Description
1. Commercial Introduction
The adult finger SpO₂ pulse oximetry sensor compatible with Datascope (Ref. 35230) is the reliable replacement your service needs to keep the Datascope family monitors operational: Accusat, Accutorr 3/4 SAT, Accutorr Plus and Passport. It is a consumable of quality equivalent to the original accessory, designed for continuous and non-invasive monitoring of blood oxygen saturation (SpO₂) and pulse rate in adult patients, both on the hospital ward and in emergency, operating theatre and critical care. A practical solution to renew the fleet of sensors at your centre with maximum compatibility and at a very competitive cost per unit.
2. Technical Explanation
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry: the sensor emits light at two wavelengths through the vascular bed of the finger and detects differential absorption according to the degree of blood oxygenation, also calculating pulse rate. This sensor, of the adult patient finger clip type, connects to the Datascope monitor via a 0.9 m cable; for connection to the device, the extension cable (Ref. 35301) must be used, as indicated by the manufacturer. All products are supplied with instruction manuals in GB, FR, IT and ES.
3. Technical Specifications
Product data
| Brand | Datascope |
|---|---|
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100283 |
Technical features
| Sensor type | Adult patient finger clip (Adult Finger) |
|---|---|
| Cable length | 0.9 m |
| Extension cable | Ref. 35301 (required for connection to the device) |
| Compatibility | Accusat, Accutorr 3/4 SAT, Accutorr Plus, Passport (SpO₂ module) |
| Manufacturer reference | 35230 |
| Documentation | Manual in GB, FR, IT, ES |
4. Equivalences and Cross-References
This sensor corresponds to the original reference Ref. 35230, compatible with the indicated Datascope monitor family. For its use, the extension cable Ref. 35301 is essential, sold separately, which allows the sensor to be connected to the monitor’s SpO₂ module. There is no manufacturer-validated equivalence table cross-referencing this reference with codes from other brands on a 1:1 interchangeable basis; before replacing the sensor at your centre, always verify the exact make and model of the monitor to confirm compatibility.
5. Selection tips and variants of interest
Confirm the model of your Datascope monitor (Accusat, Accutorr 3/4 SAT, Accutorr Plus or Passport) and order the Ref. 35301 (extension cable) together with the sensor if your installation requires it to achieve connection to the device. For routine maintenance, clean the sensor surface between patients with a soft cloth following the manufacturer’s instructions and store the product in a dry place, protected from direct sunlight and extreme temperatures. For volume orders, supply contracts or needs for other patient populations (paediatric or adult with other cable lengths), consult our technical-commercial team at Cahnos, who will confirm the exact reference and B2B conditions.





Reviews
There are no reviews yet.