Description
1. Commercial Introduction
The ECG patient cable FIAB F6747 is the reference connection accessory for keeping your Fukuda Denshi electrocardiographs and monitors operational. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European specialist in electrocardiography accessories, it incorporates an inspectable manifold that facilitates visual verification of connections and maintenance tasks. With a 4 mm connection plug for the electrodes, this cable is the ideal choice for cardiology practices, monitoring services and diagnostic units that need to replenish or expand their stock of patient cables with guarantees of signal quality and durability.
2. Technical Explanation
The patient cable acts as the transmission path between the electrical signal captured at the electrodes and the recording equipment. In this reference, the signal travels through the unipolar leads to converge in an inspectable manifold (inspectable manifold): a central connection box with an openable cover that groups the lines, protects the junctions and allows easy checking or replacement of connection points without disassembling the assembly. At the end of each lead, a 4 mm plug (connector) is fitted, the standard coupling for limb forceps, chest suction electrodes and tab electrodes in ECG equipment. The opposite, specific connector couples to the patient port of Fukuda Denshi devices, ensuring a firm fit, stable contact impedance and clean traces, with minimal interference and a long service life thanks to periodic inspection and maintenance of the manifold.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F6747 |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Fukuda Denshi |
| Specification | Technical data |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Distributor | Inspectable (inspectable manifold) |
| Electrode connection | 4 mm plug (socket) |
| Equipment connection | Specific connector for Fukuda Denshi devices |
| Application | Resting electrocardiography and monitoring |
| Catalogue category FIAB | ECG > Patient cables > Inspectable manifold > 4 mm plug |
| Presentation | 1 unit |
Technical data according to the manufacturer’s official catalogue FIAB. Measurements and references are reproduced verbatim; unconfirmed specifications are not included.
4. Equivalences and Cross-References
Reference F6747 corresponds to the official factory code of FIAB. Within the FIAB family itself for Fukuda Denshi, related references are identified by equipment platform and by electrode connection system. Any cross-reference with third-party codes (non-FIAB) must be validated against the technical data sheet of the original manufacturer of the cable and the equipment before any possible replacement.
| Reference FIAB | Electrode connection | Compatibility | Level |
|---|---|---|---|
| F6747 | 4 mm plug | Fukuda Denshi | Product reference |
| F6747R | 4 mm plug (R variant) | Fukuda Denshi | Family equivalent (verify fit) |
| F6252 | 4 mm plug | Fukuda Denshi | Comparable by category – not interchangeable 1:1 |
| F6747P / F6747RP | Pinch-type clamp | Fukuda Denshi | Terminal variant – not interchangeable |
| F5252C / F5747C / F5747RC | Snap | Fukuda Denshi | Terminal variant – not interchangeable |
There is no equivalence table validated by the manufacturer that authorises 1:1 replacement with cables from other brands. Before any substitution in a tender, verify the equipment connector type, lead configuration and electrode connection system with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Check the terminal of your electrodes: this reference uses a 4 mm plug (connector), the standard for chest suction electrodes, limb forceps and tab electrodes. If your practice uses snap electrodes or pinch-type forceps, consider the FIAB variants of the same Fukuda Denshi platform (F5252C/F5747C or F6747P/F6747RP series) or the corresponding connection adapters.
Confirm your equipment model: although the reference is intended for Fukuda Denshi devices, the pin layout and connector assembly may vary depending on the platform. Consult our technical department for the exact fit with your electrocardiograph or monitor before placing the order.
Maintenance of the inspectable manifold: take advantage of the manifold’s openable cover to periodically check the condition of the contacts and the continuity of the leads, thereby extending the cable’s service life and signal quality.
Institutional purchases: product without a reference price, sold on quotation. For complete sets, tenders or continuous supply contracts, contact the technical-commercial department of Cahnos indicating the model of your Fukuda Denshi fleet and the type of electrode connection used.