We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Contiplex® D Set from B. Braun – Continuous peripheral nerve block (cPNB) with 18/20 G stimulation needle, Teflon cannula and polyamide perineural catheter (box of 10 units)

Price range: 432,51 € through 640,77 €

Contiplex® D Set from B. Braun for continuous regional anaesthesia of plexuses and peripheral nerves, guided by neurostimulation and/or ultrasound imaging. Includes insulated needle with 15° or 30° bevel and connection hub to the neurostimulator, radiopaque Teflon capillary cannula, polyamide catheter with guide and depth markings (400 or 1000 mm), Perifix® flat connector, 0.2 µm filter, Perifix® PinPad, identification label and 5 ml Omnifix® syringe. Sterile (EO), single-use, latex-free and DEHP-free. References 4898305, 4898335, 4898325, 4898308, 4898311 and 4898323. Sold in boxes of 10 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BBR-SET-CONTIPLEX-D

Description

1. Introduction

The Contiplex® D Set from B. Braun brings together in a single set all the components needed to perform continuous anaesthesia of plexuses and peripheral nerves (cPNB): stimulation needle, introducer cannula, perineural catheter and connection and infusion system. Designed for anaesthesiology departments, pain units and enhanced recovery protocols (ERAS), it allows the target structure to be located using neurostimulation and/or ultrasound imaging and a stable local anaesthetic infusion line to be left in place for prolonged postoperative analgesia, with lower doses and reduced opioid consumption. A technical benchmark in continuous blockade, available in several sizes to suit each approach.

2. Technical explanation of the equipment and procedure

The set is based on the catheter-through-cannula technique: the Contiplex® D needle, fully insulated and with the electrode concentrated at the tip, is connected to the neurostimulator via the cable integrated into the ergonomic green translucent hub. Once the optimal motor response is located, the Teflon cannula (Contiplex® cannula) with radiopaque contrast lines is advanced, the needle is removed and the Contiplex® catheter is introduced through the cannula to the target plexus or nerve. The catheter, made of pure polyamide, has an open distal end, an integrated radiopaque line and position marks between 5 and 15 cm.

The infusion system is completed with the Perifix® catheter connector (crocodile type, flat and threadless), the flat Perifix® filter of 0.2 µm with resistance up to 7 bars, the Perifix® PinPad with hypoallergenic adhesive fixation and the 5 ml Omnifix® Luer-Lock syringe for injection and aspiration. It also includes a catheter identification label and an introducer guide.

3. Technical Specifications

Product type Continuous peripheral nerve block set (cPNB) – stimulation needle
Application Continuous anaesthesia of plexuses and peripheral nerves (cPNB)
Contiplex® D needle 15° and/or 30° bevel; graduated every 1 cm; ergonomic green translucent hub with cable for neurostimulator and local anaesthetic administration line
Needle gauge 18 G (Ø 1.30 mm) or 20 G (Ø 1.10 mm)
Needle lengths 55 mm, 80 mm and 110 mm
Contiplex® cannula Plastic Teflon cannula with integrated contrast lines detectable by X-ray
Contiplex® catheter Transparent, made of pure polyamide (PA); open distal end; marks between 5 and 15 cm; integrated radiopaque line; with introducer guide
Catheter calibre 20 G (Ø ext. 0.85 mm / Ø int. 0.45 mm) or 24 G (Ø ext. 0.71 mm / Ø int. 0.41 mm)
Catheter length 400 mm (for 55 mm needles) or 1000 mm (for 80 and 110 mm needles)
Catheter holes Central opening
Catheter connector Perifix®, crocodile type, tunnelled, threadless, ergonomic and flat
Filter Perifix® flat, pore size 0.2 µm, priming volume 0.45 ml, resistance up to 7 bars
Fixation Perifix® PinPad, hypoallergenic adhesive
Syringe included 1 x Omnifix® 5 ml, Luer-Lock, for injection and aspiration
Packaging Blister
Contains PVC Yes
Contains latex No
Contains DEHP No
Use Single-use
Sterility Sterile – ethylene oxide (EO)
Presentation Box of 10 units

Available references (sold in boxes of 10 units)

Reference Description Needle Catheter Presentation
4898305 / BBR4898305 SET CONTIPLEX D 55 MM 15º 18 G – Ø 1.30 mm – 55 mm – 15° bevel 20 G – Ø 0.85/0.45 mm – 400 mm – PA Box of 10 units
4898335 / BBR4898335 SET CONTIPLEX D 55 MM 30º 18 G – Ø 1.30 mm – 55 mm – 30° bevel 20 G – Ø 0.85/0.45 mm – 400 mm – PA Box of 10 units
4898325 / BBR4898325 SET CONTIPLEX D 1.1 x 55 MM 15º 20G 20 G – Ø 1.10 mm – 55 mm – 15° bevel 24 G – Ø 0.71/0.41 mm – 400 mm – PA Box of 10 units
4898308 / BBR4898308 SET CONTIPLEX D 1.3 x 80 MM 15º 18 G – Ø 1.30 mm – 80 mm – 15° bevel Catheter for 80 mm needles (length 1000 mm) Box of 10 units
4898311 / BBR4898311 SET CONTIPLEX D (80/110 mm variant) See technical data sheet See technical data sheet Box of 10 units
4898323 / BBR4898323 SET CONTIPLEX D (variant) See technical data sheet See technical data sheet Box of 10 units

