We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

5-lumen anorectal manometry and compliance catheter – Perfusion catheter for rectal and anal pressure recording (L 120 cm, Ø 6.6 mm / 20 CH) | C74U

Price on request

5-lumen anorectal manometry and compliance catheter (ref. C74U) designed to perform standard anorectal manometry and rectal compliance measurement in a single examination. It incorporates 2 ports dedicated to balloon inflation and 3 infusion ports located at 4-9 and 10 cm from the distal end, allowing simultaneous and accurate recording of rectal and anal pressure. With an approximate length of 120 cm and a diameter of 6.6 mm (20 CH), it is the ideal equipment for functional diagnosis of the pelvic floor, motility assessment and distensibility studies in gastroenterology and digestive physiology units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
C74U

Description

Anorectal manometry and compliance in a single examination

The 5-lumen anorectal manometry and compliance catheter (ref. C74U) is an integral solution for the functional diagnosis of the pelvic floor. Its configuration combines standard anorectal manometry with the measurement of rectal compliance (distensibility), allowing both examinations to be completed in a single session and optimising study time and patient comfort. It is the recommended choice for gastroenterology departments, digestive physiology units, colorectal surgery and motility laboratories seeking precision, repeatability and clinical versatility.

Technical explanation of the device and procedure

The C74U catheter is inserted rectally and, once positioned, the distension balloon is inflated through its 2 dedicated ports to distend the rectal wall and measure the pressure exerted by the rectum on the balloon; this evaluates compliance and produces the rectometrogram. Simultaneously, its 3 infusion ports, located at 4-9 and 10 cm from the distal end, are perfused with sterile water at a constant flow rate and connected to the transducers of the recording system to obtain rectal and anal canal pressure curves. The independent lumens prevent interference between the inflation and measurement channels, ensuring stable, reproducible and clinically reliable pressure curves throughout the anorectal motility study.

Technical specifications

The main features of the C74U catheter are summarised in the following tables:

Characteristic Specification
Configuration 5 functional lumens (standard manometry + compliance)
Balloon ports 2 ports dedicated to inflation of the distension balloon
Infusion ports 3 ports at 4-9 and 10 cm from the distal end
Length L ≈ 120 cm
Diameter Ø 6.6 mm (20 CH)
Indication Standard anorectal manometry and compliance measurement in a single examination
Port Function
Ports 1-2 Balloon inflation for measuring the pressure exerted by the rectum
Port 3 Infusion at 4-9 cm from the distal end for anal/rectal pressure recording
Ports 4-5 Infusion at 10 cm from the distal end for rectal pressure recording

Equivalences and cross-references

The C74U meets the standard for multi-channel balloon-perfused catheters for anorectal manometry and compliance used by the main manufacturers of digestive motility equipment. It is functionally equivalent to the perfused anorectal measurement catheters from the urodynamics series of the Rüsch / Teleflex group (colour-coded accessory connection, sterile, single-use and latex-free) and to the balloon-type water-perfused catheters from manufacturers such as Laborie and Albyn Medical, in 5-lumen configurations for simultaneous recording of rectal pressure, sphincter pressure and compliance. In the Cahnos catalogue, the graduated variant with radiopaque markers of this same configuration is the C56U; for compliance-only studies, refer to the bidirectional rectal compliance catheter C55U.

Selection tips and variants of interest

Select the C74U when you need to study, in a single insertion, the resting and contraction pressure of the anal canal, rectal sensitivity and rectal compliance. If radiographic location of the measurement points is required, consider the graduated manometry and compliance catheter C56U (orifices with radiopaque markers). For higher-resolution motility studies, the following catheters are available: the 4-lumen Arhan model (C54U), the graduated 5-lumen (C66U), the paediatric (C69U) and the 7-lumen adult (C91AU). For bubble-free balloon filling, complement with the C57U filling needle. Cahnos supplies on request and with a formal quotation. Always verify the compatibility of connectors and transducers with your manometry equipment.

Additional information

Functional lumens

5 lumens (2 for balloon inflation + 3 for infusion)

Balloon ports

2 ports dedicated to inflation of the distension balloon

Infusion ports

3 ports at 4-9 and 10 cm from the distal end

Length

L ≈ 120 cm

Diameter

Ø 6.6 mm (20 CH)

Perfusion system

Sterile water at constant flow rate for pressure recording

Indications

Standard anorectal manometry and compliance measurement in a single examination

Type of use

Reusable with reprocessing according to the manufacturer's protocol

Reviews

There are no reviews yet.

Be the first to review “5-lumen anorectal manometry and compliance catheter – Perfusion catheter for rectal and anal pressure recording (L 120 cm, Ø 6.6 mm / 20 CH) | C74U”

Your email address will not be published. Required fields are marked *