Adult Finger SpO₂ Pulse Oximeter Sensor Compatible with Datascope (Accusat, Accutorr, Passport) | 0.9 m Cable | Ref. 35230

61,75 €

SpO₂ pulse oximetry sensor of the clip type for adult patient, compatible with Datascope monitors Accusat, Accutorr 3/4 SAT, Accutorr Plus and Passport (SpO₂ module). It incorporates a 0.9 m cable and requires the extension cable Ref. 35301 for connection to the device. Replacement part of quality equivalent to the original, supplied with manual in GB, FR, IT and ES. Sales unit: 1 unit.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35230

Description

1. Commercial Introduction

The adult finger SpO₂ pulse oximetry sensor compatible with Datascope (Ref. 35230) is the reliable replacement your service needs to keep the Datascope family monitors operational: Accusat, Accutorr 3/4 SAT, Accutorr Plus and Passport. It is a consumable of quality equivalent to the original accessory, designed for continuous and non-invasive monitoring of blood oxygen saturation (SpO₂) and pulse rate in adult patients, both on the hospital ward and in emergency, operating theatre and critical care. A practical solution to renew the fleet of sensors at your centre with maximum compatibility and at a very competitive cost per unit.

2. Technical Explanation

Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry: the sensor emits light at two wavelengths through the vascular bed of the finger and detects differential absorption according to the degree of blood oxygenation, also calculating pulse rate. This sensor, of the adult patient finger clip type, connects to the Datascope monitor via a 0.9 m cable; for connection to the device, the extension cable (Ref. 35301) must be used, as indicated by the manufacturer. All products are supplied with instruction manuals in GB, FR, IT and ES.

3. Technical Specifications

Product data

Brand Datascope
Sales unit 1 unit
Device type Medical device
Device class II B
CND C900301
EAN 6900234100283

Technical features

Sensor type Adult patient finger clip (Adult Finger)
Cable length 0.9 m
Extension cable Ref. 35301 (required for connection to the device)
Compatibility Accusat, Accutorr 3/4 SAT, Accutorr Plus, Passport (SpO₂ module)
Manufacturer reference 35230
Documentation Manual in GB, FR, IT, ES

4. Equivalences and Cross-References

This sensor corresponds to the original reference Ref. 35230, compatible with the indicated Datascope monitor family. For its use, the extension cable Ref. 35301 is essential, sold separately, which allows the sensor to be connected to the monitor’s SpO₂ module. There is no manufacturer-validated equivalence table cross-referencing this reference with codes from other brands on a 1:1 interchangeable basis; before replacing the sensor at your centre, always verify the exact make and model of the monitor to confirm compatibility.

5. Selection tips and variants of interest

Confirm the model of your Datascope monitor (Accusat, Accutorr 3/4 SAT, Accutorr Plus or Passport) and order the Ref. 35301 (extension cable) together with the sensor if your installation requires it to achieve connection to the device. For routine maintenance, clean the sensor surface between patients with a soft cloth following the manufacturer’s instructions and store the product in a dry place, protected from direct sunlight and extreme temperatures. For volume orders, supply contracts or needs for other patient populations (paediatric or adult with other cable lengths), consult our technical-commercial team at Cahnos, who will confirm the exact reference and B2B conditions.

Additional information

Manufacturer

GIMA S.p.A.

Manufacturer reference

35230

Sensor type

Adult patient finger clip (Adult Finger)

Cable length

0.9 m

Extension cable required

Ref. 35301

Compatibility

Accusat, Accutorr 3/4 SAT, Accutorr Plus, Passport (SpO₂ module)

CND code

C900301

EAN

6900234100283

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF · Multilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF
📜 CertificatesDichiarazioni Varie PDF