Description
Introduction
The 23G subarachnoid anaesthesia needle is the ideal solution for anaesthesiology professionals seeking safe, precise and minimally traumatic access to the subarachnoid space. With a 23G gauge (approximate outer diameter of 0.63 mm) and available in lengths of 7, 9 and 11 cm, it allows the technique to be adapted to each patient and procedure, ensuring an effective, rapid and reliable anaesthetic block with maximum comfort and clinical safety.
Technical explanation
Subarachnoid anaesthesia (also called spinal or intradural) involves the administration of local anaesthetic into the cerebrospinal fluid of the subarachnoid space, achieving a deep sensory and motor block for lower abdominal, urological, trauma, obstetric and lower limb surgery. The 23G gauge offers an excellent balance between insertion rigidity, smooth injection flow and a moderate dural puncture size, favouring spontaneous sealing of the dura mater and limiting the incidence of post-dural puncture headache. Its sharp tip with a Quincke-type bevel facilitates controlled penetration through the ligamentous planes, while the stylet obturator ensures lumen patency, precise bevel orientation and correct confirmation of cerebrospinal fluid outflow. It is a sterile, disposable and single-use product that ensures maximum protection against cross-infection.
Technical specifications
| Characteristic | Specification |
| Gauge | 23G (approx. outer diameter 0.63 mm) |
| Available lengths | 7 cm, 9 cm and 11 cm (70 / 90 / 110 mm) |
| Tip type | Sharp with Quincke-type bevel |
| Material | Medical-grade stainless steel |
| Stylet | Included, with stylet |
| Connection | Standard Luer hub |
| Use | Single-use |
| Sterility | Sterile, individual packaging |
| Reference | DJECT23 |
Equivalences and cross-references
This needle is a high-quality generic alternative equivalent to the leading spinal needles on the market in 23G gauge, such as Spinocan® from B. Braun, BD® Quincke or the Quincke-type spinal needles from Dalhausen and Vygon. It is compatible with the usual practice of orienting the bevel parallel to the dural fibres to reduce cerebrospinal fluid loss. Indicative market references:
| Manufacturer / Series | Indicative reference |
| B. Braun Spinocan® | 0.63 × 88/90 mm (approx.) |
| BD Quincke | 0.63 × 90 mm |
| Dalhausen (Quincke type) | 76.111.23.xxx (70 / 90 / 110 mm) |
| Vygon | Series 2779 / 2780 (23G) |
Selection tips and variants of interest
For adult patients with standard anatomy, the 9 cm length is recommended; the 7 cm version is suitable for slim patients or low lumbar levels, while the 11 cm version facilitates access in patients with a larger panniculus adiposus. The 23G gauge is an excellent option when a more fluid injection flow and greater insertion rigidity than fine gauges are required, while maintaining a contained dural profile. If the service prefers to further minimise post-dural puncture headache, the 25G, 26G and 27G variants (DJECT25, DJECT26 and DJECT27) can be considered. If greater flow and rigidity are required for specific techniques, please consult the 22G version (DJECT22). For combined spinal-epidural techniques or continuous anaesthesia, we recommend considering our spinal kits and atraumatic pencil-point needles, available on request through the commercial department.







Reviews
There are no reviews yet.