Description
1. Introduction
The CRP (C-reactive protein) test in cassette is the reference diagnostic solution for the rapid assessment of inflammatory processes at the point of care. Specifically designed for the fluorescence immunoassay analyser Ref. 24600, it provides immediate, reliable and reproducible results without the need for large equipment or laboratory infrastructure. It is the ideal choice for medical practices, emergency services, primary care, clinical laboratories and community pharmacies that require a rapid and objective response when inflammation or infection is suspected.
2. Technical explanation of the test
C-reactive protein (CRP) is an acute-phase marker synthesised in the liver whose concentration rises early in response to infections, inflammatory processes, tissue damage or surgical stress, making it a key clinical tool for guiding the differential diagnosis between bacterial and viral aetiology and for monitoring patient progress. This cassette is ready to use: the capillary sample is obtained using the included safety lancet and applied to the cassette with the precision droppers; the cassette is then inserted into the Ref. 24600 analyser, which performs the reading by fluorescence immunoassay and provides the result immediately and objectively, eliminating the subjectivity of visual interpretation. The kit includes all the elements necessary for the determination: identification card (batch identification and calibration), reaction cassette, buffer solution, safety lancets and two precision droppers of 75 µl and 10 or 20 µl.
3. Technical specifications and product data
| Parameter | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 24605 (SKU Cahnos: GM24605) |
| Parameter detected | C-reactive protein (CRP) – inflammatory marker |
| Technology | Fluorescence immunoassay (cassette test) |
| Compatibility | Immunofluorescence analyser Ref. 24600 |
| Results | Immediate, with objective reading on the analyser |
| Sales unit | Box of 10 units (box of 10 pcs) |
| Device type | IVD – Professional use (IVD – Professional Use) |
| CND | W0102160601 |
| EAN | 6936983173070 |
Kit contents
| Item | Description |
|---|---|
| Identification card | ID Card (batch identification and calibration) |
| Test cassette | Ready to use |
| Buffer solution | Buffer |
| Safety lancets | For obtaining capillary blood samples |
| Precision droppers | 2 droppers: 75 µl + 10 or 20 µl |
Range of cassette tests for the analyser Ref. 24600
| Parameter | Reference | Category |
|---|---|---|
| CRP | 24605 | Inflammatory markers |
| Procalcitonin (PCT) | 24606 | Inflammatory markers |
| D-dimer | 24608 | Coagulation |
| Troponin I (cTnI) | 24610 | Cardiac |
| Renal insufficiency (N-GAL) | 24612 | Nephrology |
| Glycated haemoglobin (HbA1c) | 24614 | Diabetes |
| Influenza A/B | 24618 | Infectious diseases |
| Strep A | 24619 | Infectious diseases |
| VRS/RSV | 24620 | Infectious diseases |
| COVID-19 (antigen) | 24622 | Infectious diseases |
| COVID-19 (antibodies) | 24623 | Infectious diseases |
| Vitamin D | 24625 | Vitamins |
4. Equivalences and Cross-References
The cassette system for the 24600 analyser is a closed system: no direct equivalents with cassettes from other manufacturers have been verified in reliable sources for this reference. To guarantee the reliability of results, this test (reference 24605, SKU Cahnos GM24605) must be used exclusively with the Ref. 24600 analyser and is not interchangeable with lateral flow rapid tests with visual reading or with reagents from other platforms without previously validating compatibility. The same family of cassettes for this analyser, available in the Cahnos catalogue, includes: CRP test (GM24605), procalcitonin test (GM24606), D-dimer test (GM24608), cTnI Troponin I test (GM24610), renal insufficiency test (GM24612), glycated haemoglobin test (GM24614), Influenza A/B test (GM24618), Strep A test (GM24619), RSV test (GM24620), COVID-19 test in its antigen (GM24622) and antibody (GM24623) variants, and vitamin D test (GM24625). For the detection of the same biomarker in a rapid lateral flow test (TROD) format without an analyser, Cahnos offers references CCR-U402 (semi-quantitative test, box of 10) and GM24527 (semi-quantitative CRP test, box of 20), which share the same clinical indication with different technology. Contact our technical-commercial team to confirm availability and replenishment references.
5. Selection tips and variants of interest
Verify that you have the Ref. 24600 analyser for the use of this cassette, as it is specifically designed for this immunofluorescence platform. The presentation in a box of 10 units is the manufacturer’s standard sales unit and allows continuous replenishment planning of all parameters of your diagnostic panel from a single platform of up to 12 tests. This test is especially useful in emergency departments, primary care and internal medicine, and can be combined with other markers in the range, such as procalcitonin (GM24606), to complete the assessment of patients with suspected infection. If your facility does not have an analyser, consider the visual reading alternatives for the same clinical indication (CCR-U402 or GM24527). Request a quote from our technical-commercial team to plan your consumables orders and ensure the supply of the different tests in the range. For any questions about compatibility or selection of variants, our team is at your disposal.





Reviews