We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Replacement filter electrodes for Quickels suction system – Pack of 128 units | Ag/AgCl AAMI sensor

129,00 €

Replacement filter electrodes for ECG suction electrode systems Quickels (ref. 70.11-2062 / MEC70.11-2062). Presentation of 128 units, compatible with all Quickels suction models, including the Decapus® II and Decapus® III systems. Each electrode incorporates an Ag/AgCl sensor that complies with AAMI recommendations, ensuring a stable and high-quality ECG signal. Manufactured from non-allergenic material, they offer a high hygienic factor, adhere effectively to the patient and are easily replaced, with performance comparable to that of adhesive electrode systems. Essential replacement consumable for cardiac monitoring in clinical settings.

Available on back-order

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC70.11-2062

Description

Section 1. Commercial Introduction

The filter electrodes for the Quickels suction system are the ideal replacement consumable for maintaining electrocardiographic monitoring in full working order with suction electrode systems. Available in a practical pack of 128 units, they are compatible with all models from the Quickels brand and guarantee a stable, clean and reliable ECG signal in every examination. A replacement designed for the day-to-day running of cardiology clinics, functional examination units and diagnostic services, combining hygiene, patient comfort and ease of use for the professional.

Block 2. Technical explanation of the equipment/procedure

ECG suction electrode systems, such as the Quickels line (Decapus® II and Decapus® III), keep the electrodes attached to the patient’s chest by suction, without the need for conventional adhesives. In this scheme, the filter electrode is the disposable piece that contacts the skin and acts as an interface between the patient and the suction system. Its highly absorbent design prevents moisture and salt residues from penetrating the inside of the equipment, helping to preserve its performance and extend its useful life.

Each electrode incorporates an Ag/AgCl sensor that complies with AAMI (Association for the Advancement of Medical Instrumentation) recommendations, resulting in a high-quality electrocardiographic recording with a good signal-to-noise ratio and minimal interference. Their manufacture from non-allergenic material makes them especially suitable for patients with sensitive skin, and their performance in use is comparable to that of conventional adhesive electrode systems.

Block 3. Technical specifications and tables

Product type Replacement filter electrodes (consumable)
Brand Quickels
Reference 70.11-2062 / MEC70.11-2062
Compatibility All models of the Quickels suction system (including Decapus® II and Decapus® III)
Presentation (VPE) Pack of 128 units
Sensor type Ag/AgCl
Material Non-allergenic
Standards / recommendations AAMI recommendations
Hygiene High hygienic factor; easy and quick replacement

Main characteristics

  • Effective adherence to the patient during the examination.
  • Easy replacement, without tools.
  • High hygienic factor: disposable element in contact with the patient.
  • Manufactured from non-allergenic material.
  • Ag/AgCl sensor compliant with AAMI recommendations.
  • Performance comparable to that of adhesive electrode systems.
  • They prevent moisture and residues from entering the suction system, preserving its useful life.

Section 4. Equivalences and Cross References

This product is marketed under the original reference 70.11-2062, equivalent to the management reference MEC70.11-2062 (distributor code of medical ECONET GmbH). It is the filter electrode designed by Quickels for its ECG suction systems, so the replacement reference must correspond to the Quickels system in use.

In the European market, specialised distributors market these same Quickels filter electrodes under designations such as QN500 or QN500.1 (sets of 128 units). If you have a Quickels Decapus® system and need to confirm exact compatibility with your equipment, our technical-commercial team can verify the reference before placing the order.

Section 5. Selection Tips and Relevant Variants

For always reliable ECG monitoring by suction, we recommend: verifying that the system in use corresponds to the Quickels range (e.g., Decapus® II or Decapus® III) before purchasing the replacement; always maintaining a sufficient stock of filter electrodes for daily activity, since they are the disposable part of the system; and replacing the filter electrode at each examination to preserve the high hygienic factor and signal quality. As a complement to your cardiology equipment, at Cahnos we offer other ECG monitoring consumables and accessories (electrodes, pads, cables and adapters). For large-volume orders or specific compatibility needs, request a personalised quote: this product is available on request.

Additional information

Manufacturer reference

70.11-2062

Product type

Replacement filter electrodes (consumable)

Compatibility

All models of the Quickels suction system (including Decapus II and Decapus III)

Presentation

Pack of 128 units

Sensor type

Ag/AgCl

Material

Non-allergenic

Regulatory standard

AAMI recommendations

Hygiene

High hygienic factor, easy replacement

Use

ECG monitoring with suction electrodes

Reviews

There are no reviews yet.

Be the first to review “Replacement filter electrodes for Quickels suction system – Pack of 128 units | Ag/AgCl AAMI sensor”

Your email address will not be published. Required fields are marked *