Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with the ECG patient cable FIAB Ref. F5778RC, a replacement accessory of proven quality manufactured by FIAB SpA (Vicchio, Florence, Italy), one of Europe’s leading specialists in cables and connectivity for electrocardiography. Designed specifically for Schiller equipment, this cable provides stable and reliable signal transmission in daily clinical practice in cardiology departments, emergency services, primary care and functional diagnostic centres. As this is a product supplied on quotation, our technical-commercial team will confirm the exact compatibility with your equipment and the supply conditions.
2. Technical Explanation
The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal picked up by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. The quality of the trace depends directly on the condition of the cable: deteriorated insulation, a loose connector or a fatigued flex point are sources of artefacts, interference and signal loss that can compromise the diagnosis.
This model incorporates an inspectable manifold: the housing that groups the leads can be opened to visually check the condition of the internal connections, conductors and insulation, allowing signs of wear or false contacts to be detected before they affect the quality of the recording. This construction facilitates effective preventive maintenance and extends the service life of the assembly. The patient end has snap-type terminals (press stud, called CLIP by the manufacturer), the most common press-fit attachment system in electrocardiography, which attaches quickly and securely to standard disposable ECG electrodes.
3. Technical Specifications
Specifications verified in the manufacturer’s official catalogue (fiab.it):
| Characteristic | Value |
|---|---|
| Reference FIAB | F5778RC |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Schiller |
Additional catalogue data:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Manifold / connector | Inspectable (openable manifold) |
| Patient connection | Snap / press stud (CLIP) |
| Catalogue category FIAB | ECG > Patient Cables > Inspectable Manifold > Snap |
| Presentation | 1 unit |
| Sales unit | On request (sold in complete boxes, per tariff) |
Available references:
| Reference | Description |
|---|---|
| FIAB-F5778RC | SKU Cahnos / order reference for this product |
| F5778RC | Manufacturer reference FIAB for the same cable |
4. Equivalences and Cross-References
Reference F5778RC is the original factory code FIAB for this ECG patient cable with inspectable manifold and snap connection compatible with Schiller devices, also registered under the distribution SKU Cahnos FIAB-F5778RC: both designations identify the same product unit.
No reliable sources have been found providing an official equivalence table authorising 1:1 replacement with cables from other manufacturers: ECG patient cables are accessories specific to the connector on the equipment side, the number of leads and the electrode attachment system, so any alternative must always be validated against the technical data sheet of the Schiller electrocardiograph. Within the FIAB catalogue itself (verified source fiab.it) there are other references in the same family with inspectable manifold and snap connection for different platforms: F5725RC (Schiller, Esaote, Kontron and Edan), F5726RC (Cardioline, Innomoed, Progetti, Cardiorapid, Cardiotek, Dr. Lee, Nihon-Kohden, Elettronica Trentina/Cardiette and Schiller), F5748RC (Burdick/Quinton and Siemens) or F5738RC (Kenz), among others. Consult the technical department of Cahnos before considering alternatives in tenders.
5. Selection tips and variants of interest
Before placing the order, confirm that your electrocardiograph or monitor corresponds to the Schiller brand and check the terminal type of your electrodes: this reference is fitted with a snap connection (press stud / CLIP), suitable for the press-fit disposable ECG electrodes commonly available on the market. If your electrode stock uses 4 mm plugs or forceps, consider the variants in the same FIAB family with identical equipment compatibility and a different termination, subject to technical validation.
Take advantage of the inspectable manifold by carrying out periodic checks of the condition of the internal connections, the snap terminals and the cable insulation, especially before diagnostic tests or prolonged recordings. It is recommended to keep a spare cable per electrocardiograph so as not to interrupt clinical activity during maintenance, and to replace the assembly at any sign of deterioration or loss of signal quality. For hospital supplies, equipment fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility with your equipment base and request a tailored quote.