Description
1. Commercial Introduction
The adult SpO2 catheter (ref. 35149) is the manufacturer’s original replacement for the CMS 8000 patient monitor (code 35151). Designed for adult patients, it is the ideal solution for hospitalisation services, emergency departments, observation wards, outpatient clinics and intermediate care units that need to renew the pulse oximetry sensor without replacing the complete equipment. As an original quality spare part, it guarantees connector compatibility with your monitor and signal reliability in every measurement. For large orders you can request a quote: contact our technical-commercial team for B2B terms and availability.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry. The catheter integrates an emitter and photodetector in a single element: the emitter projects red and infrared light through the patient’s vascular bed and the detector quantifies the differential absorption according to the degree of blood oxygenation, transmitting the signal to the monitor, which processes and displays the values in real time. This reusable adult catheter incorporates an integrated 3-metre cable that connects directly to the SpO2 port of the CMS 8000 monitor, allowing rapid, stable and comfortable placement on the adult patient, for both spot and continuous monitoring.
3. Technical Specifications
This part is supplied as a replacement (spare) for the original catheter of the CMS 8000 patient monitor (code 35151). Always verify the reference of your equipment before requesting the replacement.
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040101703 |
Technical features
| Parameter | Specification |
|---|---|
| Manufacturer reference | 35149 |
| Catheter type | Reusable adult SpO2 catheter (adult probe) |
| Patient population | Adult |
| Cable length | 3 m |
| Compatibility | Patient monitor CMS 8000 (code 35151) |
| Use | Replacement (spare) |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM35149 | Adult SpO2 catheter for CMS 8000 patient monitor (code 35151) – Replacement with 3 m cable (ref. 35149) | 1 pc |
4. Equivalences and Cross-References
Reference 35149 is a manufacturer-specific catalogue code for this replacement adult SpO2 catheter. The manufacturer uses proprietary connectors by equipment family, so we do not have a manufacturer-validated equivalence table that cross-references this catheter with codes from other brands on a 1:1 interchangeable basis. Before replacing any pulse oximeter catheter, always verify the connector and communication protocol compatibility with the exact brand and model of your equipment. Within the same range, similar category references are the replacement adult catheter for pulse oximeters 35152 and 35213 (ref. 35153), the adult SpO2 catheter for monitor 35111 up to serial number 24030200202 (ref. 35118), and the reusable paediatric catheter for equipment 35100 and 35101 (ref. 35106). These variants are similar by category and population, but not interchangeable with each other without verifying the connector and equipment model.
5. Selection tips and variants of interest
Check your monitor: this catheter is indicated for the CMS 8000 patient monitor (code 35151). Always provide the full reference of your equipment to confirm compatibility before placing the order. Choose the correct population: for adult patients this is the indicated catheter; for paediatric or neonatal populations you should consider the specific catheters in the range. Maintenance: clean the catheter between patients with a soft cloth or compatible disinfectant solution, without submerging it, and keep the cable free of sharp bends to prolong its service life. Stock management: as an official replacement part, we recommend keeping one replacement unit per equipment to avoid interruptions in patient monitoring. B2B terms: Contact our technical-commercial department at Cahnos for terms, lead times and availability.




Reviews
There are no reviews yet.