Description
1. Commercial Introduction
The Ambu® WhiteSensor 4200 ECG electrode is the trusted consumable for short-term electrocardiographic monitoring in adult patients. It produces and combines versatility, quality and functionality in a rectangular format of 28 x 44 mm with a snap connector, the most common standard in bedside monitor cables. Thanks to its solid conductive gel and its flexible foam backing, it ensures a good quality signal throughout the recording, reliable adhesion and comfort that patients appreciate in daily practice. Available in a box of 1,200 units (12 sachets of 100 units), it is the high-turnover solution for cardiology departments, emergency departments, outpatient clinics and procurement centres.
2. Technical Explanation
The surface ECG electrode acts as an interface between the patient’s skin and the monitor: it captures the electrical activity of the heart and transmits it to the monitoring system with the least possible distortion. The quality of the recording depends on three key factors: adhesion (the electrode must remain fixed throughout the test), conductivity (low skin-electrode contact impedance) and patient comfort.
The Ambu® WhiteSensor 4200 uses a solid conductive gel that ensures excellent signal quality in short-term ECG monitoring applications: being a solid gel, it maintains its aqueous content without leaking or shifting with sweat, which reduces motion artefacts and stabilises capture during the recording. Its flexible foam backing adapts to the contour of the chest, facilitates ease of application and provides comfort, while the flexible and reliable adhesive is able to follow skin movements without peeling off, improving patient experience and signal reliability. The connection is made via a snap-type press stud, compatible with most electrode cables on the market.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| AMBU code | 4200 |
| Description | WhiteSensor 4200 |
| Application | Short-term monitoring (Short-term) |
| Gel type | Solid |
| Backing material | Foam |
| Size (mm) | 28 x 44 |
| Shape | Rectangular |
| Shelf life (months) | 30 |
| Radiolucent | No |
| Connector type | Snap |
| Minimum order | Box of 1,200 units |
| Packaging / presentation | 12 pouches of 100 units |
Product data
| Parameter | Value |
|---|---|
| Brand | AMBU |
| Sales unit | Box of 1,200 units |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C020501 |
| GMDN | 35035 |
| Reference Cahnos (SKU) | GM53902 |
4. Equivalences and Cross-References
The reference 4200 (SKU Cahnos GM53902) corresponds to the official Ambu® WhiteSensor 4200 model. There is no manufacturer-validated equivalence table authorising a 1:1 cross-reference with third-party brands; the following references are offered as comparable by category (not interchangeable 1:1) and must be verified field by field (backing, gel, dimensions and connector) before any substitution:
| Manufacturer / Brand | Family / Model | Equivalence level | Observations |
|---|---|---|---|
| Ambu | WhiteSensor (family) | Same manufacturer family | The WhiteSensor range offers different configurations (solid/liquid gel, foam/fabric backing, sizes and connectors) depending on the duration of the recording; validate the exact reference. |
| Catalogue Cahnos | Long-term monitoring ECG electrode TNT Ø 55 mm (Ref. 0590014) | Comparable by category | Electrode with solid gel and snap connector for prolonged studies/Holter; differs in application (long duration) and backing (TNT, Ø 55 mm). |
| Catalogue Cahnos | ECG electrode for Holter T-601 S, medical paper Ø 55 mm (Ref. 16003) | Comparable by category | Solid gel and snap connection for prolonged monitoring; differs in backing (medical paper) and application (24-48 h). |
Since the type of backing, type of gel, dimensions and connector position affect adhesion and signal quality, any substitution must be validated against the manufacturer’s technical data sheet and the monitoring system used. Consult the technical department at Cahnos for reference homologation in tenders.
5. Selection tips and variants of interest
Select the electrode according to the duration of the recording: the Ambu® WhiteSensor 4200 is designed for short-term monitoring (brief recordings in the ward, consultation or emergency), where its solid gel and flexible foam backing provide a stable signal and excellent comfort. For Holter studies or prolonged monitoring of 24-72 h, consider in the Cahnos catalogue the long-term monitoring electrodes with solid gel and snap connector (Ref. 0590014 or 16003), which share the connection type but differ in backing and application.
Check the connector of your patient cable: this electrode features a snap-type stud, the most common standard in bedside monitors. If your fleet uses crocodile clips, banana connectors or tab connectors, consult the range of electrodes and connection adapters from Cahnos before selecting. Storage: keep the sachets closed in a dry, cool place, rotate stock on a FIFO basis and respect the expiry date indicated on the packaging (30 months); the solid gel may lose conductivity if the packaging is opened or damaged. Single-use device: dispose of it after each patient. For volume orders, complete supplies or tenders, contact the technical-commercial team at Cahnos.