Description
1. Introduction
The Endotracheal Tube ENDOSID Magill without cuff and without Murphy eye 3 mm (Ref. 842030) is a single-use medical device designed for safe airway management in neonates, infants and patients with very small airways. Its minimalist design combines the classic Magill curvature with the absence of an inflation cuff and lateral eye, offering professionals a precise, reliable and easy-to-handle solution in critical settings such as the neonatal intensive care unit (NICU), the paediatric operating theatre and emergency services. A reliable choice for anaesthesia and emergency teams that need maximum control and safety in particularly vulnerable patients.
2. Technical Explanation
The endotracheal tube is a device inserted into the trachea to secure a patent airway and allow mechanical ventilation or administration of anaesthesia. The Magill configuration, with its characteristic proximal curvature, facilitates insertion in small patients and allows the tip to be directed towards the glottic opening with greater control. As it has no inflation cuff, sealing is achieved through the natural fit of the calibre against the tracheal mucosa, which minimises the risk of pressure injury in immature airways and avoids mucosal compression. The absence of a Murphy eye ensures a completely smooth and continuous internal lumen, with no elements that could trap secretions or interfere with airflow, providing a direct, unobstructed passage. Its transparent material allows the patency of the circuit to be verified at all times during placement.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | 842030 |
| Inner diameter | 3 mm |
| Type | Magill, without cuff and without Murphy eye |
| Material | Medical grade (transparent PVC), flexible and durable |
| Connector | 15 mm standard (ISO 5356-1) |
| Radiopacity | Radiopaque contrast line for imaging guidance |
| Latex | Free of natural rubber latex |
| Function | Maintain a patent, direct airway without obstructions or deviations |
| Clinical application | Neonatal intubation or extremely small airways |
| Use environments | NICU, paediatric operating theatres and emergency departments |
| Presentation | Box of 10 units |
| Use | Disposable, single-use |
The ENDOSID Magill family without cuff and without Murphy eye covers a complete range of calibres for neonatal and paediatric intubation:
| Gauge | Reference |
|---|---|
| 2 mm | 842020 |
| 2.5 mm | 842025 |
| 3 mm | 842030 |
| 3.5 mm | 842035 |
| 4 mm | 842040 |
| 4.5 mm | 842045 |
| 5 mm | 842050 |
| 5.5 mm | 842055 |
| 6 mm | 842060 |
4. Equivalences and Cross-References
This tube is part of the ENDOSID airway management family from Cahnos, with a Magill design, without cuff and without Murphy eye. As complementary references in the same 3 mm calibre: the version with Murphy eye corresponds to Ref. 843030, the version with cuff and Murphy eye to Ref. 841030, and the standard Magill tube to Ref. 840030. The standard 15 mm connector complies with ISO 5356-1, so the device is compatible with virtually all circuits and ventilators on the market and can be replaced by cuffless neonatal endotracheal tubes of identical calibre and configuration from other manufacturers. For rapid intubation settings, the family also includes emergency kits (845xxx series) that integrate this type of tube with the essential accessories. Always verify the calibre and configuration (with or without cuff and with or without Murphy eye) before replacing one reference with another.
5. Selection tips and variants of interest
The calibre selection should be based on the patient’s age and weight: for neonates and premature infants, calibres of 2 to 3.5 mm are used; for infants and young children, calibres of 3.5 to 5 mm; and for older children or narrow airways, calibres of 5.5 to 6 mm. This version without Murphy eye is particularly indicated when a completely smooth and continuous internal lumen is desired; if distal obstruction by secretions or kinking is anticipated, consider the version with Murphy eye (Ref. 843030). In long-duration procedures or when an airtight airway seal is required, consider the cuffed variant of the same family (Ref. 841030). To complete your equipment, ENDOSID also offers intubation stylets and emergency kits in all calibres. Consult our technical-commercial team for the approval of references and high-volume orders.