Description
1. Commercial Introduction
The 3M™ RED DOT™ 2228BA monitoring electrodes (reference 33291 / SKU Cahnos GM33291) are single-use disposable consumables, designed for continuous electrocardiographic monitoring in adult patients. Their foam backing with proprietary adhesive gel provides firm, flexible and comfortable fixation that adapts to the thoracic contour, with the signal stability that characterises one of the most recognised surface electrode families on the market.
They are supplied in a box of 800 units (20 sachets of 40 units), a high-performance format designed for the continuous supply of cardiology, ICU, emergency, hospitalisation units and purchasing centres. As an original 3M electrode, it guarantees trace homogeneity and reliability in every monitoring session.
2. Technical Explanation
The monitoring electrode acts as an interface between the patient’s skin and the monitor or recording equipment: it captures the electrical activity of the heart and transmits it with the minimum possible distortion. The quality of the trace depends on three key factors: adhesion (the electrode must remain fixed throughout the monitoring), conductivity (low skin-electrode contact impedance) and stability against patient movement.
This model incorporates a foam adhesive tape (foam-tape backing) and a proprietary adhesive gel that ensure excellent skin contact. Its thickness allows rapid application and acts as a filler and cushion over connections or irregular surfaces, improving fixation in difficult anatomical areas. It features a banana connection via an integrated 4 mm adapter, allowing direct use with patient lead cables of this standard, which is very common in multiparameter monitors and electrocardiographs. Being single-use, it guarantees hygiene and prevents cross-contamination between patients.
3. Technical Specifications
Foam ECG monitoring electrode with 4 mm adapter, with the following main features:
| Characteristic | Value |
|---|---|
| Type | Disposable, single-use monitoring electrode |
| Code 3M | 2228BA |
| Measurements | 3.71 x 3.25 cm |
| Support material | Foam (foam tape) with proprietary adhesive gel |
| Connection | 4 mm (banana) adapter |
| Population | Adult |
| Application | Continuous ECG monitoring |
| Use | Single-use, disposable |
| Presentation | Box of 800 units (20 sachets of 40 units) |
Product data
| Brand | 3M |
|---|---|
| Sales unit | Box of 800 pieces |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
Available references
| Reference / Code | Origin | Description |
|---|---|---|
| 33291 | SKU | 3M RED DOT 2228BA FOAM ELECTRODES – 3.71 x 3.25 cm |
| GM33291 | SKU Cahnos | 3M RED DOT 2228BA electrodes – box of 800 units (20 sachets of 40) |
| 2228BA | Code 3M | RED DOT™ family – foam monitoring electrode with 4 mm adapter |
Note: technical data are taken from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tendering.
4. Equivalences and Cross-References
Reference 33291 is the manufacturer’s official code for this 3M RED DOT 2228BA electrode, identified by the 3M code 2228BA. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers must be understood as comparable by category (disposable foam monitoring electrode with adhesive gel, adult format) and never as interchangeable without verification. As homologous families in the category, the monitoring electrodes from Skintact (Leonhard Lang), Ambu (WhiteSensor series), Kendall (Cardinal Health) and FIAB may be cited, always subject to verification against the official technical data sheet.
Within the 3M™ RED DOT™ family itself, the closest variants are:
| Reference Cahnos | Code 3M | Description |
|---|---|---|
| GM33290 | 2228 | Foam electrode with adhesive gel, 3.71 x 3.25 cm (box of 1000 units) |
| GM33291 | 2228BA | Foam electrode with 4 mm adapter, 3.71 x 3.25 cm |
| GM33292 | 2244 | Foam electrode with adhesive gel, 4 x 3.25 cm |
| GM33293 | 2570 | Foam electrode with adhesive gel, 4 x 3.5 cm |
| GM33296 | 2238 | Soft cloth non-woven electrode, Ø 6 cm |
| GM33297 | 2239 | Non-woven electrode with micropore, Ø 6 cm |
Before any substitution, a field-by-field check must be performed: dimensions, backing material, gel type, target population and compatibility with the monitor’s lead cable connector.
5. Selection tips and variants of interest
Equipment connection: this electrode incorporates a 4 mm (banana) adapter. Check the connector type of your monitor’s or electrocardiograph’s lead cables; if your installed base uses a connection without an integrated adapter, consult the 3M RED DOT 2228 variant (ref. GM33290) from the same foam family.
Backing preference: if your department prefers a more breathable non-woven backing instead of foam, consider the 3M RED DOT 2238 (ref. GM33296) and 2239 (ref. GM33297) models, both Ø 6 cm.
Purchase format: the box of 800 units is supplied in 20 sachets of 40 units, which facilitates stock management and rotation in the department. For lower volume needs, consult the box presentations of 50 units of other models in the range.
Skin preparation: clean and dry the application area (chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeats due to poor signal.
Storage: single-use disposable product; keep the boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or deteriorates. For complete supplies or tenders, contact the technical-commercial department of Cahnos.