Description
1. Introduction
The Ambu® WhiteSensor 4500M ECG electrodes (Ref. GM53912) are the reference consumable in the WhiteSensor range for exercise stress testing and short-duration ECG monitoring. Their combination of wet gel with good adhesion and a flexible foam backing ensures a stable electrocardiographic signal, rapid placement and a high level of comfort throughout the procedure. A reliable, high-turnover solution for cardiology departments, sports medicine units, diagnostic clinics and ergometry laboratories.
2. Technical explanation
The surface ECG electrode acts as an interface between the patient’s skin and the monitor or stress recorder: it captures the electrical activity of the heart and transmits it with the least possible distortion. In exercise stress testing, where the patient is in continuous movement and sweating heavily, three factors are critical: adhesion (the electrode must remain fixed throughout the protocol), conductivity (low skin-electrode contact impedance thanks to the wet gel) and backing flexibility.
The 4500M model uses a flexible foam backing that adapts to skin movements without peeling off, reducing motion artefacts and improving patient comfort. The wet gel provides excellent signal quality in short-duration monitoring such as ergometry or stress testing. Its snap connection is the most common standard in patient cables for monitors and exercise equipment, and its radiolucent construction allows it to be used without interference in radiological examinations.
3. Technical Specifications
Specifications of the Ambu® WhiteSensor 4500M electrode (Ref. 53912):
| Parameter | Value |
|---|---|
| Ambu code | 4500M |
| Description | WhiteSensor 4500M |
| Application | Exercise stress testing and short-duration monitoring |
| Gel type | Wet gel |
| Backing material | Foam |
| Dimensions (mm) | 50 x 48 |
| Shape | Round |
| Shelf life* (months) | 24 |
| Radiolucent | Yes |
| Connector type | Snap |
| Minimum order | Box of 300 units |
| Packaging | 10 bags of 30 units |
Product data:
| Field | Value |
|---|---|
| Brand | AMBU |
| Sales unit | Box of 300 units |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C020501 |
| GMDN | 35035 |
4. Equivalences and Cross-References
Reference GM53912 corresponds to the distribution code (Product_DB catalogue) of the Ambu WhiteSensor 4500M electrode. There is no equivalence table validated by the manufacturer that authorises 1:1 substitution with other brands; the following references are classified as comparable by category (not directly interchangeable) according to verified sources from the technical catalogue:
| Manufacturer / Brand | Family / Model | Reference | Equivalence level |
|---|---|---|---|
| Ambu (Denmark) | WhiteSensor CMM/1 – breathable textile electrode with solid gel for long-term monitoring | CMM-00-S | Comparable by category (differs in gel type and application: long-term monitoring versus exercise stress testing) |
| FIAB (Italy) | F2080 – non-woven electrode with solid gel, Ø 55 mm, snap connection | F2080 (Gima distribution ref. 33327) | Comparable by category (differs in backing and gel type) |
| 3M / Solventum | Red Dot Monitoring Electrode – foam with solid adhesive gel, snap connection | 2560 (V2560-5) | Comparable by category (differs in gel type) |
| Cardinal Health | Kendall Medi-Trace 530 Series – foam for monitoring, snap connection | 31013926 | Comparable by category (differs in indication: Holter/monitoring) |
Before any substitution, the critical fields must be verified one by one: backing (foam versus non-woven or paper), gel type (wet versus solid), dimensions, shape and connector. Consult the Cahnos technical department before using this reference in tenders or stock substitutions.
5. Selection tips and variants of interest
Select the electrode according to the duration and type of recording: the WhiteSensor 4500M, with wet gel and foam backing, is the optimal choice for exercise stress testing (stress test) and short-duration ECG monitoring, where immediate signal quality and effective fixation during exercise are required. For prolonged monitoring (Holter, long stay), consider solid-gel electrodes with fabric or foam backing from the Cahnos monitoring range, which maintain their conductivity for hours without drying out.
Check the connector on your patient cable: this electrode features a snap connection, the most common standard in stress monitor and bedside cables. If your installed base uses crocodile clips or other connectors, consult the Cahnos range of electrodes and adapters. To optimise skin-electrode contact, correct prior cleaning of the skin and the use of the catalogue’s preparation gels are recommended. Keep the bags closed in a cool, dry place, rotate stock on a FIFO basis and respect the 24-month expiry date indicated on the packaging. For volume orders, complete supplies or tenders, contact the Cahnos technical-commercial department.





Reviews
There are no reviews yet.