Description
1. Commercial Introduction
The pre-wired disposable ECG electrode FIAB F9058NRM is a highly reliable monitoring consumable, specifically designed for neonatal and paediatric patients. Its 23×30 mm oval foam support, its integrated 50 cm cable and its radiotransparent nature make it the ideal solution for neonatal intensive care units, neonatology services, incubators and neonatal transport, as well as for any area where heart rate needs to be monitored without interfering with imaging tests.
It is supplied in bags of 3 units, with a box of 150 units, adapted to the continuous consumption of hospitals and supply centres. A pre-wired quick-connection format that simplifies nursing routines and reduces failure points compared with conventional electrodes with lead wires.
2. Technical Explanation
This electrode acts as an interface between the neonate’s skin and the bedside monitor: the foam support with medical-grade adhesive ensures a gentle but firm fixation on the delicate skin of the newborn, while the SSC (Ag/AgCl) sensor guarantees stable, low-impedance signal transmission for a clean and continuous ECG trace.
The integrated 50 cm cable ends in a 1.5 mm DIN connection socket (female), compatible with the lead wires of most ECG monitors with European standard. Its radiotransparent condition allows the electrodes to remain in place during X-rays, fluoroscopy and other imaging examinations without generating artefacts or interruptions in monitoring, a critical value when the neonatal patient requires continuous cardiac monitoring during the examination. It is a single-use and latex-free product.
3. Technical Specifications
| Brand | FIAB (FIAB SpA, Vicchio, Florence, Italy) |
| Reference FIAB | F9058NRM |
| Type | Disposable pre-wired ECG electrode |
| Electrode size | 23×30 mm (oval) |
| Support / material | Medical-grade foam |
| Sensor | SSC (Ag/AgCl) |
| Cable | 50 cm, pre-wired |
| Connection | 1.5 mm DIN socket (female) |
| Target population | Neonatal / paediatric |
| Radiotransparency | Yes (radiolucent), suitable for X-ray and imaging tests |
| Use | Single-use (disposable), latex-free |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
Available references
| Reference FIAB | F9058NRM |
| Electrode size | 23×30 mm |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
4. Equivalences and Cross-References
This reference belongs to the category of pre-wired, radiotransparent neonatal monitoring electrodes with 1.5 mm DIN socket. After verifying manufacturer and authorised distribution catalogues, the cited references should be understood as comparable by category (not 1:1 interchangeable): check one by one the support material, patch size, connector type and monitor lead wire before any substitution.
| Manufacturer / Brand | Family / Model | Reference code | Level | Observations |
|---|---|---|---|---|
| FIAB Group | Pre-wired radiotransparent neonatal foam series, oval format 23×30 mm | F9058N/60 (60 cm cable) | Variant of the same family | Same geometry, support and sensor; the cable length varies (60 cm instead of 50 cm). |
| 3M / Solventum (Red Dot™) | Pre-wired radiolucent neonatal electrode 2282, soft cloth 22×22 mm | 2282 / 2282L | Comparable by category | Cloth support versus foam and smaller surface; radiolucent cable with 1.5 mm DIN socket. |
| Cardinal Health (Kendall™) | KittyCat™ Cloth Pre-Wired neonatal radiolucent | 1051NPSM | Comparable by category | Cloth support, ~60 cm cable and safety socket 0.060″ (approx. 1.5 mm DIN); it is not foam. |
| Halbach Medical | Clinical ECG Electrode P22DR (neonatal) | EC849923 | Comparable by category | Ø 22 mm, 60 cm cable, DIN 1.5 mm connector, hydrogel and radiolucent; non-woven cloth support. |
| FIAB Group (4 mm sockets) | Radiolucent neonatal foam series with 4 mm socket | F9053NRM / F9053NRM/80 | Connection variant | Same support and sensor, but 4 mm connector and 35 or 80 cm cable; not interchangeable without an adapter. |
There is no equivalence table validated by the manufacturer that authorises the substitution of original electrodes with third-party patches: the connector, lead wire and patch size are specific to each monitoring platform. Any substitution must be validated against the technical data sheet and instructions for use of the monitor; consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Check the connector type of your monitor: this reference uses a 1.5 mm DIN socket. If your lead wire uses a 4 mm connector, request the variant of the same FIAB family with 4 mm socket (F9053NRM, 35 cm cable, or F9053NRM/80, 80 cm cable).
Cable length: if you need more reach between the patient and the monitor (e.g. in incubators or beds with high rails), the F9058N/60 version with 60 cm cable offers greater manoeuvrability while maintaining the same performance.
Radiotransparency: if the patient may require X-ray or imaging control during monitoring, this version avoids artefacts without removing the electrode. Radiotransparency refers to plain imaging (X-rays); check the equipment manual for compatibility with magnetic resonance imaging.
Single-use and storage: disposable, single-use per patient; store in a dry place and respect the expiry date of the packaging to avoid compromising the conductivity of the adhesive or the quality of the gel.
Institutional orders: the box of 150 units is intended for the supply of neonatology services, neonatal ICU and paediatrics. For tenders and competitions, contact the technical-commercial department of Cahnos to confirm compatibility with your monitor fleet before placing the order.





Reviews