We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Nellcor Compatible Infant SpO₂ Catheter (3–20 kg) – Box of 10 units – Ref. 33756

75,05 €

Disposable paediatric SpO₂ pulse oximeter catheter (ref. 33756), compatible with monitors with Nellcor technology (Oxisensor protocol; not compatible with Nellcor Oximax) and designed for patients from 3 to 20 kg. Each sensor is supplied in sterile single-use packaging with a 70 cm cable, ensuring maximum hygiene and eliminating the risk of cross-contamination in paediatrics, emergency departments, paediatric ICU and clinics. Reliable measurement of oxygen saturation (SpO₂) in the range 70–100 % with accuracy of ±2 %, and pulse rate from 30–250 lpm with accuracy of ±2 lpm or ±2 %. Presentation in box of 10 units. Class II B medical device (CND C900301): consult our technical-commercial team. For large orders you can request a quote.

Sales unit: caja de 10
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33756

Description

1. Commercial Introduction

The disposable paediatric SpO₂ pulse oximeter catheter (ref. 33756) is the monitoring solution indicated for controlling blood oxygen saturation (SpO₂) and pulse rate in paediatric patients from 3 to 20 kg, with full compatibility with monitors using Nellcor technology (Oxisensor protocol; not compatible with Nellcor Oximax).

Presented in a box of 10 units, it is the ideal consumable for hospitals, paediatric clinics, emergency departments, paediatric ICU and primary care: being single-use and supplied in sterile packaging with a 70 cm cable, it eliminates the risk of cross-contamination between patients and facilitates stock rotation in high-demand units.

2. Technical explanation

Pulse oximetry is a non-invasive technique that measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry: the sensor incorporates two light-emitting diodes —red and infrared— that pass through the patient’s vascular bed. Since oxygenated and deoxygenated haemoglobin absorb light differently, the monitor calculates the saturation percentage (SpO₂) and pulse rate from the differential absorption and the plethysmographic waveform.

This disposable paediatric catheter follows the electrical scheme and communication protocol of Nellcor standard (Oxisensor) SpO₂ sensors, so it connects directly to most bedside, transport and multiparameter monitors compatible with this system. Its adhesive design, adapted to the paediatric patient’s anatomy, allows comfortable and stable placement during continuous monitoring.

3. Technical Specifications

Disposable SpO₂ pulse oximeter sensor for paediatric patients from 3 to 20 kg. Each sensor is supplied in sterile packaging with a 70 cm cable.

Measurement specifications

Parameter Specification
SpO₂ measurement range 70 %–100 %
SpO₂ accuracy 70 %–100 %: ±2 %; below 70 %: not specified
Pulse measurement range 30–250 lpm
Pulse accuracy ±2 lpm or ±2 % (whichever is greater)
Optical sensor Red light: 650–670 nm, 6.65 mW · Infrared: 880–910 nm, 6.75 mW
Compatibility Pulse oximetry monitors and modules with Nellcor technology (Oxisensor protocol). Not compatible with Nellcor Oximax sensors or equipment

Product data

Manufacturer GIMA
Sales unit Box of 10 units (box of 10 pcs)
Device type Medical device (Medical device)
Device class II B
CND C900301
EAN 6945040104339
Manufacturer reference 33756 (SKU Cahnos GM33756)
Sterilisation Sterile packaging, single-use
Cable length 70 cm

4. Equivalences and Cross-References

This catheter corresponds to factory reference 33756 (SKU Cahnos GM33756) and follows the profile of Nellcor Oxisensor standard disposable paediatric adhesive sensors. For its patient population (3–20 kg), its functional reference equivalent is the Nellcor I-20 sensor (Oxisensor II), with the same weight profile and DB9 9-pin connector; the infant sensor from the OxiMax family (MAX-I) shares the patient profile but requires OxiMax technology, which is incompatible with this product.

Within the range of Nellcor-compatible disposable SpO₂ sensors (CND C900301, presentation in box of 10 units), the family is completed with the adult catheter 33754 (>30 kg), the paediatric catheter 33757 (10–50 kg) and the multifunction catheter 33755 (neonate <3 kg and adult >40 kg). In the Cahnos catalogue, the infant SpO₂ sensor with 9-pin connector (ref. 18633) constitutes a comparable alternative with a 3–20 kg profile. There is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference with other brands; before replacing a catheter in use, confirm the exact make and model of your monitor and the specific protocol (Oxisensor/OxiMax) with our technical-commercial department.

5. Selection tips and variants of interest

Select this paediatric catheter for patients from 3 to 20 kg. For lower weight patients, consider the multifunction catheter 33755 (neonate <3 kg and adult >40 kg); for paediatric population from 10 to 50 kg, the catheter 33757; and for adult patients over 30 kg, the catheter 33754. If your centre prefers reusable sensors for spot monitoring, the reusable paediatric catheters of the same brand are an alternative to consider.

Always verify monitor compatibility (make, model and Nellcor protocol) before placing the order. As this is a single-use product, do not reuse or reprocess the sensor; store it in a dry place, protected from direct sunlight and extreme temperatures. For volume orders, supply contracts or tenders, contact our technical-commercial team at Cahnos.

Additional information

Manufacturer reference

33756

Sensor type

Disposable infant SpO2 catheter (3-20 kg) with adhesive fixation

Compatibility

Monitors with Nellcor technology (Oxisensor protocol). Not compatible with Nellcor Oximax

Patient population

Infant / paediatric 3 to 20 kg

Presentation

Box of 10 units

Sterilisation

Sterile packaging, single-use

Cable length

70 cm

SpO2 range

70 %–100 %

Spo2 accuracy

70 %–100 %: ±2 %; below 70 %: not specified

Pulse range

30–250 lpm

Pulse accuracy

±2 lpm or ±2 % (whichever is greater)

Device type

Medical device (Medical device)

CND code

C900301

EAN

6945040104339

Sales unit

Box of 10 units (box of 10 pcs)

Presentacion

Box of 10

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable Nellcor Compatible Infant SpO₂ Catheter (3–20 kg) – Box of 10 units – Ref. 33756”

Your email address will not be published. Required fields are marked *