ECG patient cable with inspectable distributor and snap connection for Cardiorapid · FIAB Ref. F6226C

Price on request

Patient cable for electrocardiography with inspectable distributor (manifold) and snap (clip) connection terminals, manufactured by FIAB SpA (Vicchio, Florence, Italy). Reference F6226C, specifically designed for Cardiorapid equipment, guarantees stable and secure electrocardiographic signal transmission. Its openable distributor box allows the internal contacts to be inspected and cleaned without replacing the whole set, extending the useful life of the accessory. Presentation: 1 unit per pack. Product sold on quotation: contact our technical-commercial department at Cahnos to confirm exact compatibility with your electrocardiograph and supply conditions.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F6226C
Brand
FIAB

Description

1. Commercial Introduction

At Cahnos we offer you the patient cable for electrocardiography FIAB Ref. F6226C, an accessory of proven quality with an inspectable distributor and snap connection, specifically designed for equipment of the brand Cardiorapid. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European reference in medical electronics accessories, this cable allows you to maintain the diagnostic quality of your electrocardiograph with a robust, reliable and easy-to-maintain replacement. It is the ideal solution for cardiology practices, emergency departments, primary care centres and functional diagnostic units that work with Cardiorapid equipment.

2. Technical Explanation

The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal captured by the electrodes to the electrocardiograph. The signal travels the following path: electrode (adhesive, suction cup or forceps) → individual lead → cable distributor or manifold → equipment connector.

This model incorporates an inspectable distributor (inspectable manifold): a connection box that can be opened to inspect and clean the internal contacts without having to replace the entire cable, which facilitates preventive maintenance and extends the useful life of the accessory. The patient-end terminals are of the snap (clip) type, the most common connection system in disposable ECG electrodes: each clip attaches quickly and securely to the electrode button, ensuring firm mechanical contact and stable contact impedance during recording.

3. Technical Specifications

The manufacturer’s catalogue specifications are detailed below:

Characteristic Value
Reference FIAB F6226C
Packaging 1 unit
Units per box (web) 1
Compatible with Cardiorapid

Additional data identified in the FIAB catalogue:

Parameter Specification
Brand FIAB
Original manufacturer FIAB SpA (Vicchio, Florence, Italy)
Product type ECG patient cable (ECG patient cable)
Distributor type Manifold / inspectable distributor box (inspectable manifold)
Patient connection Snap / clip (CLIP)
Compatibility Cardiorapid
Catalogue category ECG > Patient Cables > Inspectable Manifold > Snap
Presentation 1 piece per pack

4. Equivalences and Cross-References

This product corresponds to the factory reference F6226C from FIAB SpA (marketed by Cahnos under the SKU FIAB-F6226C). The declared compatibility with Cardiorapid equipment comes from the manufacturer’s official catalogue.

No official equivalence table has been found in reliable sources that would allow this F6226C reference to be replaced 1:1 by cables from other manufacturers. ECG patient cables are accessories specific to the connector of each electrocardiograph, so the number of conductors, the type of terminal (snap) and the equipment-side connector must always be verified against the electrocardiograph’s technical data sheet before adopting an alternative. Within the same FIAB family of inspectable distributor, the following variants can be consulted according to connection type and compatibility:

Reference FIAB Connection Compatibility
F6226C Snap Cardiorapid
F6226 4 mm plug Cardiorapid, Aspel, Bionet
F6226P Forceps (PINCH) Cardiorapid, Aspel, Bionet
F5226C Snap Cardiorapid, Aspel, Bionet

Always consult our technical-commercial department before fixing references in specifications or tenders.

5. Selection tips and variants of interest

First confirm the exact model of your electrocardiograph: this F6226C reference is indicated for the Cardiorapid equipment declared by the manufacturer. Verify the type of terminal at the patient end: the snap (clip) connection is compatible with standard button disposable ECG electrodes, and is not interchangeable with forceps or pin systems, so you must choose the variant according to your electrode park and the equipment connector.

It is recommended to have a spare cable per workstation to avoid interrupting diagnostic activity during cleaning, maintenance or replacement of the wiring. Take advantage of the inspectable distributor: periodically inspect and clean the internal contacts according to the manufacturer’s instructions for use, and replace the part at any sign of deterioration, loss of signal quality or insulation breakage.

For hospital supplies, mixed fleets or tenders, contact the technical-commercial team at Cahnos to confirm exact compatibility with your equipment and obtain a formalised quotation without obligation.

Additional information

Brand

FIAB

Packaging

1 unit

Compatibility

Cardiorapid

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Manufacturer reference

F6226C

Product type

Reusable ECG patient cable

Distributor type

Inspectable (inspectable manifold)

Patient connection

Snap / clip (CLIP)

Presentation

1 unit per pack

Units per box