Description
1. Commercial Introduction
The FIAB F9057NRM electrode is a disposable ECG monitoring consumable designed specifically for paediatric and neonatal patients. Its non-woven fabric (TNT) backing of 23×30 mm in an oval format offers gentle and secure adhesion, respectful of the delicate and immature skin of the newborn. Being a pre-wired electrode with an integrated 50 cm lead, it simplifies the nursing routine: it requires no additional lead wire and reduces potential points of failure in the connection. Its radiotransparent nature makes it the usual choice in neonatal intensive care units, neonatology departments and neonatal transport, where continuous monitoring must be maintained during X-rays and other imaging examinations.
2. Technical Explanation
The electrode acts as an interface between the patient’s skin and the bedside monitor. The non-woven fabric backing with medical-grade adhesive ensures a firm yet gentle fixation on the neonate’s skin, while the SSC conductive sensor guarantees stable, low-impedance signal transmission for a clean, continuous ECG trace. The pre-wired 50 cm lead terminates in a female 1.5 mm connection (DIN safety socket, standard DIN 42802), compatible with the lead wires of most ECG monitors with the European standard. Its radiotransparent condition allows the electrodes to remain in place during X-rays, fluoroscopy and other imaging examinations without generating artefacts or interruptions in monitoring, an essential aspect when the neonatal patient requires continuous cardiac control during the examination. It is a single-use product, disposable after each patient; the expiry date on the packaging must be respected to avoid compromising the conductivity of the adhesive or the gel.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9057NRM |
| Electrode size | 23×30 mm (oval shape) |
| Packaging | 150 units (50 bags of 3 units) |
| Units per box (web) | 150 |
| Parameter | Specification |
|---|---|
| Brand | FIAB (FIAB SpA, Vicchio – Florence, Italy) |
| Type | Disposable pre-wired ECG electrode |
| Target population | Paediatric / neonatal |
| Support | Non-woven fabric (TNT / non woven) |
| Sensor | SSC (Ag/AgCl) |
| Cable | 50 cm, pre-wired |
| Connection | Female 1.5 mm DIN (DIN 42802) |
| Radiotransparency | Yes (radiolucent, suitable for X-ray and imaging examinations) |
| Use | Single-use (disposable) |
| Presentation | Bags of 3 units |
Note: radiotransparency is intended for planar imaging (X-rays); consult the equipment manual to verify compatibility with magnetic resonance imaging before use in MRI.
4. Equivalences and Cross-References
This reference belongs to the FIAB family of pre-wired, radiotransparent neonatal monitoring electrodes with non-woven backing. Within the same manufacturer series are the references FIAB F9057PRRM and F9057NQ/RM/50 (as well as the variant F9057NQ/RM/AAMI), which share the SSC sensor, non-woven backing, 1.5 mm DIN socket and radiotransparent nature, differing mainly in geometry (oval 20×15 mm, 23×30 mm or square 22×22 mm) and lead length. Comparable references by category from other manufacturers are also available on the market (e.g. 3M/Solventum Red Dot series 2282, Kendall/KittyCat 1051NPSM or Halbach EC849923), but these should be understood as comparable by application and not interchangeable 1:1: always verify backing material, format, diameter, connector type and monitor lead wire before substitution. Consult the technical department at Cahnos to validate any substitution on your monitoring platform.
5. Selection tips and variants of interest
Check the connector type on your monitor: this reference uses a female 1.5 mm connection (DIN 42802 socket). If your lead wire uses a 4 mm connector, the FIAB family has variants with a 4 mm socket. Choose the format according to the patient’s weight and chest surface: the 23×30 mm non-woven fabric backing offers a reduced adhesion area, ideal for very delicate skin; for very low birth weight neonates or extreme premature infants, smaller oval formats from the same series may be considered. If radiotransparency is not a requirement, standard alternatives from the range can be considered. Store in a dry place, respect the expiry date on the packaging and use each electrode for a single patient. For institutional orders and tenders, contact the technical-commercial department at Cahnos: this product is sold on quotation and in full boxes.