We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Replacement ECG cable for vital signs monitor Ref. 33316 – Original replacement (Ref. 33317)

64,60 €

Original replacement electrocardiography (ECG) cable, reference 33317, designed specifically as a replacement part (spare) for the vital signs monitor Ref. 33316. It replaces the device’s patient cable, ensuring stable and reliable electrocardiographic signal transmission during continuous monitoring, without the need for adapters or modifications. It is the ideal maintenance accessory for emergency departments, ICUs, cardiology clinics, hospital wards and diagnostic centres that need a spare cable ready to use and avoid monitor downtime. Class I medical device, sales unit 1 pc. For large orders you can request a quote: contact the technical-commercial department at Cahnos for terms and availability.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33317

Description

1. Commercial Introduction

This replacement ECG cable is the original spare part in the range (reference 33317) designed for the vital signs monitor Ref. 33316. Designed as a replacement item (spare), it allows the patient cable on your device to be replaced quickly and easily and keeps cardiac monitoring running without interruption. It is the recommended maintenance solution for hospitals, emergency departments, intensive care units, cardiology clinics and diagnostic centres that want to always have an operational spare cable for their monitors.

2. Technical explanation of the equipment

The ECG patient cable is the element in the recording chain that connects the electrodes placed on the patient’s chest to the input of the vital signs monitor or the electrocardiograph. It transmits the electrocardiographic signal captured by the electrodes to the device, where it is processed and displayed for clinical analysis. As a reusable accessory subject to mechanical stress and continuous handling on every shift, having an original replacement ensures signal stability, reduces the risk of artefacts and avoids equipment downtime.

3. Technical specifications and tables

Data verified against the manufacturer’s catalogue (Product_DB, reference 33317):

Parameter Specification
Manufacturer GIMA
Manufacturer reference 33317
Product type Patient cable for electrocardiography (ECG) – replacement
Compatible equipment Vital signs monitor Ref. 33316
Sales unit 1 pc
Device type Medical device (medical device)
Device class I
CND Z1203020280
EAN 6945040107569

Available references

Reference Description
33317 Replacement ECG cable for vital signs monitor Ref. 33316 (this product)

4. Equivalences and Cross-References

Reference 33317 corresponds to the official factory code for the replacement ECG cable for monitor 33316, according to the Product_DB catalogue. There is no manufacturer-validated equivalence table cross-referencing this reference 1:1 with codes from other manufacturers. Always check the connector type, the number of leads and the cable configuration of your device before replacing it. In the Cahnos catalogue you will find other cables in the same family, such as the 5-lead ECG cable for the PC-3000, UP-7000 and VITAL lines (Ref. 35137), the universal 10-lead cable (Ref. 33328) or the 3-lead cable, 3-pin version, for Palmare ECG (Ref. 33248); each one is designed for specific equipment and they are not interchangeable with one another without prior technical verification.

5. Selection tips and variants of interest

Before replacing the cable, confirm that your device corresponds to the vital signs monitor Ref. 33316 and that the connector type matches that of this reference; if you have any doubt about compatibility, contact the technical-commercial department at Cahnos stating the exact model of your monitor. Periodically check the condition of the terminals, the integrity of the insulation and the connection area to the device, and clean the cable according to the manufacturer’s instructions for use to maintain a stable signal transmission. It is recommended to keep a spare cable per monitor so that monitoring is not interrupted during maintenance. For volume orders, fleet orders or tenders, request a tailored quote through Cahnos.

Additional information

Manufacturer reference

33317

Product type

Patient cable for electrocardiography (ECG) – replacement

Compatibility

Vital signs monitor ref. 33316

CND code

Z1203020280

EAN

6945040107569

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Replacement ECG cable for vital signs monitor Ref. 33316 – Original replacement (Ref. 33317)”

Your email address will not be published. Required fields are marked *