The pre-wired disposable ECG electrode FIAB Ref. F9057N is a single-use consumable specifically designed for continuous electrocardiographic monitoring of paediatric and neonatal patients. Its non-woven fabric (TNT) support in an oval format of 23×30 mm, combined with a silver/silver chloride (Ag/AgCl, described by the manufacturer as SSC sensor) sensor, provides a stable and reliable signal with very gentle contact on the immature skin of the newborn. The integrated 50 cm lead ends in a 1.5 mm DIN female connector, compatible with the lead wires of most European-standard bedside monitors. It is supplied in a box of 150 units (50 bags of 3 units), a format suited to the continuous consumption of neonatology, paediatrics, ICU and medical transport services. It is a product of the brand FIAB SpA (Vicchio, Florence, Italy), distributed by Cahnos and marketed on quotation.
2. Technical Explanation
The electrode acts as an interface between the patient’s skin and the bedside monitor: it captures the electrical activity of the heart and transmits it with the minimum possible distortion. In the neonatal population, the quality of the recording depends on three key factors: adhesion (the electrode must remain fixed throughout monitoring), low contact impedance (provided by the conductive gel and the Ag/AgCl sensor) and stability against patient movement. The non-woven fabric (TNT) support is light, flexible and breathable: it adapts to the contour of the newborn’s chest and maintains its integrity during continuous monitoring. The SSC sensor (Ag/AgCl) offers a stable contact potential and very low polarisation, reducing motion artefacts. Being a pre-wired electrode, the lead wire is integrated and ends in a 1.5 mm female connector (DIN type), which simplifies the nursing routine and reduces failure points compared with conventional electrodes with a patient cable. It is a single-use, latex-free product that must be disposed of after each patient and stored in its closed packaging in a dry place.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9057N |
| SKU Cahnos | FIAB-F9057N |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Disposable pre-wired surface ECG electrode |
| Population | Paediatric / neonatal |
| Electrode size | 23×30 mm (oval) |
| Support material | Non-woven fabric (TNT / non woven) |
| Sensor | SSC (silver/silver chloride, Ag/AgCl) |
| Cable length | 50 cm (pre-wired) |
| Connection | 1.5 mm female DIN connector |
| Use | Single-use (disposable), latex-free |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
Available references
| Reference | Description |
|---|---|
| FIAB-F9057N | Pre-wired disposable paediatric/neonatal ECG electrode, TNT 23×30 mm, 50 cm lead, SSC sensor, DIN 1.5 mm connection · Box of 150 units |
| F9057N | Official manufacturer reference FIAB (identical product) |
Note: the technical parameters come from the manufacturer’s official catalogue (fiab.it, ECG > Disposable Electrodes > Wire > Paediatric, Non Woven); verify the labelling of the supplied batch before use in tendering.
4. Equivalences and Cross-References
Reference F9057N is a manufacturer-specific code of FIAB SpA within its catalogue of pre-wired paediatric/neonatal electrodes with non-woven support. No equivalence table validated by the manufacturer has been found that authorises the 1:1 substitution of this electrode with third-party patches: the connector, lead length and patch size are specific to each monitoring platform. The following references are identified as comparable by category (pre-wired neonatal electrode with 1.5 mm DIN socket), verified in public sources, and never as interchangeable without field-by-field validation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| 3M / Solventum (Red Dot™) | Pre-wired radiolucent neonatal electrode, soft cloth 22×22 mm | 2282 / 2282L | Comparable by category (not interchangeable 1:1). Fabric support versus TNT; verify connector and lead wire. |
| Cardinal Health (Kendall™) | KittyCat™ Cloth Pre-Wired, neonatal radiolucent | 1051NPSM / 31424743 | Comparable by category (not interchangeable 1:1). 2.5 cm cloth and ~60 cm cable; verify dimensions and backing. |
| Halbach Medical | Clinical ECG Electrode P22DR (neonatal) | EC849923 | Comparable by category (not interchangeable 1:1). Non-woven cloth backing 22 mm, 60 cm cable, DIN 1.5 mm. |
| FIAB Group | Pre-wired non-woven neonatal series (variants of the same family) | F9057PRRM / F9057NRM / F9057NQ/RM/50 / F9057NQ/RM/AAMI | Variants from the same manufacturer (not interchangeable 1:1). Same support and sensor; they differ in radiotransparency, geometry or lead length. |
Any substitution must be validated against the technical data sheet and instructions for use of the monitor and the electrode; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
Check your monitor’s connector: this reference uses a 1.5 mm DIN female connection, the most common European standard on bedside monitors. If your lead wire uses a 4 mm connector (banana type), consider the variants of the same FIAB family with a 4 mm socket, such as the pre-wired foam series F9053N (35 cm lead). They are not interchangeable with each other without an adapter.
Choose the format according to the patient: the oval patch of 23×30 mm with non-woven fabric support is suitable for neonates and low-weight paediatric patients, offering a reduced and breathable adhesion surface. For extremely premature infants, even smaller formats within the FIAB range may be considered (e.g. oval 20×15 mm).
Non-woven support versus foam: TNT is light and breathable, ideal for delicate skin and prolonged monitoring under temperature control; if your protocol prioritises radiotransparency to keep the electrodes in place during X-rays, consult the radiotransparent versions of the same FIAB family (RM series of F9057 and F9058).
Single-use and storage: disposable, single use per patient; clean and dry the skin before application, avoiding creams or oily residues to optimise contact impedance. Keep the bags closed in a dry place, rotate stock on a FIFO basis and respect the expiry date on the packaging, as the conductive gel may lose conductivity if the sachet deteriorates.
Institutional orders: the box of 150 units (50 bags of 3 units) is designed for the supply of neonatology, paediatrics and ICU services. For complete equipment, tenders or bidding processes, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection of your lead wires.