5-channel graduated anorectal manometry and compliance catheter with radiopaque markers – Perfusion catheter for rectal and sphincter pressure (L 120 cm, Ø 6.6 mm / 20 CV) | C56U

Price on request

5-channel graduated anorectal manometry and compliance catheter (ref. C56U), designed to record anal motility by perfusion and measure rectal distensibility (compliance) in a single examination. It incorporates a graduated balloon to distend the rectum and three strategically positioned measurement orifices: rectal pressure at 1.5 cm and sphincter pressure at 6 and 7 cm above the balloon, allowing a complete profile of the anorectal canal to be obtained. With an approximate length of 120 cm and a diameter of 6.6 mm (20 CV), all its orifices include radiopaque markers for precise radiographic localisation. The recommended choice for gastroenterology departments, digestive physiology units and motility laboratories.

International shipping. Import duties and taxes are payable by the recipient.

Reference
C56U

Description

Anorectal manometry and compliance in a single catheter

The 5-channel graduated anorectal manometry and compliance catheter (ref. C56U) is an advanced technical solution for the comprehensive diagnosis of anorectal function. Its design combines the recording of anal motility by perfusion with the measurement of rectal distensibility (compliance), allowing both examinations to be completed in a single session and optimising study time and patient comfort. It is the recommended choice for gastroenterology departments, digestive physiology units, motility laboratories and specialised clinics in pelvic floor diagnostics.

Technical explanation of the device and procedure

The catheter is inserted rectally and, once positioned, the graduated distension balloon is inflated to distend the rectal wall and assess sphincter function, simultaneously recording the pressure exerted by the organ on the balloon. Its three measurement orifices, located on the balloon, are perfused with sterile water at a constant flow rate and connected to the transducers of the recording system: rectal pressure is measured at 1.5 cm above the balloon and sphincter pressure at 6 cm and 7 cm above it, allowing a complete pressure profile of the anorectal canal to be constructed. The independent lumens prevent interference between the inflation and measurement channels, ensuring stable, reproducible and clinically reliable pressure curves throughout the motility study.

Technical specifications

The main features of the C56U catheter are summarised in the following tables:

Characteristic Specification
Configuration 5 channels (perfusion manometry + compliance)
Distension balloon Graduated, to distend the rectum and assess sphincter function
Measurement ports 3 orifices positioned on the balloon
Rectal pressure position 1.5 cm above the balloon
Sphincter pressure position 6 cm and 7 cm above the balloon
Radiographic identification Radiopaque markers on all orifices
Length L ≈ 120 cm
Diameter Ø 6.6 mm (20 CV)
Measurement system Sterile water perfusion
Indication Anorectal manometry and study of rectal distensibility (compliance)

Functional distribution of orifices and channels:

Port / Channel Function
Orifice 1 Rectal pressure measurement at 1.5 cm above the balloon
Orifices 2 and 3 Sphincter pressure measurement at 6 cm and 7 cm above the balloon
Balloon channels Inflation of the graduated distension balloon
Markers Radiopaque on all orifices for radiographic localisation

Equivalences and cross-references

The C56U meets the standard of the multi-channel perfusion catheter with balloon for anorectal manometry and compliance used by the main manufacturers of digestive motility equipment. It is functionally equivalent to the C74U, the non-graduated version of this same 5-channel configuration (L 120 cm and Ø 6.6 mm / 20 CH), and to the water-perfused balloon catheters from companies such as Laborie and Albyn Medical in 5-channel configurations for simultaneous recording of rectal pressure, sphincter pressure and compliance. It is also related to the perfused anorectal measurement catheters of the Rüsch / Teleflex group’s urodynamics series (colour-coded accessory connection, sterile and latex-free). In the Cahnos catalogue, it is complemented by the bidirectional compliance rectal catheter C55U for exclusive distensibility studies and by the cystomanometry catheters U10S and U11S for complete urodynamic assessments.

Selection tips and variants of interest

Select the C56U when you require reliable radiographic localisation of the measurement points, thanks to its graduation and the radiopaque markers on all its orifices. If you do not need radiographic reference, the C74U offers the same functional 5-channel configuration. For higher-resolution motility studies, the 4-channel Arhan model (C54U), the graduated 5-channel catheter (C66U), the paediatric one (C69U) and the 7-channel adult one (C91AU) are available. For bubble-free balloon filling, complement the equipment with the C57U filling needle. Always verify the compatibility of connectors and transducers with your manometry system; at Cahnos we supply on request and with a formal quotation with special conditions for B2B professionals.

Additional information

Configuration

5 channels (perfusion manometry + compliance)

Measurement ports

3 orifices on the balloon

Rectal pressure position

1.5 cm above the balloon

Sphincter pressure position

6 cm and 7 cm above the balloon

Balloon

Graduated, for distension

Radiopaque markers

Yes, in all orifices

Length

L ≈ 120 cm

Diameter

Ø 6.6 mm (20 CV)

Measurement system

Sterile water perfusion

Indications

Anorectal manometry and rectal compliance (distensibility)

Use

Functional anorectal diagnostics in gastroenterology

Reviews

There are no reviews yet.

Be the first to review “5-channel graduated anorectal manometry and compliance catheter with radiopaque markers – Perfusion catheter for rectal and sphincter pressure (L 120 cm, Ø 6.6 mm / 20 CV) | C56U”

Your email address will not be published. Required fields are marked *