1. Commercial Introduction
Keep the electrocardiographic recording of your Bosch, Picker, Cambridge and Nihon-Kohden equipment fully operational with this ECG patient cable from FIAB (Ref. F6736P). It is a reusable electrocardiography accessory, manufactured by FIAB SpA (Vicchio, Florence, Italy), a European leader in clinical connectivity and diagnostic accessories. Its design with an inspectable manifold makes it the recommended choice for cardiology clinics, emergency departments, monitoring units and diagnostic centres looking to reduce material turnover, facilitate maintenance and guarantee a quality signal in every recording.
2. Technical explanation of the procedure
The ECG patient cable is the element that transmits the cardiac electrical signal captured by the electrodes placed on the patient’s chest and limbs to the ECG module of the electrocardiograph or monitor. The signal chain comprises the electrode (adhesive, suction or forceps), the individual lead, the yoke or manifold and the equipment connector.
In this model, the inspectable manifold adds a differential value: its body can be opened to access the connection points of the leads, allowing you to check the condition of the contacts, clean them or replace degraded individual leads without discarding the entire assembly. The cable end features a pinch-type connection (PINCH), ideal for attaching to tab (TAB) or button electrodes, ensuring a firm mechanical union and stable contact impedance throughout the recording. Its compatibility is verified by the manufacturer for Bosch, Picker, Cambridge and Nihon-Kohden equipment.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F6736P |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Product data
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Manufacturer reference | F6736P (SKU Cahnos: FIAB-F6736P) |
| Product type | Patient cable for electrocardiography (ECG) |
| Distributor | Inspectable (inspectable manifold) |
| Connection type | Forceps (PINCH) |
| Compatible equipment | Bosch, Picker, Cambridge, Nihon-Kohden |
| Manufacturer category | ECG | Patient Cables | Inspectable Manifold | Pinch |
| Classification | Reusable electrocardiography accessory |
| Sales unit | 1 unit |
4. Equivalences and Cross-References
This product corresponds to the factory reference F6736P from FIAB, verified in the manufacturer’s catalogue (fiab.it) within the ECG family > Patient Cables > Inspectable Manifold > Pinch. No official tables have been found in reliable sources cross-referencing this reference with codes from other manufacturers for a 1:1 replacement: ECG patient cables are specific accessories by connector type, number of leads and equipment platform, so any alternative from another brand must be validated field by field (equipment connector, terminal type, length and number of leads). The declared compatibility is limited to the Bosch, Picker, Cambridge and Nihon-Kohden equipment indicated by the catalogue itself. In the Cahnos catalogue you will find other ECG patient cables from different families (for example, the universal 10- and 12-lead references from the GIMA range), which share the category but are not interchangeable with this model without prior technical verification of the connector and the target equipment.
5. Selection tips and variants of interest
Confirm the exact model of your electrocardiograph or monitor before placing the order: this cable is intended for Bosch, Picker, Cambridge and Nihon-Kohden equipment with a compatible socket. Also check the terminal of your electrodes: the pinch connection (PINCH) is designed for tab or button electrodes; if your practice uses disposable electrodes with a snap or a 4 mm banana terminal, contact our technical department for suitable alternatives and adapters for your cable fleet.
Take advantage of the inspectable manifold to incorporate a preventive maintenance plan: periodically check the connection point of each lead, clean the contacts according to the manufacturer’s instructions and replace only the deteriorated lead instead of renewing the entire cable. It is recommended to have a spare unit per electrocardiograph to avoid interrupting clinical activity during maintenance tasks. As this product is marketed on a quotation basis, for institutional supplies, mixed equipment fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility and supply conditions.