Description
1. Commercial Introduction
The disposable prewired ECG electrode FIAB F9054N3/55 is a monitoring consumable designed specifically for paediatric and neonatal patients. Its non-woven fabric (TNT) backing of 23×30 mm, its SSC sensor (Ag/AgCl) and its integrated 55 cm lead with 4 mm female connector ensure reliable, continuous, low-impedance electrocardiographic recording with minimal impact on the newborn’s delicate skin. It is the ideal solution for paediatric departments, neonatal ICUs, incubators, neonatal transport and any monitoring point where a prewired electrode that is quick to connect and easy to place is required. It is supplied in a pack of 150 units (50 bags of 3 units), suited to the continuous consumption of hospitals and supply centres. Sale on quotation.
2. Technical Explanation
The electrode acts as an interface between the patient’s skin and the bedside monitor: the non-woven fabric (TNT) backing ensures a soft yet firm fixation, adapting to the newborn’s thorax without irritating immature skin, while the SSC sensor (silver/silver chloride, Ag/AgCl) on solid low-impedance gel ensures stable signal transmission for a clean, continuous ECG trace. Being a prewired electrode, the 55 cm lead is integrated into the patch itself, simplifying nursing routine and reducing failure points compared with conventional electrodes that require an additional lead wire. The lead ends in a 4 mm female connector (banana socket), compatible with the patient cables of most ECG monitors and electrocardiographs with a 4 mm connection standard. It is a single-use, latex-free product: it must be disposed of after each patient and the expiry date on the packaging must be respected so as not to compromise the conductivity of the adhesive or the gel.
3. Technical Specifications
Main features of the paediatric/neonatal pre-wired ECG electrode FIAB F9054N3/55:
| Characteristic | Value |
|---|---|
| Reference FIAB | F9054N3/55 |
| Electrode size | 23×30 mm |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
Additional technical data:
| Parameter | Specification |
|---|---|
| Type | Disposable pre-wired ECG electrode |
| Application | Paediatric and neonatal |
| Support material | Non-woven fabric (TNT / non woven) |
| Electrode dimensions | 23×30 mm |
| Sensor | SSC (silver/silver chloride, Ag/AgCl) |
| Cable length | 55 cm, pre-wired |
| Connection | 4 mm female connector (banana socket) |
| Use | Single-use (disposable), latex-free |
| Presentation | Bag of 3 units |
| Minimum sales unit | Box of 150 units (50 bags of 3) |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
4. Equivalences and Cross-References
This reference belongs to the category of prewired paediatric/neonatal monitoring electrodes with 4 mm connection and non-woven backing. The following references share the category (disposable prewired paediatric/neonatal ECG electrode) and have a code confirmed in the manufacturer’s official catalogue or in authorised distribution. Any comparison between brands should be understood as comparable by category (not interchangeable 1:1): check one by one the backing material, dimensions, lead length and connector type before substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| FIAB Group | Pre-wired neonatal radiotransparent foam electrode, oval format 23×30 mm, SSC sensor | F9053NRM / F9053NRM/80 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: 4 mm connector, neonatal use and SSC sensor. Differences: foam backing and radiotransparent compared with the non-woven fabric of this reference, with 80 cm lead; verify backing material and lead length. |
| FIAB Group | Pre-wired radiotransparent neonatal series of non-woven fabric | F9057PRRM / F9057NQ/RM/50 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: SSC sensor, non-woven backing, oval formats 20×15 mm or 23×30 mm. Differences: DIN 1.5 mm connection compared with the 4 mm connector of this reference; verify the monitor lead socket. |
| Ambu (BlueSensor®) | Pre-wired radiolucent neonatal ECG electrode | BRS-50-A | Comparable by category (not interchangeable 1:1) | Code confirmed in the official Ambu data sheet: solid gel, 50 cm prewired lead and 4 mm connector. Differences: extra-small size (16×19 mm) and soft cloth backing compared with the 23×30 mm non-woven fabric format; verify adhesion surface and monitor lead. |
| Lessa (AB Médica) | Radiotransparent carbon neonatal single-use ECG electrode | 9909957 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: TNT (non-woven) backing, 4 mm female connector, oval shape 23×20 mm. Differences: carbon radiotransparent, shorter lead (0.35 m) and presentation of 150 units (5 bags of 30); verify lead length and required radiotransparency. |
There is no equivalence table validated by the manufacturer that authorises the 1:1 replacement of this electrode with third-party patches: the connector, lead wire and patch size are specific to each monitoring platform. Any replacement must be validated against the technical data sheet and instructions for use of the monitor and the electrode; consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Check the connector type on your monitor: this reference F9054N3/55 uses a 4 mm female connector (banana socket). If your lead wire uses a DIN socket of 1.5 mm (1.55 mm), consider the variants of the same FIAB family with that connection (for example, the F9057 series with non-woven backing and DIN socket). The two formats are not interchangeable without an adapter.
Choose the format according to the patient: the 23×30 mm electrode is an intermediate size suitable for paediatric patients and neonates with a larger thoracic surface; for very low birth weight newborns, a smaller surface format within the prewired FIAB range may be considered. The non-woven fabric (TNT) backing offers a soft, breathable adhesion that is very well tolerated on delicate skin, although it is not radiotransparent: if imaging tests (X-ray) are anticipated during monitoring, consult the radiotransparent versions of the family.
Use and storage: single-use, disposable and latex-free electrode; clean and dry the skin before application, avoiding creams or oily residues to optimise contact impedance. Store sealed bags in a dry place, rotate stock on a FIFO basis and respect the expiry date on the packaging so as not to compromise the conductivity of the adhesive or the gel. For volume orders, allocations or tenders, contact the technical-commercial department of Cahnos, indicating the model of your monitor fleet and the connection type of your lead wires.