1. Introduction
The banana-to-crocodile clip (alligator) adapter, factory reference 33376, is the essential connection accessory for resolving compatibility between patient cables with a 4 mm banana terminal and tab or tongue electrodes (TAB). Its design, with a universal 3–4 mm banana female socket at one end and a crocodile clip at the other, allows the cables of electrocardiographs, monitors and neurophysiology equipment to be coupled to disposable or reusable electrodes without the need for tools or threading. It is supplied in a box of 10 units (set of 10 pieces), designed for cardiology, monitoring and EEG departments with continuous demand for this reusable consumable.
2. Technical explanation
The signal chain is as follows: tab electrode (TAB) → adapter crocodile clip → 3–4 mm banana female socket → patient cable (4 mm male banana) → recording equipment. The crocodile clip is secured by its jaw over the electrode tab by applying pressure, while the universal female socket accepts the 3–4 mm banana connector, the most common standard on patient cables for ECG equipment. The result is a firm mechanical connection, stable signal transmission and quick repositioning between leads and patients. It is a reusable element in controlled clinical conditions, suitable for resting ECG and monitoring with crocodile clip leads, as well as for EEG and EMG studies.
3. Technical Specifications
Banana-to-crocodile clip connection adapter according to the manufacturer’s official catalogue (Product_DB.csv):
| Parameter | Specification |
|---|---|
| Type | Banana adapter (female 3–4 mm) to crocodile clip (alligator) |
| Connection to the electrode | Crocodile clip jaw on tab electrodes (TAB) |
| Cable connection | Universal 3–4 mm banana female socket |
| Sales unit | Set of 10 pieces (box of 10 units) |
| Applications | Resting ECG and monitoring, EEG, EMG and electrotherapy |
| Use | Reusable in a controlled clinical environment |
| Device type | Medical device (medical device) |
| Device class | I |
| CND | Z12050380 |
| GMDN | 31683 |
| EAN | 8033695721402 |
| Manufacturer | GIMA |
Available references
| SKU Cahnos | Manufacturer reference | Presentation |
|---|---|---|
| GM33376 | 33376 | Set of 10 pieces |
4. Equivalences and Cross-References
Reference 33376 corresponds to the product’s official factory code, verified in the manufacturer’s catalogue (universal 3–4 mm banana female socket to crocodile clip connection, pack of 10 pieces). No manufacturer-validated equivalence table is available cross-referencing this reference with codes from other brands; the alternatives indicated are comparable by category (not 1:1 interchangeable) and must be checked against their technical data sheet before any substitution: connector diameter, contact material, classification and presentation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Observations |
|---|---|---|---|---|
| FIAB (Italy) | 4 mm plug to alligator clip adapter (tab electrodes) | F9019 | Comparable by category (not interchangeable 1:1) | Same function: 4 mm connection to crocodile clip for TAB-type electrodes; check contact finish and presentation. |
| FIAB (Italy) | 4 mm socket to snap + alligator adapter clip, white | F9017W | Comparable by category (not interchangeable 1:1) | Adds integrated snap terminal; white ABS body, box of 10 units. |
| Lessa (Papeles Registrales, S.A.) | Crocodile clip adapter with 4 mm female connector (tab/TAB electrodes) | 99.113.21 | Comparable by category (not interchangeable 1:1) | Crocodile end only with 4 mm banana female socket; confirm contact finish. |
As a market compatibility reference, the 4 mm banana terminal is the standard commonly used by patient cables on ECG equipment from brands such as Aspel, Bionet, Cardioline, Cardioteck, Fukuda Denshi, Nihon Kohden or Burdick/Quinton. Specific references must be verified one by one before any possible substitution.
5. Selection tips and variants of interest
Check your cable terminal: this adapter is designed for patient cables with a 3–4 mm banana plug. If your cable ends in a 2 mm plug, please confirm the corresponding adaptation variant with our technical department.
Choose the terminal according to the electrode: use the crocodile jaw over the tab of TAB-type electrodes. A snap and a tab are not interchangeable with each other without the appropriate adapter; if you work mainly with snap electrodes, consider banana-to-snap adapters such as the PG922/4 series (kit of 10 pieces in colours) or the F9017W dual clip.
To complete the stock: combine these adapters with tab electrodes for crocodile clips (stamp-type format) and with the unipolar cables and leads of your electrocardiograph to replenish your resting ECG and monitoring material.
Use and storage: store in a dry place respecting the packaging conditions; it requires no special handling conditions and can be reused in a controlled clinical environment after cleaning as indicated by the manufacturer.
Institutional purchasing: in the absence of a manufacturer-validated equivalence table, request a sample or consult the technical-commercial department at Cahnos before fixing the reference in tender specifications. Product without a reference price: For large orders you can request a quote.





Reviews