Description
1. Commercial Introduction
The 3M™ RED DOT™ 2239 monitoring electrodes (reference 33297) are single-use disposable consumables designed for continuous electrocardiographic monitoring in adult patients. Their non-woven fabric support with micropore tape backing offers breathable, flexible, skin-friendly adhesion without compromising the signal stability that characterises one of the most recognised families of surface electrodes on the market.
They are supplied in a box of 1,000 units (20 sachets of 50 units), a high-performance format designed for the continuous supply of cardiology departments, ICUs, emergency departments, hospitalisation units and purchasing centres. As an original 3M electrode, it guarantees trace homogeneity and reliability in every monitoring session.
2. Technical Explanation
The monitoring electrode acts as an interface between the patient’s skin and the monitor or recording device: it captures the electrical activity of the heart and transmits it with the minimum possible distortion. Trace quality depends on three key factors: adhesion (the electrode must remain in place throughout the monitoring period), conductivity (low skin-electrode contact impedance) and stability against patient movement.
This model incorporates a non-woven fabric support with micropore tape backing, a breathable, flexible adhesion system that conforms to the patient’s chest contour and minimises irritation on sensitive skin, with a wear time of up to 3 days. Being single-use, it ensures hygiene and prevents cross-contamination: each monitoring session starts with a new electrode, with no further skin preparation than prior cleaning and drying.
3. Technical Specifications
ECG monitoring electrode for adult patients with the following main characteristics:
| Characteristic | Value |
|---|---|
| Type | Disposable, single-use monitoring electrode |
| Code 3M | 2239 |
| Diameter | Ø 6 cm |
| Support material | Non-woven fabric with micropore tape backing |
| Use duration | Up to 3 days |
| Population | Adult |
| Application | Continuous ECG monitoring |
| Use | Single-use, disposable |
| Presentation | Box of 1,000 units (20 sachets of 50 units) |
Product data
| Value | Value |
|---|---|
| Brand | 3M |
| Sales unit | Box of 1,000 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
Available references
| Reference / Code | Origin | Description |
|---|---|---|
| 33297 | SKU | 3M RED DOT 2239 – micropore monitoring electrodes, Ø 6 cm |
| GM33297 | SKU Cahnos | 3M RED DOT 2239 electrodes – box of 1,000 units (20 sachets of 50) |
| 2239 | Code 3M | RED DOT™ family – monitoring electrode with micropore backing |
Note: technical data are taken from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tendering.
4. Equivalences and Cross-References
Reference 33297 is the manufacturer’s official code for this 3M RED DOT 2239 electrode. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers must be understood as comparable by category (disposable monitoring electrode with non-woven backing, adult format) and never as interchangeable without verification.
Homologous families in this category include, always pending verification against the official technical data sheet, the monitoring electrodes from Skintact (Leonhard Lang), Ambu (WhiteSensor series), Kendall (Cardinal Health) and FIAB. Within the 3M™ RED DOT™ family itself, the 2238 electrode (soft cloth, Ø 6 cm, reference 33296) is the closest variant with soft fabric backing and removal tab; for the paediatric population, the family offers the 2248-50 (Ø 4.5 cm, reference 33299). Before any substitution, a field-by-field check must be carried out: diameter, backing material, target population and compatibility with the monitor lead wire connector.
5. Selection tips and variants of interest
Monitoring duration: this electrode with micropore backing offers up to 3 days of continuous use, suitable for ICU stays and hospitalisation. For longer monitoring periods, consider the foam series electrodes with adhesive gel from the RED DOT™ family (codes 2228 and 2244), which have greater skin adhesion.
Backing preference: if your department prefers a soft cloth non-woven fabric with removal tab and solid gel, consult the 3M RED DOT 2238 variant (ref. GM33296); if you need connection with a 4 mm adapter, the 2228BA variant (ref. GM33291) from the same family.
Equipment connection: verify the connector type and lead wire of your monitor or electrocardiograph before placing the order, as well as the purchase format (the box of 1,000 units is supplied in 20 sachets of 50 units).
Skin preparation: clean and dry the application area (chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeat measurements caused by poor signal.
Storage: single-use disposable product; keep the boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or deteriorates. For complete supplies or tenders, contact the technical-commercial department of Cahnos.





Reviews