Description
1. Product Presentation
Complete or renew the monitoring wiring of your equipment with this 7-lead ECG patient cable with button adapters (reference MEC31.90-9460), manufactured by Beneware and distributed through medical ECONET GmbH. It is the recommended spare part for the CT-08 patient monitor from APK Technology, designed to preserve the quality of electrocardiographic recording in consultations, emergency departments, hospitalisation and continuous bedside monitoring. As this is a product sold on quotation, our technical-commercial team will confirm the exact compatibility with your equipment and the supply conditions.
2. Technical Explanation
The patient cable is the element of the recording chain that connects the electrodes placed on the patient’s chest and limbs to the monitor input, transmitting the heart’s electrical signal with minimal loss and interference. This model has 7 conductors (7-wire), a wide lead configuration that allows a greater number of ECG channels to be captured simultaneously, facilitating the detection of arrhythmias and rhythm disturbances with greater precision than 3- or 5-lead systems.
The button adapters (Druckknopfadapter) located at the patient end offer a snap-type pressure connection system: fast, secure and convenient, as they attach directly onto disposable electrodes with a standard button terminal. Their robust construction and the specific connector for the CT-08 environment ensure easy assembly and stable signal transmission, minimising artefacts and false alarms during continuous monitoring.
3. Technical Specifications
| Characteristic | Specification |
| Brand / manufacturer | Beneware |
| Original distributor | medical ECONET GmbH |
| Product type | ECG patient cable (EKG Patientenkabel) |
| Number of conductors | 7 wires (7-wire) |
| Patient connection | Pressure/snap button adapters (Druckknopfadapter) |
| Compatible equipment | Patient monitor CT-08 (APK Technology) |
| ECONET category | EKG | Langzeit-EKG | Zubehör (monitoring accessory) |
| Use | Reusable; spare or additional cable |
Available references
| Reference | Description |
| MEC31.90-9460 | SKU Cahnos / order reference of the 7-lead ECG cable with button adapters |
| 31.90-9460 | Article number medical ECONET / manufacturer reference of the same cable |
Technical data according to the manufacturer’s catalogue (medical ECONET GmbH).
4. Equivalences and Cross-References
This cable corresponds to references MEC31.90-9460 (SKU Cahnos) and 31.90-9460 (article number medical ECONET), which identify the same product unit from Beneware distributed via medical ECONET GmbH.
No official equivalence table has been found in reliable sources that would allow this reference to be substituted 1:1 with cables from other manufacturers: ECG patient cables are accessories specific to each monitor’s connector, so the number of conductors, the terminal type (button) and the equipment-side connector must always be verified against the technical data sheet of the CT-08 monitor before adopting an alternative.
5. Selection tips and variants of interest
First confirm the exact model of your monitor: this reference is intended for the CT-08 equipment. Verify the number of conductors required by your equipment (7 in this case) and the terminal type at the patient end: the button adapters are compatible with the disposable ECG electrodes with snap/pressure connection commonly available on the market and are not interchangeable with forceps systems (Klammer).
Within the same family of ECG cables distributed by medical ECONET you will find complementary variants from the Cahnos catalogue for other equipment in the APK Technology range: 3-lead cables with button adapters for the PalmCare Duo and M850 monitors (ref. MEC41.13-5357), a 5-lead version with button for PalmCare Duo and M850 (ref. MEC41.13-5359), 3-lead cables with button for the M800 monitor (ref. MEC41.13-5344) and 3-lead cables with button for the M20 and SMART 9 monitors (ref. MEC41.13-5346). It is recommended to have a spare cable per workstation and to periodically inspect the condition of the adapters, connectors and insulation. For volume orders, equipment sets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility and obtain a formal quotation without obligation.