We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

3M™ RED DOT™ 2228 ECG monitoring electrodes – Foam with adhesive gel, 3.71 x 3.25 cm – Box of 1,000 units (20 sachets of 50) (Ref. 33290)

118,75 €

Disposable ECG monitoring electrodes from the 3M™ RED DOT™ (code 2228) series, with foam backing and proprietary adhesive gel that ensures excellent skin-electrode contact and a stable signal throughout monitoring. Format 3.71 x 3.25 cm, radiotransparent and with a use duration of up to 3 days, ideal for continuous monitoring in ICU, emergency departments, hospitalisation units and stress tests. Presentation in a box of 1,000 units (20 sachets of 50 units), designed for the continuous supply of cardiology departments and purchasing centres. Class I medical device from the 3M brand, distributed in Spain by Cahnos. For large orders you can request a quote: contact our technical-commercial department.

Sales unit: caja de 1000
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33290

Description

1. Commercial Introduction

The monitoring electrodes 3M™ RED DOT™ 2228 (reference 33290 / SKU Cahnos GM33290) are single-use disposable consumables, designed for continuous electrocardiographic monitoring in adult patients. Their foam backing with proprietary adhesive gel offers firm, flexible and comfortable fixation that adapts to the chest contour, with the signal stability that characterises one of the most recognised families of surface electrodes on the market.

They are supplied in a box of 1,000 units (20 sachets of 50 units), a high-performance format designed for the continuous supply of cardiology departments, ICUs, emergency departments, hospitalisation units and purchasing centres. As an original 3M electrode, it guarantees trace homogeneity and reliability in every monitoring session.

2. Technical Explanation

The monitoring electrode acts as an interface between the patient’s skin and the monitor or recording device: it captures the heart’s electrical activity and transmits it with the minimum possible distortion. Trace quality depends on three key factors: adhesion (the electrode must remain fixed throughout the monitoring period), conductivity (low skin-electrode contact impedance) and stability against patient movement.

This model incorporates a foam adhesive tape (foam-tape backing) and a proprietary adhesive gel that ensure excellent skin contact. It is radiotransparent, so it does not interfere with imaging studies or X-rays, and offers a use duration of up to 3 days, designed for medium and long-stay monitoring. Being single-use, it guarantees hygiene and prevents cross-contamination: each monitoring session begins with a new electrode, with no further skin preparation than prior cleaning and drying.

3. Technical Specifications

Foam ECG monitoring electrode with the following main features:

Characteristic Value
Type Disposable, single-use monitoring electrode
Code 3M 2228
Measurements 3.71 x 3.25 cm
Support material Foam (foam tape) with proprietary adhesive gel
Use duration Up to 3 days
Radiotransparency Yes
Population Adult
Application Continuous ECG monitoring
Use Single-use, disposable
Presentation Box of 1,000 units (20 sachets of 50 units)

Product data

Value Value
Brand 3M
Sales unit Box of 1,000 pieces
Device type Medical device
Device class I
CND C020501

Available references

Reference / Code Origin Description
33290 SKU 3M RED DOT 2228 FOAM ELECTRODES – 3.71 x 3.25 cm
GM33290 SKU Cahnos 3M RED DOT 2228 electrodes – box of 1,000 units (20 sachets of 50)
2228 Code 3M RED DOT™ family – monitoring electrode with foam backing and adhesive gel

Note: the technical data come from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tendering.

4. Equivalences and Cross-References

Reference 33290 is the manufacturer’s official code for this 3M RED DOT 2228 electrode, identified by the 3M code 2228. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers must be understood as comparable by category (disposable monitoring electrode with foam backing and adhesive gel, adult format) and never as interchangeable without verification.

As homologous families in the category, always subject to verification against the official technical data sheet, the monitoring electrodes from Skintact (Leonhard Lang), Ambu (WhiteSensor series), Kendall (Cardinal Health) and FIAB can be cited.

Within the 3M™ RED DOT™ family itself, the closest variants are:

Reference Cahnos Code 3M Description
GM33290 2228 Foam electrode with adhesive gel, 3.71 x 3.25 cm (box of 1,000 units)
GM33291 2228BA Foam electrode with 4 mm adapter, 3.71 x 3.25 cm
GM33292 2244 Foam electrode with adhesive gel, 4 x 3.25 cm
GM33293 2570 Foam electrode with adhesive gel, 4 x 3.5 cm (up to 5 days)
GM33296 2238 Soft cloth non-woven electrode, Ø 6 cm
GM33297 2239 Non-woven electrode with micropore, Ø 6 cm
GM33299 2248-50 Paediatric non-woven fabric electrode with micropore, Ø 4.5 cm
GM33378 2330 Pregelled electrode for resting ECG, 3.2 x 2.2 cm

Before any substitution, a field-by-field check must be carried out: dimensions, backing material, gel type, target population and compatibility with the monitor’s lead wire connector.

5. Selection tips and variants of interest

Equipment connection: check the connector type and lead wire of your monitor or electrocardiograph; if connection via a 4 mm adapter is required, consult the 3M RED DOT 2228BA variant (ref. GM33291) from the same foam family.

Monitoring duration: this foam electrode offers up to 3 days of continuous use, suitable for ICU and hospitalisation stays. For prolonged monitoring of up to 5 days, the RED DOT™ family offers model 2570 (ref. GM33293), with a slightly larger format of 4 x 3.5 cm.

Backing preference: if your department prefers a more breathable non-woven fabric backing instead of foam, consider the 3M RED DOT 2238 (ref. GM33296) and 2239 (ref. GM33297) models, both Ø 6 cm; for the paediatric population, the 2248-50 (ref. GM33299).

Skin preparation: clean and dry the application area (chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeats due to poor signal.

Storage: single-use disposable product; keep the boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or deteriorates. For complete supplies or tenders, contact the technical-commercial department at Cahnos.

Additional information

Manufacturer reference

33290

Code 3m

2228

Measurements

3.71 x 3.25 cm

Backing material

Foam (foam tape) with proprietary adhesive gel

Use duration

Up to 3 days

Radiotransparency

Yes

Application

Continuous ECG monitoring

Use

Single-use, disposable

Presentation

Box of 1,000 units (20 sachets of 50 units)

Unit of sale

Box of 1,000 pieces

CND code

C020501

Presentacion

Box of 1000

Tipo dispositivo

Medical device

Clase sanitaria

I

Tipo paciente

Adult

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “3M™ RED DOT™ 2228 ECG monitoring electrodes – Foam with adhesive gel, 3.71 x 3.25 cm – Box of 1,000 units (20 sachets of 50) (Ref. 33290)”

Your email address will not be published. Required fields are marked *