Description
1. Commercial Introduction
This replacement ECG cable is the original spare part in the range (reference 33317) designed for the vital signs monitor Ref. 33316. Designed as a replacement item (spare), it allows the patient cable on your device to be replaced quickly and easily and keeps cardiac monitoring running without interruption. It is the recommended maintenance solution for hospitals, emergency departments, intensive care units, cardiology clinics and diagnostic centres that want to always have an operational spare cable for their monitors.
2. Technical explanation of the equipment
The ECG patient cable is the element in the recording chain that connects the electrodes placed on the patient’s chest to the input of the vital signs monitor or the electrocardiograph. It transmits the electrocardiographic signal captured by the electrodes to the device, where it is processed and displayed for clinical analysis. As a reusable accessory subject to mechanical stress and continuous handling on every shift, having an original replacement ensures signal stability, reduces the risk of artefacts and avoids equipment downtime.
3. Technical specifications and tables
Data verified against the manufacturer’s catalogue (Product_DB, reference 33317):
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 33317 |
| Product type | Patient cable for electrocardiography (ECG) – replacement |
| Compatible equipment | Vital signs monitor Ref. 33316 |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | I |
| CND | Z1203020280 |
| EAN | 6945040107569 |
Available references
| Reference | Description |
|---|---|
| 33317 | Replacement ECG cable for vital signs monitor Ref. 33316 (this product) |
4. Equivalences and Cross-References
Reference 33317 corresponds to the official factory code for the replacement ECG cable for monitor 33316, according to the Product_DB catalogue. There is no manufacturer-validated equivalence table cross-referencing this reference 1:1 with codes from other manufacturers. Always check the connector type, the number of leads and the cable configuration of your device before replacing it. In the Cahnos catalogue you will find other cables in the same family, such as the 5-lead ECG cable for the PC-3000, UP-7000 and VITAL lines (Ref. 35137), the universal 10-lead cable (Ref. 33328) or the 3-lead cable, 3-pin version, for Palmare ECG (Ref. 33248); each one is designed for specific equipment and they are not interchangeable with one another without prior technical verification.
5. Selection tips and variants of interest
Before replacing the cable, confirm that your device corresponds to the vital signs monitor Ref. 33316 and that the connector type matches that of this reference; if you have any doubt about compatibility, contact the technical-commercial department at Cahnos stating the exact model of your monitor. Periodically check the condition of the terminals, the integrity of the insulation and the connection area to the device, and clean the cable according to the manufacturer’s instructions for use to maintain a stable signal transmission. It is recommended to keep a spare cable per monitor so that monitoring is not interrupted during maintenance. For volume orders, fleet orders or tenders, request a tailored quote through Cahnos.