4. Equivalences and Cross-References

Within the Contiplex® family from B. Braun, the Contiplex® D sets are the classic continuous blockade sets using the cannula/catheter technique guided by neurostimulation. The Contiplex® D cannula is also sold individually (refs. 4898205 15° bevel, 4898235 30° bevel and 4898211 of 110 mm). Later generation sets share Perifix® components but use a different placement technique:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Observations
B. Braun Contiplex® C Set 4898115 / BBR4898115 Comparable by category (not interchangeable 1:1) Catheter-over-needle system (25 G); different placement technique.
B. Braun Set Contiplex® S Ultra 360 4898650-01 / 4898610-01 / 4898615-01 (and -27) Comparable by category (not interchangeable 1:1) Catheter through 18 G needle, 360° echogenic needle, ultra catheter.
B. Braun Set Contiplex® Tuohy Ultra 360 4898704-01 / 4898705-01 / 4898710-01 / 4898715-01 Comparable by category (not interchangeable 1:1) Catheter through needle with Tuohy bevel and 360° echogenic needle.
B. Braun Contiplex® D cannula (component) 4898205 / 4898235 / 4898211 System component (not equivalent to a complete set) Individual cannula for replacement; boxes of 25 units.
Teleflex (Arrow) StimuCath™ Continuous Peripheral Nerve Block Set AB-19608-S Comparable by category (not interchangeable 1:1) Complete continuous blockade system; verify configuration and references.

There is no equivalence table officially validated by the manufacturer for cross-referencing these references with other brands; the correspondences are offered only as guidance by category. Before any substitution in tenders or for an alternative brand, consult the technical department to verify gauges, lengths, bevel and connector compatibility.

5. Selection tips and variants of interest

  • Choice of bevel (15° vs. 30°): the 15° bevel offers finer sliding, preferred for superficial approaches; the 30° bevel facilitates passage through cutaneous planes and denser tissues. Ref. 4898305/4898325 (15°) and 4898335 (30°).
  • Needle gauge: 18 G (Ø 1.30 mm) for most blocks; 20 G (Ø 1.10 mm, ref. 4898325) for less trauma with a 24 G fine catheter.
  • Length according to depth: the 55 mm needle covers brachial plexus, femoral and superficial approach nerves; the 80 and 110 mm needles are reserved for deep blocks or patients with more adipose tissue, with a 1000 mm catheter.
  • Guidance: the set is prepared for neurostimulation and can be combined with ultrasound imaging; for optimal needle-neurostimulator contact, the manufacturer recommends combining products from the same brand (Stimuplex series).
  • Single-use: sterile single-use product; check the integrity of the packaging and the expiry date before each procedure. It is marketed in boxes of 10 units.

Additional information

Brand

B. Braun

Application

cPNB

Bevel type

Quincke

Graduation

graduated every 1 cm

Packaging

Blister

Catheter holes

central opening

Filter priming volume

0.45 ml

Filter pore size

0.2 µm

Maximum pressure

7.0 bar

Syringes included

1 x Omnifix 5 ml – LL

Catheter connector included

Yes

PinPad included

Yes

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 10 units

Calibre (G)

18, 20

Longitud

55 mm, 80 mm, 110 mm, 33 mm

Ángulo del bisel

15 °, 30 °

Manufacturer

B. Braun Melsungen AG

Product type

Continuous peripheral nerve block set (cPNB) – stimulation needle

Needle

Contiplex® D, insulated, 15°/30° bevel, graduated every 1 cm

Needle gauge

18 G (Ø 1.30 mm) / 20 G (Ø 1.10 mm)

Needle length

55 mm / 80 mm / 110 mm

Cannula

Radiopaque Teflon cannula with contrast lines detectable by X-ray

Catheter material

Polyamide (PA)

Catheter calibre

20 G (Ø 0.85/0.45 mm) / 24 G (Ø 0.71/0.41 mm)

Catheter length

400 mm (55 mm needles) / 1000 mm (80 and 110 mm needles)

Catheter orifices

Central opening

Filter

Perifix® flat 0.2 µm, priming volume 0.45 ml, resistance 7 bars

Connector

Perifix® crocodile type, flat and threadless

Fixation system

Perifix® PinPad, hypoallergenic adhesive

Syringe included

Omnifix® 5 ml Luer-Lock

Contains PVC

Yes

Contains DEHP

No

Latex

Latex-free

Tipo uso

Single-use

Esterilidad

Sterile