We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

SpO₂ wrap-around wristband sensor (Wrapsensor) for PalmCare DUO, M800, M850, M860, M880, M8500 and Q5 – APK Technology – 1.5 m cable (Ref. MEC21.13-5204)

69,00 €

Sensor SpO₂ Wrapsensor wrap-around wristband from APK Technology for continuous, non-invasive monitoring of oxygen saturation (SpO₂) and pulse rate. Its flexible wrap-around design adapts comfortably to the measurement point, offering a reliable and stable alternative to classic forceps sensors, even during prolonged monitoring or in patients with reduced mobility. Suitable for adults and children, it includes a 1.5 m cable and is compatible with PalmCare DUO, M800, M850, M860, M880, M8500 and Q5 monitors. Original replacement distributed by Cahnos via medical ECONET GmbH. References: MEC21.13-5204 / 21.13-5204. Product on quotation.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC21.13-5204

Description

1. Introduction

The SpO₂ Wrapsensor from APK Technology is the reference accessory for completing the monitoring of your patient monitors in the PalmCare range and the M series. Its wrap-around wristband design adapts flexibly to the measurement point and provides a comfortable and reliable alternative to classic forceps sensors, especially in patients with reduced mobility, delicate tissue, or when an alternative measurement position is required during continuous monitoring.

An original hospital-grade replacement part, distributed by Cahnos via medical ECONET GmbH, ideal for replenishing or expanding the sensor fleet in your department. Suitable for adult and paediatric patients.

2. Technical explanation

This sensor uses the non-invasive technique of pulse oximetry: two light emitters (red and infrared) pass through the patient’s vascular bed, and a photodetector records variations in absorption of the pulse wave. With this data, the monitor calculates real-time oxygen saturation (SpO₂) and pulse rate values.

Unlike clip sensors that attach to the finger, the wrap-around wristband format is placed flexibly over the measurement point, ensuring stable contact and high-quality signal even during prolonged monitoring. With a cable length of 1.5 metres, it offers an adequate range for the patient’s bedside and facilitates positioning relative to the monitor without compromising signal accuracy.

3. Technical Specifications

The manufacturer’s specifications are detailed below:

Product type SpO₂ wrap-around wristband sensor (SpO₂ Wrapsensor)
Measured parameters Oxygen saturation (SpO₂) and pulse rate
Cable length 1.5 m
Target population Adults and children (Für Erwachsene und Kinder)
Brand / manufacturer APK Technology
Original distributor medical ECONET GmbH
Category in the ECONET catalogue Diagnostics/Therapy | Pulse oximetry | Accessories

Monitor compatibility: this sensor is compatible with the following models:

Family/Series Compatible models
PalmCare PalmCare DUO
M series M800, M850, M860, M880, M8500, Q5

Available references:

Reference Description
MEC21.13-5204 Cahnos reference (SKU) / order reference for the SpO₂ Wrapsensor
21.13-5204 Article number medical ECONET / reference APK Technology

4. Equivalences and Cross-References

This sensor corresponds to references MEC21.13-5204 and 21.13-5204, both of the same article from APK Technology distributed by medical ECONET GmbH. There is no official equivalence table validated by the manufacturer that authorises a 1:1 replacement with generic sensors from other brands; connector compatibility and the reading protocol must always be verified against the specific monitor before any replacement.

Within the same family of SpO₂ sensors from APK Technology, the catalogue includes other complementary variants: the Wrapsensor for the PROview and AnyView series (ref. MEC21.13-5268, 3 m cable), the Wrapsensor for the M10, M20, Compact and PalmCare Pro/Plus monitors (ref. MEC21.13-5267, 3 m cable), the disposable paediatric Wrapsensor (ref. 21.13-5276, 9-pin connection with adapter cable) and the Soft Touch and paediatric finger clip sensors (refs. 21.13-5270 and MEC21.13-5272).

5. Selection tips and variants of interest

Always verify the exact model of your monitor before ordering the replacement: this reference is intended for PalmCare DUO, M800, M850, M860, M880, M8500 and Q5. For other monitor families (PROview, AnyView, M10, M20, Compact, etc.), consult the corresponding Wrapsensor variant, as connector compatibility varies depending on the equipment model.

The wrap-around wristband format is the recommended option when an alternative to the forceps sensor is required, or a more stable and comfortable measurement position during prolonged monitoring. Its reusable design, suitable for adults and children, makes it a versatile solution for emergency departments, hospitalisation and continuous monitoring. For paediatric patients in other ranges, Soft Touch, finger clip and disposable wristband (Einweg) versions are available, each with its specific cable length and connection type.

This product is sold on a quotation basis: for institutional orders, fleet provisioning or tenders, contact our technical-commercial team at Cahnos, who will advise you on reference MEC21.13-5204 and the most suitable variants for your equipment fleet.

Additional information

Sensor type

SpO₂ wrap-around wristband sensor (Wrapsensor)

Manufacturer

APK Technology

Manufacturer reference

MEC21.13-5204 / 21.13-5204

Cable length

1.5 m

Target population

Adults and children

Measured parameters

Oxygen saturation (SpO₂) and pulse rate

Compatibility

PalmCare DUO, M800, M850, M860, M880, M8500, Q5

Reviews

There are no reviews yet.

Be the first to review “SpO₂ wrap-around wristband sensor (Wrapsensor) for PalmCare DUO, M800, M850, M860, M880, M8500 and Q5 – APK Technology – 1.5 m cable (Ref. MEC21.13-5204)”

Your email address will not be published. Required fields are marked *