Description
1. Commercial Introduction
Stiefel biopsy punches are the reference solution for rapid, reliable and hygienic sampling of skin tissue. Sterilised and ready to use, they completely eliminate the sharpening and sterilisation operations associated with reusable instruments, saving time in the consulting room and eliminating the risk of cross-contamination. With a range of 7 diameters covering 2 to 8 mm, the appropriate gauge is available for each lesion and each specialty: dermatology, family medicine, minor ambulatory surgery and histopathological diagnostics.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the entire skin, including complete epidermis and dermis for histopathological study. The seamless circular cutting edge in stainless steel provides a constantly smooth and regular cutting surface, allowing a clean incision with minimal damage to the surrounding tissue and optimum specimen quality.
The fluted handle offers a secure grip and precise control during rotation of the instrument, while the diameter engraved on each punch facilitates immediate identification, preventing errors in the operating theatre or consulting room. Each unit is supplied sterile and ready to use, guaranteeing sterility until the moment of opening.
3. Technical Specifications
Available references
| Reference | Diameter | Sales unit | Details |
|---|---|---|---|
| GM22650 | 2 mm | box of 10 pcs | Stiefel code: STIEF-BP2 · Biopsy punches: Ø 2 mm · STERILE |
| GM22651 | 3 mm | box of 10 pcs | Stiefel code: STIEF-BP3 · Biopsy punches: Ø 3 mm · STERILE |
| GM22652 | 3.5 mm | box of 10 pcs | Stiefel code: STIEF-BP35 · Biopsy punches: Ø 3.5 mm · STERILE |
| GM22653 | 4 mm | box of 10 pcs | Stiefel code: STIEF-BP4 · Biopsy punches: Ø 4 mm · STERILE |
| GM22654 | 5 mm | box of 10 pcs | Stiefel code: STIEF-BP5 · Biopsy punches: Ø 5 mm · STERILE |
| GM22655 | 6 mm | box of 10 pcs | Stiefel code: STIEF-BP6 · Biopsy punches: Ø 6 mm · STERILE |
| GM22656 | 8 mm | box of 10 pcs | Stiefel code: STIEF-BP8 · Biopsy punches: Ø 8 mm · STERILE |
Product data
| Brand | Stiefel |
|---|---|
| Manufacturer | GIMA |
| Sales unit | Box of 10 units |
| Blade material | Seamless stainless steel, sharp edge |
| Handle | Fluted (grooved) handle for a firm, precise grip |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Use | Disposable, single-use |
| Application | Skin / cutis biopsy: representative cross-section (epidermis and dermis) |
| Device type | Medical device (Medical device) |
| Device class | II A |
4. Equivalences and Cross-References
This family of biopsy punches shares the same technical principle as the single-use sterile skin biopsy punches from the main manufacturers on the market: a seamless circular stainless steel cutting edge, fluted handle, size engraved on each unit and individual sterile presentation. The cross-references indicated are category comparisons verified against official catalogues and regulatory sources (GUDID); as these are different manufacturers, they are not 1:1 interchangeable and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level |
|---|---|---|---|
| Stiefel (GSK-Stiefel) | Stiefel Biopsy Punch | SZ1983, SZ1984, SZ1985, SZ1986, SZ1988 | Comparable by category (not interchangeable 1:1) |
| KAI Medical | Sterile Biopsy Punch | BP-30F, BP-40F, BP-50F, BP-60F, BP-80F | Comparable by category (not interchangeable 1:1) |
| (Italy) | Stiefel-type biopsy punches | 22584, 22585, 22586, 22587, 22588, 22605 | Comparable by category (same distributor, different line) |
| Integra Miltex | Sterile Disposable Biopsy Punch | 33-32, 33-34, 33-35, 33-36, 33-37 | Comparable by category (not interchangeable 1:1) |
No equivalence table has been validated by the manufacturer; the above cross-references are technical comparisons by category contrasted against official catalogues and regulatory sources (GUDID). For exact equivalences in tender processes, consult your technical-commercial advisor at Cahnos.
5. Selection tips and variants of interest
The punch diameter determines the size of the specimen and should be chosen according to the lesion and the intended histopathological study:
- 2 mm: very small lesions, aesthetic areas and paediatric patients, minimising scarring.
- 3–4 mm: standard range in dermatology for most skin lesions, with a highly representative specimen.
- 5–6 mm: greater amount of tissue or medium-sized lesions.
- 8 mm: large lesions, more extensive excisions or studies requiring a voluminous specimen with complete epidermis and dermis.
Keep the full range of diameters (2, 3, 3.5, 4, 5, 6 and 8 mm) available in the department to cover any indication with the same supplier and quality. Check the integrity of the individual packaging before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations. For large orders you may request a quote: consult your technical-commercial advisor at Cahnos for terms and lead times.