Description
1. Commercial Introduction
The ECG patient cable with inspectable manifold and snap connection from FIAB (Ref. F5224C) is the reliable and robust replacement accessory that your Cardioline electrocardiograph needs to obtain clean and stable electrocardiographic recordings. Manufactured by FIAB S.p.A. (Vicchio, Florence, Italy), one of the European leaders in electrocardiography and cardiac diagnostic accessories, this cable is designed for intensive clinical use in cardiology practices, emergency departments, occupational medicine units, diagnostic centres and hospitalisation.
Thanks to its inspectable manifold design, the technical service can check the condition of the connections without disassembling the assembly, which simplifies preventive maintenance and reduces signal losses due to deterioration in the lead bifurcation area. It is the right choice for renewing your equipment’s cable or expanding your stock with guarantees of durability and signal quality.
2. Technical explanation of the equipment
The ECG patient cable is the element in the recording chain that transmits the electrocardiographic signal captured by the electrodes (chest and limb) to the input of the electrocardiograph. Stable, interference-free transmission depends directly on the quality of the cable, the insulation of its conductors and the integrity of its connections.
This reference incorporates an inspectable manifold, i.e. the piece where the individual leads converge is designed to be opened and checked easily, allowing signs of wear, moisture or false contacts to be detected before they compromise the trace. The termination at the electrodes is of the snap type (press stud, called CLIP by the manufacturer), the most common standard for disposable and reusable ECG electrodes, ensuring a fast, firm and reproducible coupling on each use.
Proper cable maintenance is essential in clinical environments: periodically checking the insulation, connections and the manifold area prevents artefacts, signal loss and repeat tests, ensuring a reliable diagnostic recording.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F5224C |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Cardioline |
Product technical data
| Parameter | Value |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB S.p.A. (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Distributor | Inspectable (openable manifold for connection checks) |
| Electrode connection | Snap (press stud / CLIP) |
| Compatibility | Devices Cardioline |
| Presentation | 1 unit (sold in full boxes) |
| Classification in FIAB catalogue | ECG > Patient Cables > Inspectable Manifold > Snap |
| Sales unit | On quotation (no list price) |
4. Equivalences and Cross-References
Reference F5224C is confirmed in the manufacturer’s official catalogue (FIAB, Italy) as an ECG patient cable with inspectable manifold and snap connection for Cardioline devices. There is no 1:1 equivalence table validated by the manufacturer that cross-references this code with third-party codes interchangeably: as this is a specific accessory for the Cardioline platform, any replacement with a cable from another manufacturer must always be validated against the technical data sheet and the electrocardiograph’s instructions for use (number of leads, equipment connector type and electrode termination).
In the Cahnos catalogue you can find ECG patient cables for Cardioline equipment and electrocardiography environments, comparable by category (not interchangeable 1:1 without technical verification):
| Manufacturer / Brand | Product | Reference / SKU | Level |
|---|---|---|---|
| Cardioline | 12-lead ECG cable for electrocardiographs 54200-54205 (replacement) | 54210 (GM54210) | Comparable by category (not interchangeable 1:1) |
| GIMA | Universal 10-lead ECG cable (compatible with Cardioline, Bionet, Schiller and more) | 33328 (GM33328) | Comparable by category (not interchangeable 1:1) |
| GIMA | 10-lead ECG patient cable, snap connection, compatible with Cardioline | GM54007 | Comparable by category (not interchangeable 1:1) |
| GIMA | 10-lead ECG patient cable, banana connection, compatible with Cardioline | GM54006 | Comparable by category (not interchangeable 1:1) |
No substitution should be applied without first verifying the number of leads, the electrocardiograph connector and the electrode terminal type. Consult the technical-commercial department of Cahnos before proposing alternatives in tenders.
5. Selection tips and variants of interest
Before placing the order, confirm the exact model of your Cardioline electrocardiograph and the terminal type used on the electrodes: this product has a snap (press stud) connection, so it must be used with disposable electrodes or forceps with a snap socket. If your equipment fleet uses 4 mm banana terminals, consult the cable variants in the same category available at Cahnos.
Take advantage of the inspectable manifold: include checking the bifurcation area in periodic maintenance, along with visual inspection of the insulation and the condition of the connectors, especially before diagnostic tests that require maximum reliability. It is recommended to have a spare cable per electrocardiograph so as not to interrupt clinical activity during maintenance.
To complete the service provision, combine this cable with disposable snap-connection electrodes, limb forceps, chest suction electrodes and connection adapters available in the Cahnos catalogue. For volume orders, fleets or tenders, contact our technical-commercial department to confirm exact compatibility with your equipment fleet and obtain a formalised quotation under B2B conditions.