Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with this kit of 10 replacement unipolar lead wires from the Italian manufacturer FIAB, reference F5377/KIT. This is the complete set of individual lead wires with male 4 mm connector (plug) and without protection against defibrillation discharge, designed to replace worn-out lead wires of ECG patient cables that use this connection system. Manufactured by FIAB SpA (Vicchio, Florence, Italy), it ensures stable transmission of the electrocardiographic signal in cardiology clinics, primary care, emergency departments and functional diagnostic centres. Product sold on quotation: contact our technical-commercial team to formalise your B2B terms.
2. Technical Explanation
The unipolar lead wire (individual lead cable) is the conductive wire that connects each electrode placed on the patient to the main cable or distributor of the electrocardiograph. In this reference, the patient end features a male 4 mm connector (banana plug), the classic coupling system for reusable clip electrodes and for numerous 10-lead ECG patient cables.
This version does not incorporate protection against defibrillation discharge, so it is intended for equipment in which the patient cable does not require integrated resistance to defibrillation energy; always verify the requirements of your electrocardiograph or patient cable. The kit includes standard lengths and colours to fully configure the patient leads, identifying each channel by colour code.
3. Technical specifications and tables
The manufacturer’s specifications, available references and main technical data for this lead wire kit are detailed below:
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F5377/KIT |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Available references
| Reference | Description |
|---|---|
| FIAB-F5377-KIT | Cahnos SKU for the kit of 10 lead wires, 4 mm plug connector, without protection |
| F5377/KIT | Official manufacturer reference FIAB |
Product technical data
| Parameter | Value |
|---|---|
| Brand | FIAB |
| Manufacturer / original distributor | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Kit of 10 replacement unipolar leads for ECG |
| Patient end connector | Male 4 mm (plug) |
| Protection against defibrillation discharge | Without protection |
| Number of leads | 10 |
| Kit composition | 6 leads of 100 cm + 4 leads of 120 cm |
| Colours of the 100 cm leads | Red, yellow, green, brown, black, violet |
| Colours of the 120 cm leads | Green, yellow, black, red |
| Classification in FIAB catalogue | ECG > Patient Cables > Accessories |
| Sales unit | Under quotation |
4. Equivalences and Cross-References
The reference FIAB F5377/KIT corresponds to the kit of 10 unipolar lead wires with male 4 mm connector and without protection against defibrillation discharge, marketed by Cahnos under the SKU FIAB-F5377-KIT; both references identify the same product and it is supplied in a pack of 1 unit. No official equivalence table has been found in reliable sources that would allow this reference to be substituted 1:1 with lead wires from other manufacturers: lead wires are accessories specific to the connection system (patient terminal type and connector on the main cable side), so they must always be checked against the technical data sheet of your electrocardiograph or patient cable.
Within the FIAB catalogue, comparable references can be consulted by category and connection system, without automatic interchangeability:
| Reference FIAB | Connection | Protection |
|---|---|---|
| F5377/KIT | 4 mm plug | Without protection (this product) |
| F5388/KIT | 4 mm plug | 4.7 KOhm |
| F5388R/KIT | 4 mm plug | 10 KOhm |
| F5386/KIT | Pinch | 4.7 KOhm |
| F5386R/KIT | Pinch | 10 KOhm |
| F5376/KIT | Pinch | Without protection |
| F5399/KIT | Snap | Without protection |
5. Selection tips and variants of interest
Verify the connection system of your patient cable or electrocardiograph: this reference features a male 4 mm (plug) connector at the patient end and is intended for 10-lead equipment that uses this termination. Also confirm the level of protection required by your equipment fleet: this kit (F5377/KIT) is the without protection version; if your working environment requires resistance to defibrillation discharge, consider the variants with the same 4 mm connector and 4.7 KOhm protection (ref. F5388/KIT) or 10 KOhm (ref. F5388R/KIT). If your wiring uses another type of terminal, consider the kits with pinch connection (refs. F5376/KIT, F5386/KIT and F5386R/KIT) or with snap connection (ref. F5399/KIT). It is recommended to periodically check the condition of the insulation, contacts and flexibility of the lead wires, replacing them at any sign of deterioration, breakage or loss of signal quality. As this is a product sold on quotation, contact the technical-commercial department of Cahnos to confirm exact compatibility with your equipment and obtain a formalised quotation under B2B terms.




Reviews