Description
1. Commercial Introduction
The disposable ECG electrodes for adults (ref. 54305) are the official replacement consumable for the Holter recorder ref. 54300. A product designed for cardiology departments, ambulatory diagnostic units, primary care practices and purchasing centres that need to keep their Holter fleet operational with a constant, reliable supply and excellent cost per procedure.
As it is the manufacturer’s original replacement, it guarantees mechanical and electrical compatibility with the cable and connector of the 54300 recorder, eliminating fitting uncertainties and ensuring recording quality from the first minute.
2. Technical Explanation
The surface ECG electrode acts as an interface between the patient’s skin and the Holter recorder: it captures the electrical activity of the heart and transmits it with the least possible distortion throughout the recording. Signal quality depends on three key factors: adhesion (the electrode must remain fixed throughout the test), conductivity (low skin-electrode contact impedance) and stability against movement.
This disposable electrode for adult use is placed on the patient’s chest using its medical-grade adhesive and maintains a stable electrical contact during 24-48 hour ambulatory recordings. Being single-use, it guarantees hygiene and prevents cross-contamination between patients: each study starts with a new electrode, ready to use, with no prior preparation or additional gel.
3. Technical Specifications
Product characteristics according to the manufacturer’s official catalogue (Product_DB):
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 54305 |
| SKU Cahnos | GM54305 |
| Product type | Disposable ECG electrodes for adults (replacement / spare) |
| Compatibility | Holter ECG recorder ref. 54300 |
| Population | Adult |
| Sales unit | Box of 10 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
| EAN | 6971457745117 |
Available references
| Manufacturer reference | SKU Cahnos | Description |
|---|---|---|
| 54305 | GM54305 | Disposable ECG electrodes for adults – replacement for 54300 – box of 10 units. |
Note: technical data are taken from the manufacturer’s official catalogue (.); confirm any specific value for use in tenders with the supplied batch data sheet.
4. Equivalences and Cross-References
The reference 54305 is the manufacturer’s official code for this replacement electrode for the Holter recorder 54300; no equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with codes from other brands.
As homologous families in the category (single-use disposable ECG electrode, with backing and conductive gel, for ambulatory monitoring in adults), the monitoring electrodes from Skintact (Leonhard Lang), Ambu, 3M/Solventum Red Dot, Kendall (Cardinal Health) and FIAB, as well as other ranges of disposable electrodes from the catalogue itself, may be cited, always pending verification against the official technical data sheet. They are not 1:1 interchangeable: each field must be verified (backing, gel type, diameter, connector and compatibility with the equipment cable) before any substitution.
5. Selection tips and variants of interest
Check your equipment: this reference is the indicated replacement for the Holter recorder ref. 54300. Check the exact model of your recorder and the type of patient cable connector before placing the order; if in doubt, contact the technical department of Cahnos indicating the model and serial number of your equipment.
Planned replenishment: as it is a single-use, high-turnover consumable, it is recommended to maintain a minimum stock per recording unit and rotate stock on a FIFO basis. Keep closed boxes in a dry, cool place and respect the expiry date indicated on the packaging; the conductive gel may lose conductivity if the packaging is opened or damaged.
Skin preparation: to optimise contact impedance and avoid repeats due to poor signal, clean and dry the application area (chest) before placing the electrodes, avoiding creams, hair or oily residues. For volume orders, complete sets or tenders, contact the technical-commercial department of Cahnos.





Reviews
There are no reviews yet.