Endotracheal Tube with Cuff and Murphy Eye for a Safe Airway
The Endosid endotracheal tube with cuff and Murphy eye of 5 mm is an essential device in anaesthetic trolleys, emergency care and critical care. It allows maintaining a patent and controlled airway during mechanical ventilation, offering effective sealing and reliable placement in each procedure. A trusted ally for anaesthesiology, intensive care and emergency teams.
Technical Explanation of the Device
This tube is inserted into the trachea through the orotracheal route and acts as an interface between the patient and the ventilator or ventilation system. The low-pressure balloon (cuff) is inflated via the pilot valve to seal the trachea, minimising air leaks and the risk of aspiration, while the Murphy eye (distal lateral orifice) ensures ventilation even if the distal end were occluded by the tracheal wall or secretions. Its 5 mm calibre makes it especially suitable for paediatric patients or adults with narrow airways, and its atraumatic design facilitates both intubation and extubation. It is a single-use product that prevents cross-contamination.
Technical Specifications
| Characteristic | Specification |
|---|---|
| Size (internal diameter) | 5 mm |
| Type | With balloon (low-pressure cuff) and Murphy eye |
| Material | Transparent medical PVC, latex-free |
| Proximal connector | Standard 15 mm (compatible with ventilation circuits and ventilators) |
| Murphy eye | Yes, distal lateral anti-pinch orifice |
| Balloon / cuff | Low pressure, inflated via pilot valve with indicator balloon |
| Use | Single-use (disposable), supplied sterile |
| Application | Intubation procedures in anaesthesia, emergency care and intensive care |
| Indicated patient | Small airways (paediatric and low-calibre patients) |
| Function | Ensures a clear airway and secure sealing during ventilation |
| Presentation | Box (price per box) |
Equivalences and Cross References
This tube belongs to the Endosid range of endotracheal tubes with cuff and Murphy eye, available in different calibres to cover the full range of patients (refs. 841030, 841035, 841040, 841045, 841050, 841060, 841065, 841075, 841085, 841090…). As a reference from the same family without cuff, the Endosid Magill tubes can be consulted (refs. 840035, 840040, 840050…). On the market, this type of 5 mm tube with cuff and Murphy eye accepts equivalences with references such as PB-212050U (suction line, size 5) from the ISSO PRO-BREATHE catalogue, or refs. 44.000.30.050 / 44.000.21.050 of sterile endotracheal tubes with cuff from Dahlhausen. Always verify the connector standard and material before replacing a usual reference.
Selection Tips and Variants of Interest
- Calibre selection: the internal diameter is selected according to the patient’s age and size. The 5 mm calibre is common in the paediatric population and in small-diameter airways; for adults, calibres from 7.0 to 9.0 mm are recommended.
- Balloon check: before intubation, verify the integrity of the cuff and pilot valve by inflating and deflating the balloon.
- Pressure control: use a manometer to keep the cuff pressure within the recommended range and avoid damage to the tracheal mucosa (pressure below 25-30 cmH2O).
- Variants: if you need subglottic suction, consider the range with suction cannula; if you prefer a tube without cuff, consult the Endosid Magill range. We recommend having several calibres in stock to respond to any patient.