoparticles) for the qualitative detection of the nucleocapsid protein (N protein) antigen of SARS-CoV-2. By targeting the nucleocapsid and not the mutation points of the spike protein (S), the test maintains its diagnostic capability against circulating variants of concern. The sample is collected with the included nasal swab, introduced into the extraction buffer and the mixture migrates by capillary action along the test strip: the appearance of a coloured line in the test zone (T) indicates the presence of the virus, while the control line (C) validates the correct functioning of the assay.

Summary procedure:

  • Allow the kit to reach room temperature and wash your hands.
  • Collect the sample with the included nasal swab, rotating it gently in the nostril.
  • Insert the swab into the container with the extraction buffer and mix properly.
  • Add the extracted sample to the indicated well of the device.
  • Wait the indicated reading time (approximately 10 minutes) and read the result; the control line must always appear to validate the test.

Indication for use (manufacturer’s data sheet): «For the qualitative in vitro detection of the SARS-CoV-2 nucleocapsid antigen in nasal swab (NS) samples from people with suspected COVID-19 within the first 5 days after symptom onset. This test is used by clinical laboratories or healthcare workers for testing in healthcare centres, not for home testing.»

3. Technical Specifications

Parameter Specification
Product type Rapid antigen test (TROD) for in vitro diagnostics
Analyte detected SARS-CoV-2 (COVID-19) – nucleocapsid protein (N) antigen
Detection method Lateral flow immunochromatography (colloidal gold), qualitative detection
Sample type Anterior nasal swab (NS); also suitable for oropharyngeal sample according to the manufacturer’s data sheet
Reading time Approximately 10 minutes
Interpretation Visual or automatic with OPERON LF Reader
Format Single-use device, simple/stick format
Intended use Professional: clinical laboratories and healthcare centres (not suitable for self-diagnosis)
Detection window First 5 days from symptom onset
Reference method RT-PCR
Presentation Box of 20 units, nasal swabs included
Storage 2–30 °C, in sealed packaging, protected from moisture
Shelf life 24 months
Certification CE-IVD marking (Directive 98/79/EC and RD 1662/2000) · Manufactured under ISO 13485
Manufacturer OPERON S.A. (Spain)

Diagnostic performance (concordance with RT-PCR)

Parameter Value
Sensitivity (concordance) 96.4 %
Specificity (concordance) 100 %
Total concordance 99.4 %
Limit of detection (LOD) 6 × 10² TCID50/mL (1.63 × 10⁵ copies/mL)

DOWNLOAD TECHNICAL DATA SHEET

4. Equivalences and Cross-References

The commercial reference of Cahnos for this product is 181001. The official OPERON order code for the 20-unit presentation could not be verified in public sources and must be confirmed directly with the manufacturer before use in tenders. There is no cross-reference equivalence table validated by the manufacturer OPERON S.A. relating this reference to codes from other brands; the references indicated below are functional category comparisons verified against technical data sheets and authorised catalogues, and are not interchangeable 1:1. Before any substitution, the device format (stick versus cassette), the authorised sample type, the reading time, the intended use (professional versus self-testing) and the performance data must be checked.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
ACON Biotech – Flowflex™ SARS-CoV-2 Rapid Antigen Test (professional TROD, cassette) L031-11815 Comparable by category (not interchangeable 1:1) Same analyte (nucleocapsid protein) and same lateral flow technique, but cassette format (not stick), nasal and nasopharyngeal sample, reading in 15 minutes and pack of 25 kits.
ACON Biotech – Flowflex™ SARS-CoV-2 Rapid Antigen Test (cassette, nasal sample) L031-11845 Comparable by category (not interchangeable 1:1) Presentation of 1 test per kit and 20 kits per box; cassette format and nasal sample only; same antigen technique.
Multipathogen respiratory panel Combined Rapid Test SARS-CoV-2 / Influenza A / Influenza B / RSV / Adenovirus IRT-545 Comparable by category (not interchangeable 1:1) Expanded panel that also detects influenza A/B, RSV and adenovirus in the same sample; broader spectrum than the monovalent test, cassette format and reading in ~15 minutes.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Professional COVID-19 screening: this monovalent test in stick format is the simplest and most direct option when only SARS-CoV-2 coverage is needed at the point of care, with a result in approximately 10 minutes and no additional equipment.
  • Optional automatic reading: if your laboratory handles a high volume of determinations, the result is compatible with automatic reading using the OPERON LF Reader, which reduces variability in visual interpretation.
  • Variant detection: by detecting the nucleocapsid protein, the test maintains its diagnostic capability against circulating variants; in the event of a positive result, always confirm by RT-PCR before making therapeutic or isolation decisions.
  • Seasonal differential diagnosis: if your centre also needs to distinguish influenza A/B, RSV or adenovirus in a single sample, consider the combined panels in the catalogue (e.g. COIF-522 / COIF-522C, IU-COVTESG-8 or IRT-545 / IRT-545-1).
  • Volume and budget: the presentation of 20 units per box optimises the cost per determination in screening campaigns; contact our sales team for special conditions on volume orders.
  • Storage: keep the kit in its sealed packaging at room temperature (2–30 °C), protected from moisture, and always respect the expiry date indicated.

Additional information

Product type

Rapid antigen test (TROD) for in vitro diagnostics

Detection method

Lateral flow immunochromatography (colloidal gold)

Analyte detected

SARS-CoV-2 nucleocapsid protein (N) antigen

Sample type

Anterior nasal swab (NS); suitable for oropharyngeal sample

Result time

Approximately 10 minutes

Reading

Visual or automatic with OPERON LF Reader

Format

Single-use device (simple/stick)

Scope of use

Professional – clinical laboratories and healthcare centres (not for self-diagnosis)

Presentation

Box of 20 units, swabs included

Detection window

First 5 days from symptom onset

Sensitivity

96.4 % (concordance)

Specificity

100 % (concordance)

Detection limit

6 × 10² TCID50/mL (1.63 × 10⁵ copies/mL)

Storage

2–30 °C in sealed packaging

Shelf life

24 months

Regulatory standard

CE-IVD (Directive 98/79/EC) · ISO 13485

Manufacturer

OPERON S.A. (Spain)

Method

Lateral flow immunochromatography (colloidal gold)

Use

Professional use in healthcare centre (not suitable for self-diagnosis)

Reference method

RT-PCR

Certifications

CE-IVD (Directive 98/79/EC and RD 1662/2000) · ISO 13485

Code cahnos

181001

Reviews

There are no reviews yet.

Be the first to review “Operon SIMPLE/STICK Ag SARS-CoV-2 COVID-19 Rapid Antigen Test – Qualitative Detection of Nucleocapsid Antigen in Nasal Swab, Lateral Flow Immunochromatography (CE-IVD), Professional Use in Healthcare Settings, Box of 20 Units”

Your email address will not be published. Required fields are marked *