We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Chiba tip needle 21G with echogenic marker for cytological biopsy (PAAF) and suction – Sterile, single-use (Ref. CHGA21)

175,00 €

Disposable Chiba tip needle, 21G, with distal echogenic marker, indicated for cytological biopsy and fine needle puncture-suction (PAAF/BAAF) guided by ultrasound imaging, suction of cysts and administration of anaesthetics. Its long, sharp bevel penetrates smoothly preserving cellular integrity; graduated cannula with depth stabiliser and hub compatible with syringes and suction guns. Sterile, single-use and latex-free, available in lengths of 10, 15, 20 and 25 cm. Reference CHGA21.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
CHGA21

Description

1. Introduction

The disposable Chiba tip needle, gauge 21G (ref. CHGA21), is the reference instrument for interventional radiology, prenatal diagnosis, digestive and oncology departments that perform ultrasound-guided punctures. Its design with Chiba tip and distal echogenic marker significantly improves real-time ultrasound visualisation, allowing the tip to be placed precisely even in anatomically difficult areas. A reliable, sterile, single-use solution for cytological diagnosis in hospitals, private clinics and diagnostic imaging centres.

2. Technical explanation of the equipment and procedure

The Chiba-type needle is the international standard for fine-needle aspiration (FNA/FNAB). Its long, sharp bevel penetrates tissues with lower insertion force and a more predictable trajectory, preserving the cellular integrity of the sample for reliable cytological diagnosis. The distal echogenic marker produces a clear contrast on the ultrasound image, allowing the needle path to be followed in real time, correcting the trajectory during puncture and reducing the risk of damaging surrounding structures.

The centimetre-graduated cannula with depth stabiliser facilitates exact control of penetration, and the transparent hub ensures a secure connection with aspiration syringes and guns. Being a sterile, single-use device, the risk of cross-contamination between patients is completely eliminated.

3. Technical specifications and tables

The CHGA21 needle is manufactured from medical-grade stainless steel, is sterile (ethylene oxide sterilisation) and is supplied in individual packaging. Its international colour code instantly identifies the gauge.

Parameter Specification
Reference Cahnos CHGA21
Gauge 21G (approx. 0.80 mm outer diameter)
Tip type Chiba (long, sharp bevel) with distal echogenic marker
Available lengths 10, 15, 20 and 25 cm
Material Medical-grade stainless steel
Connection Transparent hub; compatible with syringes and aspiration guns
Marking Centimetre-marked cannula with depth stabiliser
Identification Gauge colour code (green for 21G)
Sterility Sterile, disposable, single-use (EtO); latex-free
Presentation Individual packaging; box of 20 units
Application Cytological biopsy, ultrasound-guided fine-needle aspiration (FNA/FNAB), cyst aspiration, prenatal biopsy and administration of anaesthetics
Regulatory classification Medical device Class IIa (CE marking)

Range of disposable Chiba tip needles from Cahnos

Reference Cahnos Gauge Lengths (cm)
CHGA18 18G 10, 15, 20 and 25
CHGA20 20G 10, 15, 20 and 25
CHGA21 21G 10, 15, 20 and 25
CHGA22 22G 10, 15, 20 and 25

4. Equivalences and Cross-References

The Chiba-type tip geometry with echogenic marker and centimetre-graduated cannula makes this reference clinically comparable to standard cytological aspiration Chiba needles on the European and international market, with the same applications (FNA, cyst aspiration, amniocentesis and local anaesthesia) and compatibility with aspiration syringes and guns. The following references have been cross-checked against the official catalogue or corresponding manufacturer documentation:

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
BD (Becton Dickinson) Chiba Fine Needle Aspiration Needle CHI2115 (21G × 15 cm) / CHI2120 (21G × 20 cm) Comparable by category (not interchangeable 1:1) Chiba tip with bevel for cytological aspiration, centimetre depth marks, transparent hub and echogenic tip; lengths 15 and 20 cm matching the CHGA series.
Cook Medical Chiba Biopsy Needle (with EchoTip version) DCHN-21-15.0 (G00778) / DCHN-21-20.0 (G00895) / DCHN-21-15.0-U (G04586, EchoTip) Comparable by category (not interchangeable 1:1) Same indication for cytological aspiration and equivalent length range; verify hub, depth stop and stylet configuration. The ‘-U’ version incorporates an echogenic EchoTip tip.

There is no manufacturer-validated equivalence table declaring these references as 1:1 interchangeable; the comparison is functional and categorical, so the technical department must be consulted before use in tenders or direct substitution.

Within the Cahnos catalogue, the alternative in 21G gauge without echogenic marker is the disposable Chiba needle ref. BIOCHIBACPL003, and the echo-reflective version ref. BIOCHIBAECHO003. For MRI-compatible punctures, ref. CAHCHIBA (Complete-Chiba® non-magnetic) is available, and if the procedure requires combined cytological and microhistological sampling, the modified Menghini cutting series with total retrieval (e.g. FULLOPTY21/FULLOPTY22) may be considered. As a sector reference, B. Braun markets 21G echogenic Chiba tip introducer needles (e.g. ref. 612131), although their primary function is as an access introducer rather than direct cytological aspiration.

5. Selection tips and variants of interest

Select the length according to lesion depth and approach route: 10 cm for superficial lesions or short accesses, 15 cm as the standard option in guided cytological biopsy, and 20–25 cm for deep lesions or patients with greater adipose panniculus.

The 21G gauge is particularly indicated for delicate accesses (prenatal, thyroid, breast or sensitive tissue biopsy) where the aim is to minimise patient discomfort without compromising a representative cell sample. If the procedure requires a larger sample volume in deep tissues, the 18G (CHGA18) or 20G (CHGA20) gauges from the same family may be considered; for maximum delicacy, the 22G (CHGA22) gauge completes the range. For procedures requiring additional histological sampling, consider an automatic biopsy gun system.

Our technical-commercial team is at your disposal to confirm availability, quotation conditions, volume orders and adaptation to public tender specifications.

Additional information

Reference

CHGA21

Gauge

21G (approx. 0.80 mm outer diameter)

Tip type

Chiba with distal echogenic marker

Available lengths

10, 15, 20 and 25 cm

Material

Medical-grade stainless steel

Connection

Transparent hub compatible with syringes and aspiration guns

Marking

Centimetre-marked cannula with depth stabiliser

Colour code

Green (21G)

Sterilisation

Ethylene oxide (EtO)

Presentation

Sterile, disposable, single-use; individually packaged, box of 20 units

Application

Cytological biopsy, ultrasound-guided FNAB/FNAC, cyst aspiration, prenatal biopsy, anaesthetic administration

Latex-free

Yes

Regulatory classification

Medical device Class IIa (CE marking)

Reviews

There are no reviews yet.

Be the first to review “Disposable Chiba tip needle 21G with echogenic marker for cytological biopsy (PAAF) and suction – Sterile, single-use (Ref. CHGA21)”

Your email address will not be published. Required fields are marked *