Description
1. Introduction
The Contiplex® D Set from B. Braun brings together in a single set all the components needed to perform continuous anaesthesia of plexuses and peripheral nerves (cPNB): stimulation needle, introducer cannula, perineural catheter and connection and infusion system. Designed for anaesthesiology departments, pain units and enhanced recovery protocols (ERAS), it allows the target structure to be located using neurostimulation and/or ultrasound imaging and a stable local anaesthetic infusion line to be left in place for prolonged postoperative analgesia, with lower doses and reduced opioid consumption. A technical benchmark in continuous blockade, available in several sizes to suit each approach.
2. Technical explanation of the equipment and procedure
The set is based on the catheter-through-cannula technique: the Contiplex® D needle, fully insulated and with the electrode concentrated at the tip, is connected to the neurostimulator via the cable integrated into the ergonomic green translucent hub. Once the optimal motor response is located, the Teflon cannula (Contiplex® cannula) with radiopaque contrast lines is advanced, the needle is removed and the Contiplex® catheter is introduced through the cannula to the target plexus or nerve. The catheter, made of pure polyamide, has an open distal end, an integrated radiopaque line and position marks between 5 and 15 cm.
The infusion system is completed with the Perifix® catheter connector (crocodile type, flat and threadless), the flat Perifix® filter of 0.2 µm with resistance up to 7 bars, the Perifix® PinPad with hypoallergenic adhesive fixation and the 5 ml Omnifix® Luer-Lock syringe for injection and aspiration. It also includes a catheter identification label and an introducer guide.
3. Technical Specifications
| Product type | Continuous peripheral nerve block set (cPNB) – stimulation needle |
| Application | Continuous anaesthesia of plexuses and peripheral nerves (cPNB) |
| Contiplex® D needle | 15° and/or 30° bevel; graduated every 1 cm; ergonomic green translucent hub with cable for neurostimulator and local anaesthetic administration line |
| Needle gauge | 18 G (Ø 1.30 mm) or 20 G (Ø 1.10 mm) |
| Needle lengths | 55 mm, 80 mm and 110 mm |
| Contiplex® cannula | Plastic Teflon cannula with integrated contrast lines detectable by X-ray |
| Contiplex® catheter | Transparent, made of pure polyamide (PA); open distal end; marks between 5 and 15 cm; integrated radiopaque line; with introducer guide |
| Catheter calibre | 20 G (Ø ext. 0.85 mm / Ø int. 0.45 mm) or 24 G (Ø ext. 0.71 mm / Ø int. 0.41 mm) |
| Catheter length | 400 mm (for 55 mm needles) or 1000 mm (for 80 and 110 mm needles) |
| Catheter holes | Central opening |
| Catheter connector | Perifix®, crocodile type, tunnelled, threadless, ergonomic and flat |
| Filter | Perifix® flat, pore size 0.2 µm, priming volume 0.45 ml, resistance up to 7 bars |
| Fixation | Perifix® PinPad, hypoallergenic adhesive |
| Syringe included | 1 x Omnifix® 5 ml, Luer-Lock, for injection and aspiration |
| Packaging | Blister |
| Contains PVC | Yes |
| Contains latex | No |
| Contains DEHP | No |
| Use | Single-use |
| Sterility | Sterile – ethylene oxide (EO) |
| Presentation | Box of 10 units |
Available references (sold in boxes of 10 units)
| Reference | Description | Needle | Catheter | Presentation |
| 4898305 / BBR4898305 | SET CONTIPLEX D 55 MM 15º | 18 G – Ø 1.30 mm – 55 mm – 15° bevel | 20 G – Ø 0.85/0.45 mm – 400 mm – PA | Box of 10 units |
| 4898335 / BBR4898335 | SET CONTIPLEX D 55 MM 30º | 18 G – Ø 1.30 mm – 55 mm – 30° bevel | 20 G – Ø 0.85/0.45 mm – 400 mm – PA | Box of 10 units |
| 4898325 / BBR4898325 | SET CONTIPLEX D 1.1 x 55 MM 15º 20G | 20 G – Ø 1.10 mm – 55 mm – 15° bevel | 24 G – Ø 0.71/0.41 mm – 400 mm – PA | Box of 10 units |
| 4898308 / BBR4898308 | SET CONTIPLEX D 1.3 x 80 MM 15º | 18 G – Ø 1.30 mm – 80 mm – 15° bevel | Catheter for 80 mm needles (length 1000 mm) | Box of 10 units |
| 4898311 / BBR4898311 | SET CONTIPLEX D (80/110 mm variant) | See technical data sheet | See technical data sheet | Box of 10 units |
| 4898323 / BBR4898323 | SET CONTIPLEX D (variant) | See technical data sheet | See technical data sheet | Box of 10 units |
4. Equivalences and Cross-References
Within the Contiplex® family from B. Braun, the Contiplex® D sets are the classic continuous blockade sets using the cannula/catheter technique guided by neurostimulation. The Contiplex® D cannula is also sold individually (refs. 4898205 15° bevel, 4898235 30° bevel and 4898211 of 110 mm). Later generation sets share Perifix® components but use a different placement technique:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Observations |
| B. Braun | Contiplex® C Set | 4898115 / BBR4898115 | Comparable by category (not interchangeable 1:1) | Catheter-over-needle system (25 G); different placement technique. |
| B. Braun | Set Contiplex® S Ultra 360 | 4898650-01 / 4898610-01 / 4898615-01 (and -27) | Comparable by category (not interchangeable 1:1) | Catheter through 18 G needle, 360° echogenic needle, ultra catheter. |
| B. Braun | Set Contiplex® Tuohy Ultra 360 | 4898704-01 / 4898705-01 / 4898710-01 / 4898715-01 | Comparable by category (not interchangeable 1:1) | Catheter through needle with Tuohy bevel and 360° echogenic needle. |
| B. Braun | Contiplex® D cannula (component) | 4898205 / 4898235 / 4898211 | System component (not equivalent to a complete set) | Individual cannula for replacement; boxes of 25 units. |
| Teleflex (Arrow) | StimuCath™ Continuous Peripheral Nerve Block Set | AB-19608-S | Comparable by category (not interchangeable 1:1) | Complete continuous blockade system; verify configuration and references. |
There is no equivalence table officially validated by the manufacturer for cross-referencing these references with other brands; the correspondences are offered only as guidance by category. Before any substitution in tenders or for an alternative brand, consult the technical department to verify gauges, lengths, bevel and connector compatibility.
5. Selection tips and variants of interest
- Choice of bevel (15° vs. 30°): the 15° bevel offers finer sliding, preferred for superficial approaches; the 30° bevel facilitates passage through cutaneous planes and denser tissues. Ref. 4898305/4898325 (15°) and 4898335 (30°).
- Needle gauge: 18 G (Ø 1.30 mm) for most blocks; 20 G (Ø 1.10 mm, ref. 4898325) for less trauma with a 24 G fine catheter.
- Length according to depth: the 55 mm needle covers brachial plexus, femoral and superficial approach nerves; the 80 and 110 mm needles are reserved for deep blocks or patients with more adipose tissue, with a 1000 mm catheter.
- Guidance: the set is prepared for neurostimulation and can be combined with ultrasound imaging; for optimal needle-neurostimulator contact, the manufacturer recommends combining products from the same brand (Stimuplex series).
- Single-use: sterile single-use product; check the integrity of the packaging and the expiry date before each procedure. It is marketed in boxes of 10 units.