ECG patient cable with inspectable manifold and forceps connection for Burdick/Quinton and Siemens electrocardiographs · FIAB · Ref. F6748RP

Price on request

Patient cable for electrocardiography with inspectable manifold and forceps (PINCH) termination, manufactured by FIAB SpA (Vicchio, Florence, Italy). Compatible with electrocardiographs and monitoring equipment from the Burdick/Quinton and Siemens brands. Its manifold with openable cover allows the condition of the internal connections and insulation to be checked visually, facilitating preventive maintenance and extending the service life of the accessory. Original manufacturer reference: F6748RP (SKU FIAB-F6748RP). Presentation: 1 unit. Product supplied on quotation: contact our technical-commercial department to confirm exact compatibility with your equipment and supply conditions.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F6748RP
Brand
FIAB

Description

1. Commercial Introduction

Renew or complete the wiring of your electrocardiograph with the ECG patient cable from FIAB (Ref. F6748RP), a replacement accessory of proven quality manufactured by FIAB SpA (Vicchio, Florence, Italy), one of Europe’s leading specialists in cabling and connectivity for electrocardiography. Designed specifically for equipment compatible with Burdick/Quinton and Siemens systems, this cable provides stable and reliable signal transmission in daily clinical practice in cardiology departments, emergency departments, primary care and functional diagnostic centres. Its inspectable manifold is a key advantage: it allows the condition of the internal connections to be checked visually, facilitating preventive maintenance and extending the service life of the accessory. As this product is sold on quotation, our technical-commercial team will confirm the exact compatibility with your equipment model and the supply conditions.

2. Technical Explanation

The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal picked up by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. The quality of the trace depends directly on the condition of the cable: deteriorated insulation, a loose connector or a fatigued flex point are sources of artefacts, interference and signal loss that can compromise the diagnosis.

This model incorporates an inspectable manifold: the housing that groups the leads can be opened to visually check the condition of the internal connections, conductors and insulation, allowing signs of wear or intermittent contacts to be detected before they affect the quality of the recording. The patient end is fitted with forceps-type terminals (referred to as PINCH by the manufacturer), the usual attachment system for reusable ECG electrodes, which ensures quick coupling, stable electrical contact and easy handling during patient preparation. The specific connector at the opposite end couples to the patient port of Burdick/Quinton and Siemens devices, ensuring a firm fit and clean traces with minimal interference.

3. Technical Specifications

Specifications verified in the manufacturer’s official catalogue (fiab.it):

Characteristic Value
Reference FIAB F6748RP
Packaging 1 unit
Units per box (web) 1

Additional catalogue data:

Parameter Specification
Brand FIAB
Original manufacturer FIAB SpA (Vicchio, Florence, Italy)
Product type Patient cable for electrocardiography (ECG)
Manifold / central connector Inspectable (openable manifold)
Patient connection Forceps (PINCH / pinzetta)
Compatibility Burdick/Quinton and Siemens
Catalogue category FIAB ECG > Patient Cables > Inspectable Manifold > Pinch
Presentation 1 unit
Sales unit On request (sold in complete boxes, per tariff)

Available references:

Reference Description
FIAB-F6748RP SKU Cahnos / order reference for this product
F6748RP Manufacturer reference FIAB for the same cable

Technical data according to the manufacturer’s official catalogue FIAB. Measurements, models and references are copied verbatim; unconfirmed specifications are not included.

4. Equivalences and Cross-References

Reference F6748RP is the original factory code from FIAB for this ECG patient cable with inspectable manifold and forceps connection compatible with Burdick/Quinton and Siemens devices, also registered under the distribution SKU Cahnos FIAB-F6748RP: both designations identify the same product unit.

No official equivalence table authorising 1:1 replacement with cables from other manufacturers has been found in reliable sources: ECG patient cables are accessories specific to the connector on the equipment side, the number of leads and the electrode attachment system, so any alternative must always be validated against the technical data sheet of the electrocardiograph or monitor.

Reference FIAB Electrode connection Compatibility Level
F6748RP Forceps (PINCH) Burdick/Quinton, Siemens Product reference
F6749RP Forceps (PINCH) Burdick/Quinton, Siemens Family variant – verify fit
F6748R 4 mm plug (PLUG) Burdick/Quinton, Siemens Terminal variant – not interchangeable 1:1
F6749R 4 mm plug (PLUG) Burdick/Quinton, Siemens Terminal variant – not interchangeable 1:1
F5748RC / F5749RC Snap (clip) Burdick/Quinton, Siemens Terminal variant – not interchangeable 1:1
F6778RP Forceps (PINCH) Schiller Comparable by category – not interchangeable 1:1
F6738RP Forceps (PINCH) Kenz Comparable by category – not interchangeable 1:1

These references share a platform or product family but may differ in connector or terminal configuration, so they should not be considered automatically interchangeable. Consult the technical department at Cahnos before proposing alternatives in tenders.

5. Selection tips and variants of interest

Before placing the order, confirm the exact model of your electrocardiograph or monitor and that it corresponds to the Burdick/Quinton or Siemens brands, as well as the attachment system of your electrodes: this reference is fitted with a forceps connection, designed for reusable ECG electrodes with forceps attachment. If your electrode fleet uses 4 mm (banana) plugs or snap fasteners, consider the FIAB variants on the same platform (F6748R or F6749R for 4 mm plug, F5748RC / F5749RC for snap), subject to technical validation.

Take advantage of the inspectable manifold by carrying out periodic checks of the condition of the internal connections, the forceps terminals and the cable insulation, especially before diagnostic tests or prolonged recordings. It is recommended to keep a spare cable for each electrocardiograph so as not to interrupt clinical activity during maintenance, and to replace the whole assembly at any sign of deterioration or loss of signal quality. For hospital supplies, equipment fleets or tenders, contact the technical-commercial department at Cahnos to confirm exact compatibility with your equipment fleet and request a tailored quote.

Additional information

Brand

FIAB

Packaging

1 unit

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Manufacturer reference

F6748RP

Product type

Patient cable for electrocardiography (ECG)

Connection type

Forceps (PINCH)

Compatibility

Burdick/Quinton, Siemens

Presentacion

Unit