Description
1. Introduction
The adult finger SpO₂ pulse oximeter sensor (soft type), reference 35260, is the ideal replacement and consumable for departments that monitor blood oxygenation with monitors compatible with Nellcor technology. Its soft finger design ensures comfortable and stable contact on the capillary bed of the adult patient, with a 0.9 m cable that facilitates direct connection to the monitor. It is a class II B medical device supplied with a manual in Spanish, French, English and Italian, ready for integration in hospitals, clinics, emergency departments, ICUs and patient transport.
2. Technical explanation
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed of the finger and detects the differential absorption according to the degree of blood oxygenation. The signal is transmitted to the monitor via an electrical scheme compatible with the Nellcor standard, allowing direct integration into the wide range of equipment listed in the compatibility block (Artema, Datascope/Mindray, Dräger, GE Medical, Invivo, Ivy Biomedical, Mennen, Nellcor, Nihon Kohden, Pace Tech and Philips). The sensor incorporates a soft fixation point for the adult patient’s finger and accepts an optional extension cable (code 35304) to increase the distance to the monitor when necessary.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100078 |
Technical features
| Manufacturer reference | 35260 (sensor) / 35304 (optional extension cable) |
|---|---|
| Sensor type | Soft-finger sensor for adult patient |
| Compatibility | OEM – Nellcor brand |
| Cable length | 0.9 m |
| N | 2 |
| Extension cable | Code 35304, available |
| Documentation | Manual in ES, FR, IT, GB |
Monitor compatibility
Artema: Diascope; Datascope (Mindray): Accutorr Plus, Expert, Passport, PM-50; Dräger: Cicero, Narkomed, Vitalert 1000; GE Medical: Corometrics 118, 120, 129, 188, 510, 556, Critikon 9710, 9720, Plus, Compact, Dinamap Select, MPS, Oxyshuttle, Pro 300/400, Eagle Series, Dash Series, Hellige Eagle, 1000, 3000, Eagle SMK, SMU, SMV, SOLAR Series, TRAM Modular x50SL Series; Invivo Research: MI2 (Nellcor SpO2), Millennia 4500 Plus 2, Invivo/MDE Escort 100 OPT11A, Escort 300A, Escort II OPT30, Prism (Nellcor SpO2); Ivy Biomedical: 405A, 4050, 405P, 405T, Vital-Guard 450 CN; Mennen: Horizon XL (Nellcor SpO2), MR 1300 Mercury 1200; Nellcor: N100 (requires preamplifier cable), N180, N200 (requires preamplifier cable), N-20, NPB-75, NPB-290, NPB-295, N-390, N-395, N-3000, N6000; Nihon Kohden: BSM-1102 Life Scope EC, BSM2304 iPro (Life Scope i), BSM-4102, 4112 Procyon LT (Life Scope P), BSM-4104, 4114 Procyon (Life Scope P), BSM-9510 Life Scope M (Nellcor SpO2), OGS2000 PocketCare (Nellcor SpO2); Pace Tech Vitalmax 800 Series; Philips: 78352C, 78354C, 78834C, M1020A, M1025B, M1205A, M1350B, M1722A/B, M1732A/B, M2475B, M2601A, M3000A.
4. Equivalences and Cross-References
This sensor Ref. 35260 is supplied as OEM compatible with Nellcor technology and is designed to work with monitors that use this standard (see the compatibility list in block 3). There is no manufacturer-validated equivalence table that cross-references 1:1 this reference with codes from other brands: before any substitution, always verify the electrical scheme and protocol (Oxisensor/OxiMax) of your monitor with the technical department. As a direct complement to this product, it offers the extension cable code 35304 to increase the distance between the sensor and the monitor. In the Cahnos catalogue you will also find the family of Nellcor-compatible sensors with DB9 connector: adult sensor (ref. 18631), paediatric (ref. 18632), infant (ref. 18633) and adult/newborn (ref. 18634).
5. Selection tips and variants of interest
Select this adult finger sensor when your monitor is compatible with Nellcor technology and the patient is an adult: its soft fixation point maximises comfort and signal stability in continuous monitoring. If the monitor connection point is far from the bed or stretcher, add the extension cable code 35304 to gain distance without losing signal quality. Before placing the order, always confirm the exact brand and model of your monitor, as the Nellcor protocol has variants (Oxisensor/OxiMax) that must be verified. For other patient populations, consider the other Nellcor-compatible sensors in the Cahnos catalogue (adult, paediatric, infant and adult/newborn). For large orders you can request a quote: consult our technical-commercial team for B2B conditions for fleets, contracts and tenders.





Reviews
There are no reviews yet.