Description
1. Introduction
The Endotracheal Tube ENDOSID Magill without cuff and without Murphy eye of 2 mm (Ref. 842020) is a single-use medical device designed for safe airway management in neonates, premature infants and patients with extremely reduced airway calibre. It is part of the ENDOSID family from Cahnos and offers the anaesthesia, intensive care and emergency professional a precise, reliable and easy-to-handle solution in the most demanding environments, such as the neonatal intensive care unit (NICU) and the paediatric operating theatre. Its minimalist design allows delicate and controlled insertion, ideal in contexts where every millimetre counts.
2. Technical explanation
The endotracheal tube is inserted into the trachea to ensure a patent airway and allow mechanical ventilation or administration of anaesthesia. The Magill configuration, with its characteristic proximal curvature, facilitates insertion in small-sized patients and allows the tip to be directed towards the glottic slit with greater control. As it has no inflation cuff, sealing is achieved by the natural fit of the calibre against the tracheal mucosa, which minimises the risk of pressure injury in immature airways and avoids compression of the mucosa. The absence of a Murphy eye guarantees a completely smooth and continuous internal lumen, with no elements that could trap secretions or interfere with airflow, providing a direct and undeviated passage. Its transparent material allows the patency of the circuit to be verified at all times during placement, and its atraumatic tip with radiopaque marking facilitates radiographic position control.
3. Technical Specifications
The technical features of the Endotracheal Tube ENDOSID Magill without cuff and without Murphy eye of 2 mm are summarised in the following table:
| Parameter | Specification |
|---|---|
| Reference | 842020 |
| Inner diameter | 2 mm |
| Type | Magill, without cuff and without Murphy eye |
| Murphy eye | No |
| Inflation cuff | No |
| Material | Medical grade, transparent, flexible and durable, latex-free |
| Tip | Atraumatic |
| Radiopaque marking | Yes, contrast band for radiographic control |
| Connector | 15 mm standard (ISO 5356-1) |
| Function | Maintain a direct airway, without obstructions or deviations |
| Clinical application | Neonatal intubation or extremely small airways |
| Use environments | NICU, paediatric operating theatres and emergency departments |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 10 units in individual sterile packaging |
| Use | Disposable, single-use |
4. Equivalences and Cross-References
This tube is part of the ENDOSID airway management family from Cahnos. In the same Magill series without cuff and without Murphy eye, the following calibres are available: 2.5 mm (Ref. 842025), 3 mm (Ref. 842030), 3.5 mm (Ref. 842035), 4 mm (Ref. 842040), 4.5 mm (Ref. 842045), 5 mm (Ref. 842050), 5.5 mm (Ref. 842055) and 6 mm (Ref. 842060), all with the same design. As complementary references of the same 2 mm calibre: the version with Murphy eye corresponds to Ref. 843020, the version with cuff and Murphy eye to Ref. 841020, the standard Magill tube to Ref. 840020 and, for rapid intubation environments, the 2 mm emergency kit (Ref. 845020) integrates this device with the essential accessories. With a standard 15 mm connector according to ISO 5356-1, it is replaceable by neonatal endotracheal tubes without cuff of identical calibre from other manufacturers, such as reference 44.000.11.020 of Magill tube without cuff of 2.0 mm. It is always recommended to verify the calibre and configuration (with or without cuff and with or without Murphy eye) before replacing one reference with another.
5. Selection tips and variants of interest
The selection of the calibre should be based on the patient’s age and weight: for neonates and premature infants, calibres of 2 to 3.5 mm are used; for infants and young children, calibres of 3.5 to 5 mm; and for older children or narrow airways, calibres of 5.5 to 6 mm. This version without Murphy eye is especially indicated when a completely smooth and continuous internal lumen is desired; if there is a risk of distal obstruction due to secretions or kinking, consider the version with Murphy eye (Ref. 843020). In long-duration procedures or when a tight airway seal is required, consider the cuffed variant of the same family (Ref. 841020). To complete its provision, ENDOSID also offers intubation guide stylets and emergency kits in all calibres. Consult our technical-commercial team for the approval of references and large-volume orders.



Reviews
There are no reviews yet.