Description
1. Introduction
The echo-reflective 18G Chiba-type cytological biopsy needle from Cahnos is the reference instrument for interventional radiology, prenatal diagnosis, gastroenterology and oncology services that perform ultrasound-guided punctures. Its echogenic tip design significantly improves real-time ultrasound visualisation, allowing exact placement of the tip even in anatomically difficult-to-access areas. A reliable solution for cytological diagnosis in hospital settings, private clinics and diagnostic imaging centres.
2. Technical explanation of the equipment and procedure
The Chiba-type design is an international standard in fine-needle aspiration biopsy (BAAF/PAAF). Its tip features a sharp bevel that facilitates clean tissue penetration without tearing, preserving sample integrity for reliable cytological diagnosis. The echo-reflective tip technology generates a marked contrast on the ultrasound image, allowing the specialist to track the needle path in real time, correct the trajectory during puncture and reduce the risk of damaging surrounding structures. The centimetric marking allows exact depth control and the 18G calibre offers an optimal balance between sample diameter, cannula rigidity and patient comfort, making it ideal for obtaining an abundant cell sample.
3. Technical Specifications
Made of high-quality stainless steel, it is a sterile, single-use product, individually packaged. Its international colour code facilitates immediate identification of the calibre.
| Characteristic | Specification |
| Gauge | 18G (1.20 mm outer diameter) |
| Available lengths | 11 cm, 15 cm and 20 cm |
| Tip type | Chiba with echo-reflective treatment |
| Visualisation technology | Echo-reflective / echogenic |
| Marking | Centimetric for depth control |
| Material | High-quality stainless steel |
| Identification | International colour code for the gauge |
| Sterility | Sterile, disposable, single-use |
| Presentation | Individual packaging |
| Main use | Cytological biopsy and ultrasound-guided aspiration (PAAF/BAAF) |
| Reference | BIOCHIBAECHO001 |
Echo-reflective range of Chiba needles available in the catalogue:
| Gauge | Lengths | Reference |
| 18G | 11, 15 and 20 cm | BIOCHIBAECHO001 / BIOCHIBAECHO001-B |
| 20G | 7, 9, 11, 15 and 20 mm | BIOCHIBAECHO002 |
| 21G | 7, 9, 11, 15 and 20 mm | BIOCHIBAECHO003 |
| 22G | 7, 9, 11, 15 and 20 mm | BIOCHIBAECHO004 |
| 25G | 5, 7 and 9 mm | BIOCHIBAECHO005 |
4. Equivalences and Cross-References
This needle belongs to the family of Chiba-type needles with an echogenic tip for cytological aspiration and ultrasound-guided biopsy, comparable to the Chiba series with echogenic marker from other European manufacturers (centimetric marking, cannula with echo-contrast treatment and international colour code). The standard 18G variant in the catalogue is BIOCHIBAECHO001, while BIOCHIBAECHO001-B is distinguished by its specific commercial configuration. As a Chiba-tip equivalent in 18G calibre, it is available in the disposable CHGA series (reference CHGA18) and, as a variant without echo-reflective treatment of the same family, in reference BIOCHIBACPL001 (disposable Chiba 18G). For procedures requiring dual cytological and microhistological sampling, the modified Menghini cutting needle series with total retrieval (e.g. FULLOPTY18) may be considered, and if the puncture must be performed under magnetic resonance imaging, reference CAHCHIBA (non-magnetic Complete-Chiba®) from the MRI biopsy range. Consult our technical-commercial department to validate the correspondence with your usual supply brand.
5. Selection tips and variants of interest
Select the 11 cm length for superficial lesions and short access routes, the 15 cm length as the standard option in guided cytological biopsy, and the 20 cm length for deep lesions or patients with a larger panniculus adiposus. The 18G calibre is ideal when an abundant cell sample is required while maintaining a moderate diameter and good cannula rigidity; for small or difficult-to-access lesions, you may opt for the 20G (BIOCHIBAECHO002), 21G (BIOCHIBAECHO003), 22G (BIOCHIBAECHO004) or 25G (BIOCHIBAECHO005) calibres from the same echo-reflective range. For biopsies requiring additional histological samples, consider an automatic biopsy system with a gun. Our technical-commercial team is at your disposal to help you configure the most appropriate calibre and length for your puncture protocol and hospital purchasing policy.





Reviews
There are no reviews yet.