Description
1. Introduction
The adult SpO₂ pulse oximetry sensor (ref. 35262) is the practical and reliable solution for departments that need to continuously monitor blood oxygen saturation and pulse rate with equipment compatible with Nellcor Oximax technology. Designed as a finger sensor for adult patients and with an integrated 0.9 m cable, it is a reference consumable for hospitals, intensive care units, emergency departments, operating theatres, resuscitation and hospital wards working with bedside, transport and multiparameter monitors.
As a product in the range, it comes with the warranty of an established manufacturer in the medical supplies sector, with full traceability (EAN 6900234100450) and classification as a class II B medical device.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO₂). The sensor emits light at two wavelengths — red and infrared — through the vascular bed of the finger, and a photodetector quantifies the light absorbed by the tissues. The pulsatile component of the signal, generated by the arterial heartbeat, allows the percentage of saturated haemoglobin and the pulse rate to be calculated in real time.
This sensor is specifically designed for the adult population (finger type), with comfortable and stable fixation during continuous monitoring. Its integrated 0.9 m cable connects directly to monitors compatible with the Nellcor Oximax protocol, and can be extended with the 2.4 m extension cable (ref. 35305) for greater patient freedom of movement or better management of the monitoring station.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 35262 |
| Sensor type | Finger sensor for adult patients |
| Monitoring parameters | Oxygen saturation (SpO₂) and pulse rate |
| Cable length | 0.9 m |
| Compatibility | Nellcor Oximax: N-550, N-560, N-595, N-600 and patient monitors with Oximax module |
| Extension cable (2.4 m) | Ref. 35305 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100450 |
Available references
| Reference | Description | Cable length |
|---|---|---|
| 35262 | Adult SpO₂ sensor compatible with Nellcor Oximax (this product) | 0.9 m |
| 35305 | Extension cable | 2.4 m |
4. Equivalences and Cross-References
Reference 35262 is the manufacturer’s management code for this adult finger sensor compatible with the Nellcor Oximax platform. Equivalences should not be treated as 1:1 interchangeable without prior verification, since the communication protocol and the connector must always be confirmed with the specific monitor installed at the facility.
| Family / Platform | Models / References | Relationship level | Observations |
|---|---|---|---|
| Nellcor Oximax | N-550, N-560, N-595, N-600 | Compatible platform | Monitors and equipment with Oximax module verified in the manufacturer’s catalogue. |
| Nellcor Oximax | Patient monitors with Oximax module | Compatible platform | Confirm the presence of the Oximax module on your multiparameter monitor. |
| Catalogue Cahnos | 35305 (extension cable 2.4 m) | Compatible accessory | Official extension cable indicated by the manufacturer for this sensor. |
Within the Cahnos catalogue you will find other pulse oximetry sensors compatible with Nellcor systems (references 18631, 18632, 18633 and 18634, with 9-pin DB9 connector) that can serve as a reference for comparing families, although the connector and protocol (Oxisensor/OxiMax) must always be validated with the equipment at the facility. There is no manufacturer-validated equivalence table cross-referencing this reference with specific codes from other brands; please consult our technical-commercial department before using it in tenders.
5. Selection tips and variants of interest
- Compatibility check: although the sensor is designed for the OxiMax platform, always state the exact brand and model of the monitor to confirm compatibility before placing the order.
- Cable length: with 0.9 m the sensor is ideal for monitoring stations close to the patient; if you need greater reach, add the 2.4 m extension cable (ref. 35305).
- Population: this model is intended for adult patients (finger type). For paediatric, infant or neonatal patients, consider other families of sensors compatible with your system.
- Storage: store the sensor in a dry place, protected from direct sunlight and extreme temperatures; follow the manufacturer’s instructions for use for cleaning and maintenance.
- Stock management: as it is a reusable consumable intended for continuous adult monitoring, it is advisable to plan replacement stock for high-turnover units. Ask our team about B2B volume conditions.





Reviews
There are no reviews yet.